Plan Review Details - Permit 19041261
| Plan Review Stops For Permit 19041261 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-29 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-29 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-05-06 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-05-06 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-05-06 14:31:58 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19041261 | | | ADD: 415 50TH ST. / BUILDING #3 / (3) DWELLING UNITS | | | CONT: PREMIER BUILDERS & DEVELOPMENT | | | TEL: 561-891-1607 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MAY MON. 06/2019 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET THE DESIGNER OF RECORD HAS NOT | | | INDICATED AS TO WHICH METHOD THE PLANS WERE DEVELOPED | | | UNDER THE 2017 FBC-EXISTING BUILDING CODE, SEE SECTION | | | 301.1. THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, | | | ADDITION OR RELOCATION OF ALL EXISTING BUILDINGS SHALL | | | COMPLY WITH ONE OF THE METHODS LISTED IN SECTIONS | | | 301.1.1 THROUGH 301.1.3 AS SELECTED BY THE APPLICANT. | | | SECTIONS 301.1.1 THROUGH 301.1.3 SHALL NOT BE APPLIED | | | IN COMBINATION WITH EACH OTHER. | | | | | | 301.1.1 PRESCRIPTIVE COMPLIANCE METHOD. | | | | | | 301.1.2 WORK AREA COMPLIANCE METHOD. | | | | | | 301.1.3 PERFORMANCE COMPLIANCE METHOD. | | | | | | 2) SHEET A1 : | | | | | | 2A) UNDER THE HEADING OF GENERAL NOTE # 07 THE PLAN | | | INDICATES WINDOW AND DOORS ARE TO BE REPLACED UNDER | | | SEPARATE PERMIT, TO DATE NO PERMIT HAS BEEN APPLIED | | | FOR. NOTE # 12 INDICATES THE EGRESS WINDOWS ARE LOCATED | | | AS SHOWN PER FBC-R 310. THIS IS A 3 DWELLING UNIT | | | BUILDING AND DOES NOT FALL UNDER THE 1 & 2 FAMILY | | | RESIDENTIAL CODE. THIS BUILDING FALLS UNDER THE 2017 | | | FBC-B. | | | | | | 2B) NOTE # 12 INDICATES THE EGRESS WINDOWS ARE LOCATED | | | AS SHOWN PER FBC-R 310, PLEASE UPDATE PLAN NOTE FOR | | | EGRESS WINDOWS MUST MEET THE REQUIREMENTS OF THE 2017 | | | FBC-B SECTION 1030 EMERGENCY ESCAPE AND RESCUE OPENINGS | | | IN R-2 OCCUPANCIES. | | | 1030.2 MINIMUM SIZE | | | 1030.2.1 MINIMUM DIMENSIONS. | | | 1030.3 MAXIMUM HEIGHT FROM FLOOR. | | | 1030.4 OPERATIONAL CONSTRAINTS. | | | | | | 2C) NOTE # 12 INDICATES THE EGRESS WINDOWS ARE TO BE | | | SHOWN ON THE PLANS, THE EGRESS WINDOWS ARE NOT SHOWN. | | | 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2D) THERE IS A DETAIL FOR CBS WALL INFILL WITH WOOD | | | FRAMING, 5/8 INCH PLYWOOD AND WIRE LATH AND STUCCO. THE | | | FLOOR PLAN DOES NOT INDICATE WHERE THIS DETAIL IS TO BE | | | USED. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2E) THERE IS A DETAIL FOR CBS WALL INFILL WITH WOOD | | | FRAMING, 5/8 INCH PLYWOOD AND WIRE LATH AND STUCCO. | | | THE DETAIL IS LACKING COMPLIANCE WITH 2017 FBC-B 2510.6 | | | WATER-RESISTIVE BARRIERS. WATER-RESISTIVE BARRIERS | | | SHALL BE INSTALLED AS REQUIRED IN SECTION 1404.2 AND, | | | WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE | | | A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A | | | PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF | | | WATER-RESISTIVE BARRIER COMPLYING WITH ASTM E2556, TYPE | | | I. THE INDIVIDUAL LAYERS SHALL BE INSTALLED | | | INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE | | | CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN | | | ACCORDANCE WITH SECTION 1405.4) INTENDED TO DRAIN TO | | | THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE | | | LAYERS. | | | | | | 2F) THE PLAN SHOWS SEPARATION WALLS BETWEEN EACH OF THE | | | DWELLING UNITS. STATED FROM THE PLAN: THE REPAIRS TO | | | THE PARTY WALL MUST BE MADE WITH 5/8 INCH DRYWALL AND 3 | | | ? INCH BATT INSULATION. | | | | | | THESE WALLS WERE TO BE BUILT AS FIRE PARTITIONS, PLEASE | | | PROVIDE THE WALL RATING AND ASSEMBLY FOR THIS WALL | | | SYSTEM. THE 2017 FBC-B SECTION 708.3 FIRE RESISTANCE | | | RATING. FIRE PARTITIONS SHALL HAVE A FIRE RESISTANCE | | | RATING OF NOT LESS THAN 1 HOUR. PLEASE PROVIDE THE UL | | | OR GYPSUM WALL ASSEMBLY. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-01-07 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-01-07 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-24 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-24 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2019-09-24 12:36:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. | | | 2. | | | 3. | | | 4. | | | 5. | | | 6. | | | 7. | | | 8. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-07-31 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-07-31 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2019-07-31 14:38:53 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. ARE PANELS BEING | | | REPLACED MAIN BREAKER OR MAIN LUG TYPE PANELS? PROVIDE | | | CLARIFICATIONS. NEC 215.5, 230, 250.50, 250.94, 408.30 | | | 2. | | | 3. | | | 4. | | | 5. | | | 6. | | | 7. | | | 8. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-16 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-16 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2019-05-16 14:01:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. ARE PANELS BEING | | | REPLACED MAIN BREAKER OR MAIN LUG TYPE PANELS? PROVIDE | | | CLARIFICATIONS. NEC 215.5, 230, 250.50, 250.94, 408.30 | | | 2. KITCHENS REQUIRE A MINUMUM OF TWO SMALL APPLIANCE | | | BRANCH CIRCUITS. PROVIDE CORRECTION. NEC 210.11(C)(1) | | | 3. PROVIDE ACCURATE LOAD CALCULATION. A MINUMUM OF TWO | | | SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED. NEC 220 | | | 4. PANEL SCHEDULE FOR UNITS STATE THAT THE ELECTRICAL | | | SERVICE IS 120/208 VOLT. LOAD CALCULATION STATES THE | | | SERVICE IS 120/240 VOLT. CORRECT DISCREPANCY. WPB FBC | | | 107.2.1 | | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12 | | | 6. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 7. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63 | | | 8. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-18 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-16 |
Time |
14:09 |
Sent To |
I |
|
| Notes |
| 2019-05-16 14:10:05 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET CVR - THERE NO INDICATIONS OF COMPLIANCE WITH | | | ANY FIRE CODE. | | | | | | THE PROPOSED PROJECTS SHALL MEET THE REQUIREMENTS OF | | | THE 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH | | | INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101. | | | | | | SPECIFICALLY, CH 31 EXISTING APARTMENT OCCUANCIES. | | | | | | PLEASE REVIEW NAD ENSURE COMPLIANCE AND PROVIDE AN | | | APPLICABLE NOTE OF CODE REFERENCE. | | | | | | | | | | | | | | | 2) SHEET A 1 - THE ARE REFERENCES TO EXISTING PARTY | | | WALLS BETWEEN EACH UNIT(S). | | | | | | DO THESE PARTY WALLS HAVE A FIRE RATING? DO THEY GO ALL | | | THE WAY TO THE UNDER SIDE OF THE ROOF SHEATHING? | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-07-23 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-07-23 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-05-14 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-05-14 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2021-01-07 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2021-01-07 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-09-24 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-24 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-20 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2019-09-23 14:59:06 | RESUB ROUTED TO PPETTY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-06 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-06 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2019-08-05 07:53:57 | TO CM DESK | | | | | 2019-07-17 15:25:02 | B06 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-16 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-24 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-08-06 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-08-06 |
Time |
14:14 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-06 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-06 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2019-05-06 12:18:24 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19041261 | | | 5/6/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE NOTE THERE ARE NO WPB BUILDING DEPARTMENT | | | RECORDS OF LEGALLY PERMITTED AC SYSTEMS BEING INSTALLED | | | AT THE APARTMENTS. REFER TO SECTION C503.2 FBC EC- FULL | | | COMPLIANCE WITH THE ENERGY CODE IS REQUIRED, WHICH | | | MEANS THAT THE FORM R402 MUST BE COMPLETELY FILLED OUT | | | AND THREE PAGES ARE MISSING. PLEASE REVIEW THE "SCOPE" | | | OF THE FORM LISTED IN THE TOP PRAGRAPH. IN ADDITION, | | | PLEASE NOTE THAT THE ENERGY FORM R402 AND THE AC | | | CALCULATIONS MUST BE SIGNED BY THE PERSON WHO PREPARED | | | THE FORM AND THE OWNER/AGENT- SECTION R103.1.1.2 FBC | | | EC. | | | | | | 2) SHEET M/P1: PROVIDE AC DUCT LAYOUT PLANS SHOWING | | | DUCT RUNS, DUCT SIZES, AND RETURNS. PLEASE NOTE THAT | | | ALTHOUGH THE PLAN IS INDICATING EXISTING DUCTWORK, | | | THERE ARE NO WPB BUILDING DEPARTMENT RECORDS OF ANY | | | PRIOR DUCT INSTALLATIONS- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-01 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-01 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-08-01 16:21:24 | PLUMBING COMMEMTS: APPROVED WITH PROVISO | | | 1. SUBMIT AS DEFERRED SUBMITTALS, SEE WPB FBC | | | 107.3.4.1, STORAGE TYPE WATER HEATER SPECS.SPECS SHALL | | | BE SUBMITTED, APPROVED AND IN PLACE PRIOR TO FINAL | | | PLUMBING INSPECTION. | | | 2. PER FBC PL 607.3, THERMAL EEXPANSION CONTROL SHALL | | | BE PROVIDED FOR STORAGE TYPE WATER HEATERS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-05-02 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-05-02 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |