Plan Review Details - Permit 19040921
Plan Review Stops For Permit 19040921
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-05-13 Cont ID  
Sent By thunt Date 2019-05-13 Time 16:17 Rev Time 0.00
Received By thunt Date 2019-05-13 Time 16:17 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-22 Cont ID  
Sent By thunt Date 2019-04-22 Time 16:45 Rev Time 0.00
Received By thunt Date 2019-04-22 Time 16:45 Sent To  
Notes
2019-04-22 16:46:02GAS 1ST REVIEW**DENIED**NOTE TO CONTRACTOR. NO GAS
 APPLIANCE SPECS WERE SUPPLIED ON THE MASTER PERMIT#
 18050348 AND ALL EQUIPMENT IS LISTED AS ELECTRIC. THE
 ONLY GAS LISTED IS A FUTURE GENERATOR. CALL AND SPOKE
 WITH JAMES PADGETT ( C&C GAS) ADVISED OF COMMENTS
  
 1) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 2) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE
 LOCATION OF THE TANKLESS WATER HEATER VENTING AND THE
 LOCATION AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS
 IN RELATION TO THE WATER HEATER. THE LOCATION OF THE
 WATER HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND
 DRAWN. WPB AMEND. TO FBC SEC. 107.2.1.
  
 3) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS
 APPLIANCES. WHERE COMBUSTION AIR IS PROVIDED BY THE
 BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR. 2017 FBC-FUEL
 GAS SEC.304.9.3 OR FBCR G2407.9.3.
  
 4) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION. 2014 FGC SEC.410.1, 2017 FBC-RES. SEC.
 G2421.1.
  
 5) PROVIDE SCOPE OF WORK DETAIL ON THE EXISTING HOME.
 WHAT GAS WORK IF ANY IS BEING COMPLETED. PLEASE
 CLARIFY. FBC 107.2.1
  
 6) PROVIDE A FLAT DRAWING OF THE GAS SYSTEM. FBC
 107.2.1
  
 7) VALUATIONS REQUIRED FOR THE GAS APPLIANCES AS THE
 APPROVED MASTER LIST ALL APPLIANCES AS ELECTRIC AND NOT
 GAS FBC WPB AMEND 109.3. A COMPLETED REVISION FOR ALL
 TRADES IS REQUIRED FOR MASTER PERMIT # 18050348.
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-13 Cont ID  
Sent By thunt Date 2019-05-13 Time 16:17 Rev Time 0.00
Received By thunt Date 2019-05-10 Time 13:00 Sent To  
Notes
2019-05-13 13:00:55RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-22 Cont ID  
Sent By thunt Date 2019-04-22 Time 16:46 Rev Time 0.00
Received By thunt Date 2019-04-18 Time 13:19 Sent To  
Notes
2019-04-19 13:19:39PLUMB <5K