Plan Review Details - Permit 19041536
| Plan Review Stops For Permit 19041536 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-09 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-09 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2019-05-09 13:47:58 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PERMIT APPLICATION UNDER DESCRIPTION OF WORK AS TUB | | | TO SHOWER CONVERSION. PLAN SHOWS THE WATER HEATER TO BE | | | RELOCATED FOR THE SHOWER. PLEASE CLARIFY WHERE IS THE | | | TUB? FBC 107.2.1 | | | | | | 2. PLEASE SEE PLUMBING COMMENTS, THEY APPLY TO BUILDING | | | AS WELL. PLEASEE ADDRESS THEM. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-09 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-30 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2019-05-01 15:12:03 | BLDG MISC 2 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-08 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-08 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
| 2019-05-08 16:23:28 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) PERMIT APPLICATION UNDER DESCRIPTION OF WORK AS TUB | | | TO SHOWER CONVERSION. PLAN SHOWS THE WATER HEATER TO BE | | | RELOCATED FOR THE SHOWER. PLEASE CLARIFY WHERE IS THE | | | TUB? FBC 107.2.1 | | | | | | 2) PROVIDE DETAIL OF WATER HEATER ENCLOSURE. FBC | | | 107.2.1 | | | | | | 3) PROVIDE DIMENSION'S OF BATHROOM SHOWING DISTANCE'S | | | BETWEEN FIXTURES AND DIMENSION OF SHOWER. SHOWER SHALL | | | BE MIN 900 SQ INCHES. FBC-R P2705.1 #5, P2708.1 | | | | | | 4) PROVIDE SANITARY ISOMETRIC DRAWING. FBC 107.3.5 | | | | | | 5) ELC PLAN AND PERMIT REQUIRED FOR WATER HEATER | | | RELOCATION. FBC 105.1 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
|