Plan Review Details - Permit 19041232
| Plan Review Stops For Permit 19041232 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-22 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-22 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-15 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2019-05-15 09:24:18 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) FIRE DEPARTMENT EMERGENCY ACCESS IS REQUIRED AT THE | | | GATE ENTRANCE. | | | | | | PER NFPA 1 , CH 18 | | | | | | 18.2.2.2 ACCESS TO GATED SUBDIVISIONS OR DEVELOPMENTS. | | | THE AHJ | | | SHALL HAVE THE AUTHORITY TO REQUIRE FIRE DEPARTMENT | | | ACCESS BE PROVIDED | | | TO GATED SUBDIVISIONS OR DEVELOPMENTS THROUGH THE USE | | | OF AN APPROVED | | | DEVICE OR SYSTEM. | | | | | | A KNOX KEY SWITCH SYSTEM IS STRONGLY ENCOURGED TO BE | | | INSTALLED. | | | | | | PLEASE ENSURE COMPLIANCE AND COORDINATE WITH THE OFFICE | | | OF THE FIRE MARSHAL FOR LOCATION(S). | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-22 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-26 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-22 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
greihlic |
Date |
2019-05-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2019-05-08 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
|