Plan Review Details - Permit 19041340
| Plan Review Stops For Permit 19041340 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-05-21 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-05-21 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2019-05-21 09:59:55 | ENERGY CALCULATIONS NEED TO BE SIGNED BY PREPARER AND | | | OWNER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-05-06 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-05-06 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2019-05-06 13:45:25 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 19041340 | | | REVIEWED: MAY 6, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1) 107.2.1FBC[AMENDED] ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | -PLEASE SIGN AND SEAL DRAWINGS | | | | | | 2) 103.1.1.2 FBC[RE] THE BUILDINGS OWNER, THE OWNERS | | | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED | | | BY THE OWNER SHALL CERTIFY THAT THE BUILDING IS IN | | | COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. 553.907, FLORIDA | | | STATUTES. | | | -PLEASE HAVE THE PERSON WHO PRODUCED AND THE OWNER | | | SIGN THE ENERGY CALCULATIONS. | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-29 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-05-29 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-15 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-15 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2019-05-15 15:10:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | | 107.1, 107.2.1, 107.3.5.1.2 | | | 2. PROVIDE NARRATIVE OF CHANGES FOR REVISION. CLOUDING | | | THE WHOLE ELECTRICAL PLAN AS A REVISION WITH NO | | | EXPLANATION IS NOT ACCEPTABLE. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-05 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-05 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-28 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-28 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2019-05-28 19:33:42 | 3RD REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: IN ORDER TO GET THE GAS PLAN | | | APPROVED I SUGGEST A MEETING PLEASE CONNECT ME TO SET | | | UP TIME AND DATE SEE INFO BELOW. | | | | | | 1. THE PLAN SHEETS SHALL MATCH SHT. P-1 SHOWS PE | | | UNDERGROUND GAS PIPING SHT. G-1 SHOWS A DIFFERENT TYPE | | | OF PIPING GMP IT ALSO DOES NOT SHOW FUTURE BBQ, THE | | | WATER HEATER IS NOT SHOWN IN SAME LOCATION. PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT G-1 LIST THE SYSTEM AS LP GAS IS THIS CORRECT IF | | | SO SHOW LOCATION OF LP TANK AND NOTE A SEPARATE PERMIT | | | IS REQUIRED FOR THE LP TANK. PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 3. PLEASE PROVIDE AN ABBREVIATION LEGEND I DO NOT | | | RECOGNIZE THESE GMP, IHWH, MBTUH, FUT. PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PLEASE CLARIFY ON PLAN IF PIPING IS RUNNING UNDER | | | GROUND, GALVANIZED SHALL NOT BE BURIED DIRECTLY UNDER | | | GROUND IT SHALL BE SLEEVED SHOW SLEEVE DETAIL ON PLAN. | | | PER FBC RES G2415.11, G2415.11.1 | | | | | | 5. NOTE ON THE PLANPLUMBING AND GAS SHALL COMPLY WITH | | | FLORIDA BUILDING CODE RESIDENTIAL 2017 6TH EDITION | | | | | | 6. 2ND REQUEST SUBMIT TWO COPIES OF THE MANUFACTURER?S | | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES. | | | SEC.G2408.1. | | | | | | 7. 2ND REQUEST SHOW TANKLESS HEATER MOUNTED A MIN OF | | | 4FT FROM OPERABLE OPENING IN BUILDING. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 8. A DRIP LEG IS REQUIRED AT EACH APPLIANCES PLEASE | | | SHOW ON PLAN. PER FBC RES G2419.4 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-05-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-17 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-17 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2019-05-17 16:42:00 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED WITH. | | | | | | | | | 1) A PARTIAL GAS PLAN HAS BEEN SUBMITTED WITH OUT A GAS | | | PERMIT AGAIN. GAS PERMIT IS REQUIRED AND THE FOLLOWING | | | COMMENTS BELOW NEED TO BE ADDRESSED. FBC 105.1 | | | | | | 2) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 3) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1. | | | | | | 4) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 5) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2 | | | | | | 6) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE RANGE/ | | | STOVE. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. 2017 FBC-FUEL | | | GAS SEC.304.9.3 OR FBCR G2407.9.3. | | | | | | 7) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | | | | 8) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE | | | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION | | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER | | | HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | | DRAWN. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | 9) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 10) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 11) BOTH THE WATER HEATER AND STOVE HAS GAS PIPE TO | | | THEM ON SHT. P-1 BUT ON SHT. E-1 ON THE PANEL SCHDULE | | | IT CALLS FOR BOTH AS ELEC POWER. PLEASE CLEARIFY. FBC | | | 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-30 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-30 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2019-04-30 16:20:02 | GAS 1ST REVISION REVIEW**DENIED** NONE OF THE PLANS | | | PROVIDE HAVE BEEN SIGN AND SEALED AS REQUIRED BY THE | | | DESIGN PROFESSIONAL. 61G1-16.001 ARCHITECT?S AND | | | INTERIOR DESIGNER?S SEAL. EACH ARCHITECT AND INTERIOR | | | DESIGNER SHALL ACQUIRE A SEAL WITH WHICH SHE OR HE | | | SHALL IDENTIFY ALL PLANS, SPECIFICATIONS OR REPORTS | | | PREPARED OR ISSUED BY HER OR HIM AND FILED FOR PUBLIC | | | RECORD. THE SEAL SHALL BE CAPABLE OF LEAVING A | | | PERMANENT INK REPRESENTATION OR OTHER FORM OF EMBOSSING | | | OR OPAQUE AND PERMANENT IMPRESSION, WHICH ALSO MAY BE | | | COMPUTER GENERATED IMPRESSIONS, ON THE SURFACE OF | | | PRINTS OR OTHER DUPLICATIONS OF DRAWINGS, AND, AS | | | APPROPRIATE, UPON SPECIFICATION PAGES, AND OTHER | | | ARTICLES OF SERVICE. | | | | | | | | | A CHANGE IN THE VALUE OF WORK NEEDS TO BE ADJUSTED FOR | | | THE REVISION CHANGES. | | | | | | 1) A PARTIAL GAS PLAN HAS BEEN SUBMITTED WITH OUT A GAS | | | PERMIT AGAIN. GAS PERMIT IS REQUIRED AND THE FOLLOWING | | | COMMENTS BELOW NEED TO BE ADDRESSED. FBC 105.1 | | | | | | 2) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2017 FBC-FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2017 FBC-RES SEC. | | | G2413.4.1, G2413.4.2. | | | | | | 3) SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1. | | | | | | 4) LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS | | | SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES | | | G2413.4 (1 ) THROUGH G2413.4 (21). | | | | | | 5) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2017 | | | FBC-FUEL GAS SEC.402.4.1, 402.4.2, OR 2017 FBC-RES. | | | SEC. G 2413.4.1, G2413.4.2 | | | | | | 6) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE RANGE/ | | | STOVE. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR. 2017 FBC-FUEL | | | GAS SEC.304.9.3 OR FBCR G2407.9.3. | | | | | | 7) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | | | | 8) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE | | | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION | | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER | | | HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | | DRAWN. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | 9) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 10) INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2017 FBC-FUEL GAS SEC.402.1, 402.4.3 | | | THRU 402.6 OR 2017 FBC RES. SEC. G2413.2, G2413.4.3. | | | | | | 11) BOTH THE WATER HEATER AND STOVE HAS GAS PIPE TO | | | THEM ON SHT. P-1 BUT ON SHT. E-1 ON THE PANEL SCHDULE | | | IT CALLS FOR BOTH AS ELEC POWER. PLEASE CLEARIFY. FBC | | | 107.2.1 | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | 561-248-2703 | | | [email protected] | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-06-05 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-05-30 |
Time |
05:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-05-16 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-25 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-05-30 |
Time |
05:50 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-06-05 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-25 |
Time |
04:49 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-05-25 |
Time |
04:42 |
Sent To |
|
|
| Notes |
| 2019-05-25 04:49:03 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED RETURN IN MASTER BEDROOM PER 2017 - FLORIDA | | | BUILDING CODE - RESIDENTIAL SEC. M1602.3 BALANCED | | | RETURN AIR. | | | | | | CHRIS MONTELLO | | | 805-6733 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-28 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-28 |
Time |
19:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-05-17 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-17 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-17 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2019-05-17 16:42:50 | SEE GAS COMMENTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-30 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-30 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2019-05-13 10:53:34 | SEE GAS COMMENTS |
|
|
|