Plan Review Details - Permit 19041487
| Plan Review Stops For Permit 19041487 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-30 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-27 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2019-08-27 15:02:45 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-15 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-13 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2019-08-14 13:26:43 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-02 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-30 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2019-05-01 14:31:50 | ROUTED TO PLUMBING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-08-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-30 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-30 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-15 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-15 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2019-08-15 10:42:02 | 1) THERE ARE TWO DIFFERENT SETS OF PLANS IN THIS | | | SUBMITTAL PACKAGE. ONE SET IS FROM FARMER & IRWIN AND | | | THE OTHER IS FROM GENERAL PLUMBING. REMOVE ALL OLD | | | PLANS AND DOCUMENTS FROM THIS SUBMITTAL AND SUBMIT TWO | | | COPIES OF THE PLANS TO BE USED. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 2) THE WATER RISER SUBMITTED FROM GENERAL PLUMBING | | | DIFFICULT TO SEE SOME OF THE PIPE SIZE. SUBMIT TWO | | | COPIES OF AN EXPANDED LEGIBLE PLAN FOR REVIEW. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 3) SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR | | | THE PEX PIPE.2017 FBC-PLUMBING SEC. 303.2. | | | 4) HOW WILL THE PIPING BE PROTECTED FROM UV RAYS? | | | SUBMIT INFORMATION ON THE PLANS. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 5) ONE SPECIFICATION SHEET THAT WAS SUBMITTED WHICH HAS | | | SEVERAL SPECIFICATIONS ON IT IS ILLEGIBLE.WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 6) SUBMIT DOCUMENTATION THAT THE JM EAGLE FITTINGS ARE | | | COMPATIBLE WITH THE PEX PIPING. | | | 7) TWO DIFFERENT SPECIFICATIONS HAVE BEEN SUBMITTTED | | | FOR THE CLAMPS. WHICH ONES ARE BEING USED? CLARIFY. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-02 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-02 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2019-05-02 10:25:53 | PLUMBING 1ST REVIEW**DENIED**NOTE - A STOP WORK ORDER | | | WAS ISSUED FOR WORK STARTING BEFORE ISSUANCE OF PERMIT. | | | A 4X PERMIT FEE HAS BEEN APPLIED TO THIS PERMIT. IF YOU | | | WISH TO DISCUSS THE MATTER PLEASE CONTACT TIM LARGE | | | CHIEF PLUMBING INSPECTOR @ 561-805-6692 | | | | | | 1) PIPING SHALL NOT BE INSTALLED WITH IN 5' OF U.V | | | LIGHT. PER NOTES FROM THE FIELD INSPECTOR ALL PIPING IS | | | INSTALLED IN DIRECT SUNLIGHT. PER THE MANUFACTURES | | | INSTALLATION MANUAL 22.11.16 SECTION 3.2 (C) #2 | | | | | | 2) STRAPPING MATERIAL CALLED OUT ON PLAN IS NOT AN | | | APPROVED METHOD AND MAY CUT INTO THE PIPING MATERIAL. | | | PER THE MANUFACTURES INSTALLATION MANUAL 22.11.16 2.2 | | | (D) #2 | | | | | | 3) PROPOSAL INCLUSIONS # 3 CALLS OUT FOR WATER HEATER | | | AS SPECIFIED. THERE IS NOT WATER HEATER OR HOT WATER | | | PIPING SHOWN ON THE PLAN. PLEASE CLARIFY FBC 107.2.1. | | | | | | 4) PIPING SHOWN ON PLAN APPEARS TO BE TIGHT AND | | | STRAPPING METHOD WOULD NOT ALLOW FOR PROPER EXPANSION. | | | PER THE MANUFACTURES INSTALLATION MANUAL | | | | | | 5) PLANS SUBMITTED MUST BE SIGNED BY THE PERSON WHO | | | DESIGNED THEM TAKING RESPONSIBILITY. F.A.C 471, 781, | | | 489 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | 561-248-2703 | | | [email protected] | | | [email protected] |
|
|
|