| Plan Review Stops For Permit 19050028 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-20 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-20 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2020-09-15 12:38:40 | GENERATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | 4TH REVIEW - NO CHANGES SINCE THE 3RD REVIEW | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | THIS PERMIT IS FOR THE ROOFTOP GENERATOR FROM MASTER | | | PERMIT (160701) AND REVISION (18071460) | | | 1) PLEASE SHOW THE GENERATOR CONNECTION TO THE ROOFTOP | | | STAND ON THE SIGNED AND SEALED DRAWINGS. | | | 2) PLEASE PROVIDE SIGNED AND SEALED ROOFTOP SCREENING | | | DETAILS FROM AN ARCHITECT OR ENGINEER TO COMPLY WITH | | | THE WIND LOADS PER FBC 1609 (SHOW ALL ATTACHMENTS | | | (SIZE, TYPE AND LENGTH) TO BUILD IT AND TO FASTEN TO | | | THE ROOF STRUCTURE). | | | 3) DRAWING (E1.3) THE LOCATION OF THE GENERATOR IS NOT | | | THE SAME AS ALL OF THE OTHER DRAWINGS - PLEASE CLARIFY | | | THE LOCATION SHOULD BE THE SAME ON ALL OF THE DRAWINGS. | | | 4) DRAWINGS THAT ARE REVISIONS TO OTHER PERMIT NUMBERS | | | SHOULD BE REVISED UNDER A SEPERATE PERMIT NUMBER - NOT | | | AS PART OF THE GENERATOR PERMIT. | | | 5) WHAT ARE THE ORIGINAL PERMIT NUMBERS FOR DRAWINGS | | | (A-405R) AND (A-107R) ? | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-18 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-18 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2020-08-18 13:30:31 | GENERATOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | THIS PERMIT IS FOR THE ROOFTOP GENERATOR FROM MASTER | | | PERMIT (160701) AND REVISION (18071460) | | | 1) PLEASE SHOW THE GENERATOR CONNECTION TO THE ROOFTOP | | | STAND ON THE SIGNED AND SEALED DRAWINGS. | | | 2) PLEASE PROVIDE SIGNED AND SEALED ROOFTOP SCREENING | | | DETAILS FROM AN ARCHITECT OR ENGINEER TO COMPLY WITH | | | THE WIND LOADS PER FBC 1609 (SHOW ALL ATTACHMENTS | | | (SIZE, TYPE AND LENGTH) TO BUILD IT AND TO FASTEN TO | | | THE ROOF STRUCTURE). | | | 3) DRAWING (E1.3) THE LOCATION OF THE GENERATOR IS NOT | | | THE SAME AS ALL OF THE OTHER DRAWINGS - PLEASE CLARIFY | | | THE LOCATION SHOULD BE THE SAME ON ALL OF THE DRAWINGS. | | | 4) DRAWINGS THAT ARE REVISIONS TO OTHER PERMIT NUMBERS | | | SHOULD BE REVISED UNDER A SEPERATE PERMIT NUMBER - NOT | | | AS PART OF THE GENERATOR PERMIT. | | | 5) WHAT ARE THE ORIGINAL PERMIT NUMBERS FOR DRAWINGS | | | (A-405R) AND (A-107R) ? | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-13 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-13 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2020-07-13 12:15:55 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 1609 AND 107.2.1; PLEASE PROVIDE THE SIGNED AND | | | SEALED REQUIRED WIND LOAD RESISTANCE CALCS AND THE | | | ANCHORING DETAILS INCLUDING LOCATIONS FOR THE | | | GENERATOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-06-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-04 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-04 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2019-06-04 17:06:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. PROVIDE ENGINEERING FOR THE GENERATOR INSTALLATION | | | TO SHOW RESISTANCE TO WIND LOADS FBC B 1609. INCLUDE | | | WIND DESIGN CRITERIA. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-09 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-09 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2020-08-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-27 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-08-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-08-02 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-08-02 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2020-08-02 15:10:12 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | IS THIS A PLAN FOR A GENERATOR OR A REVISION THEY ARE | | | TWO SEPARATE ITEMS? PERMIT IS FOR A GENERATOR. | | | | | | PAGE SUBMITTED BY CONTRACTOR HAS TO BE STAMPED BY | | | ENGINEER OF RECORD. | | | | | | PAGE SUBMITTED BY CONTRACTOR HAS GENERATRO AT 45KW?? 45 | | | OT 70??? | | | | | | I ONLY WANT TO SEE GENERATOR RISER, LOAD CALC, AND | | | SPECS FOR THE GENERATOR AND THE TRANSFER SWITCH. ALL | | | OTHER SHEETS ( THE ONES THE ARE DATED 7/15 AND STATE | | | ENTIRE SHEET REVISION) TAKEN OUT AND SUBMITTED | | | SEPARATELY FOR A REVISION. | | | | | | WHEN SUBMITTING THE REVISION PLEASE SPELL OUT WHAT HAS | | | BEEN DONE FOR THE REVISION OTHERWISE IT TAKES LONGER TO | | | REVIEW. ENTIRE SHEET REVISED WILL PROBALBLY FAIL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-07-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-07-15 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-07-15 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2020-07-15 17:00:58 | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE OF PERMIT IN IN LINE WITH INDUSTRY | | | STANDARDS(19000) | | | | | | MARSHALL SWIFTS HAS GENERATOR AT $50,000 WITHOUT | | | TRANSFER SWITCH. | | | | | | PLEASE SEND A COPY OF THE CONTRACT FOR THE GENERATOR | | | SIGNED BY OWNER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-16 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-16 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2019-05-16 08:47:04 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE OF WORK TOO LOW. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | CAN NOT PROTECT 350S WITH A 400A BREAKER |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-07-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-07-10 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-06-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-06-05 |
Time |
10:40 |
Sent To |
I |
|
| Notes |
| 2019-06-05 10:46:53 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE NO LOCATIONS INDICATIONS SUBMITTED. | | | | | | PLEASE PROVIDE THE LOCATION OF THIS GENERATOR INCLUDING | | | ALL DIMENSIONS TO BUILDINGS, WINDOWS AND DOORS. | | | | | | | | | 2) THERE ARE NO INDICATIONS IF THIS GENERATOR WILL BE | | | PROVIDING POWER TO ANY LIFE SAFEY EQUIPMENT OR SYSTEMS. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 3) THERE ARE NO INDICATIONS OF COMPLIANCE WITH ANY FIRE | | | CODES. | | | | | | BASED ON # 2 ABOVE IT MAY NEED TO COMPLY WITH BOTH NFPA | | | 110 AND 37 AS WELL AS OTHER APPLICABLE FIRE CODES. | | | | | | PLEASE PROVIDE ZCODE COMPLIANCE NOTES | | | | | | | | | 4) THERE ARE NO FOUNDATION DETAILS. | | | | | | PLEASE PROVIDE DETAILS, INCLUDING LOCATION, DIMENSIONS, | | | TIE-DOWNS, ETC. | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-16 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-16 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2020-07-16 12:37:47 | THE GAS PLANS FOR THE RESTAURANT AND GENERATOR WERE | | | APPROVED UNDER MASTER PERMIT-17020359, AND | | | REVISION-18071140. THE GAS INSPECTIONS WERE COMPLETED | | | AND APPROVED UNDER SUB-PERMIT- 19031051. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2019-05-14 13:33:05 | APPROVED UNDER GAS PERMIT #17020359***REVISION | | | #18071140 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-20 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-08 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-09-17 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-08-26 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-18 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-07-30 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-07-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-07-09 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-06-05 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-05-01 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2019-06-04 17:07:07 | TO FIRE | | | | | 2019-05-14 10:58:31 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 5/14/19 EL | | 2019-05-02 11:26:33 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-07-31 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-07-31 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-07-31 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-07-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-07-16 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-07-16 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2020-07-16 12:55:28 | 1ST REVIEW FBC-2017 PLUMBING | | | PERMIT-19050028 | | | 7/16/2020 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT REVISED PLUMBING PLANS CORRESPONDING TO THE | | | REVISED BAR LAYOUT SHOWN ON SHEET A-405R- SECTION | | | 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-20 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-20 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-15 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2020-09-15 12:39:31 | THE ELECTRICAL DRAWINGS = SIGNED AND SEALED DRAWINGS | | | AND DOCUMENTS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS AND DOCUMENTS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER OR ARCHITECT DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-08-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-08-18 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-08-18 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2020-08-18 14:57:03 | THE ELECTRICAL DRAWINGS = SIGNED AND SEALED DRAWINGS | | | AND DOCUMENTS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS AND DOCUMENTS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ENGINEER OR ARCHITECT DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-07-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-07-13 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-07-13 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-10-09 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-10-09 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2020-09-16 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-09-16 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-09-16 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2020-09-16 08:58:32 | REPEAT COMMENT: | | | | | | COMMENT RESPONSE REFERENCES SHEET 105-R FOR GENERATOR | | | SCREENING. SHEET 105-R IS NOT WITHIN THE UPLOADED | | | DOCUMENTS | | | | | | PLEASE UPLOAD SHEET. NEEDS TO SHOW SCREENING OF ALL | | | ROOF MOUNTED EQUIPMENT TO HEIGHT OF MECHANICAL | | | EQUIPMENT/GENERATOR | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-08-05 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-08-05 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-08-05 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2020-08-05 10:19:37 | REPEAT COMMENT: | | | | | | COMMENT RESPONSE REFERENCES SHEET 105-R FOR GENERATOR | | | SCREENING. SHEET 105-R IS NOT WITHIN THE UPLOADED | | | DOCUMENTS | | | | | | PLEASE UPLOAD SHEET. NEEDS TO SHOW SCREENING OF ALL | | | ROOF MOUNTED EQUIPMENT TO HEIGHT OF MECHANICAL | | | EQUIPMENT/GENERATOR | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-07-14 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2020-07-14 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2020-07-14 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2020-07-14 14:26:46 | GENERATOR SHALL BE SCREENED TO HEIGHT OF EQUIPMENT - | | | PLEASE PROVIDE CLEAR DETAIL OF SCREENING | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-05-14 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-05-14 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2019-05-14 10:58:13 | IS THE GENERATOR ROOF MOUNTED? NEED TO PROVIDE | | | INFORMATION ON LOCATION. IF ROOF MOUNTED, PLEASE SHOW | | | LOCATION ON AERIAL VIEW OR SURVEY. PLEASE PROVIDE | | | INFORMATION ON PROPOSED SCREENING, TO BE AS TALL AS THE | | | GENERATOR. | | | | | | IF GROUND MOUNTED, PLEASE SHOW LOCATION ON SURVEY OR | | | SITE PLAN AND WITH SITE PICTURES. | | | PLEASE INDICATE IF LANDSCAPING IS BEING REMOVED. PLEASE | | | INDICATE DIMENSIONS OF SETBACKS FROM BACK OF CURB- | | | GENERATORS CANNOT PROJECT MORE THAN FOUR FEET INTO A | | | SETBACK. | | | | | | IF GROUND MOUNTED, EQUIPMENT SHALL NEED TO BE SCREENED | | | AS FOLLOWS: GENERATOR SHALL BE LANDSCAPED WITH SHRUBS | | | AND HEDGES AT SUFFICIENT HEIGHT TO SCREEN | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | [email protected] | | | 561 822 1426 | | | | | | |
|
|