Plan Review Details - Permit 19041487
Plan Review Stops For Permit 19041487
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-30 Cont ID  
Sent By tklarge Date 2019-08-30 Time 11:34 Rev Time 0.00
Received By tklarge Date 2019-08-27 Time 15:02 Sent To  
Notes
2019-08-27 15:02:45RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-15 Cont ID  
Sent By tklarge Date 2019-08-15 Time 10:42 Rev Time 0.00
Received By tklarge Date 2019-08-13 Time 13:26 Sent To  
Notes
2019-08-14 13:26:43RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-02 Cont ID  
Sent By thunt Date 2019-05-02 Time 10:25 Rev Time 0.00
Received By thunt Date 2019-04-30 Time 14:31 Sent To  
Notes
2019-05-01 14:31:50ROUTED TO PLUMBING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-08-30 Cont ID  
Sent By tklarge Date 2019-08-30 Time 11:34 Rev Time 0.00
Received By tklarge Date 2019-08-30 Time 06:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-08-15 Cont ID  
Sent By tklarge Date 2019-08-15 Time 10:42 Rev Time 0.00
Received By tklarge Date 2019-08-15 Time 08:28 Sent To  
Notes
2019-08-15 10:42:021) THERE ARE TWO DIFFERENT SETS OF PLANS IN THIS
 SUBMITTAL PACKAGE. ONE SET IS FROM FARMER & IRWIN AND
 THE OTHER IS FROM GENERAL PLUMBING. REMOVE ALL OLD
 PLANS AND DOCUMENTS FROM THIS SUBMITTAL AND SUBMIT TWO
 COPIES OF THE PLANS TO BE USED. WPB AMEND. TO FBC SEC.
 107.2.1.
 2) THE WATER RISER SUBMITTED FROM GENERAL PLUMBING
 DIFFICULT TO SEE SOME OF THE PIPE SIZE. SUBMIT TWO
 COPIES OF AN EXPANDED LEGIBLE PLAN FOR REVIEW. WPB
 AMEND. TO FBC SEC. 107.2.1.
 3) SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR
 THE PEX PIPE.2017 FBC-PLUMBING SEC. 303.2.
 4) HOW WILL THE PIPING BE PROTECTED FROM UV RAYS?
 SUBMIT INFORMATION ON THE PLANS. WPB AMEND. TO FBC SEC.
 107.2.1.
 5) ONE SPECIFICATION SHEET THAT WAS SUBMITTED WHICH HAS
 SEVERAL SPECIFICATIONS ON IT IS ILLEGIBLE.WPB AMEND. TO
 FBC SEC. 107.2.1.
 6) SUBMIT DOCUMENTATION THAT THE JM EAGLE FITTINGS ARE
 COMPATIBLE WITH THE PEX PIPING.
 7) TWO DIFFERENT SPECIFICATIONS HAVE BEEN SUBMITTTED
 FOR THE CLAMPS. WHICH ONES ARE BEING USED? CLARIFY.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-05-02 Cont ID  
Sent By thunt Date 2019-05-02 Time 10:25 Rev Time 0.00
Received By thunt Date 2019-05-02 Time 10:25 Sent To  
Notes
2019-05-02 10:25:53PLUMBING 1ST REVIEW**DENIED**NOTE - A STOP WORK ORDER
 WAS ISSUED FOR WORK STARTING BEFORE ISSUANCE OF PERMIT.
 A 4X PERMIT FEE HAS BEEN APPLIED TO THIS PERMIT. IF YOU
 WISH TO DISCUSS THE MATTER PLEASE CONTACT TIM LARGE
 CHIEF PLUMBING INSPECTOR @ 561-805-6692
  
 1) PIPING SHALL NOT BE INSTALLED WITH IN 5' OF U.V
 LIGHT. PER NOTES FROM THE FIELD INSPECTOR ALL PIPING IS
 INSTALLED IN DIRECT SUNLIGHT. PER THE MANUFACTURES
 INSTALLATION MANUAL 22.11.16 SECTION 3.2 (C) #2
  
 2) STRAPPING MATERIAL CALLED OUT ON PLAN IS NOT AN
 APPROVED METHOD AND MAY CUT INTO THE PIPING MATERIAL.
 PER THE MANUFACTURES INSTALLATION MANUAL 22.11.16 2.2
 (D) #2
  
 3) PROPOSAL INCLUSIONS # 3 CALLS OUT FOR WATER HEATER
 AS SPECIFIED. THERE IS NOT WATER HEATER OR HOT WATER
 PIPING SHOWN ON THE PLAN. PLEASE CLARIFY FBC 107.2.1.
  
 4) PIPING SHOWN ON PLAN APPEARS TO BE TIGHT AND
 STRAPPING METHOD WOULD NOT ALLOW FOR PROPER EXPANSION.
 PER THE MANUFACTURES INSTALLATION MANUAL
  
 5) PLANS SUBMITTED MUST BE SIGNED BY THE PERSON WHO
 DESIGNED THEM TAKING RESPONSIBILITY. F.A.C 471, 781,
 489
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]