Plan Review Details - Permit 19040872
Plan Review Stops For Permit 19040872
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-01 Cont ID  
Sent By pvalenti Date 2019-05-01 Time 15:31 Rev Time 0.00
Received By pvalenti Date 2019-05-01 Time 15:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pvalenti Date 2019-05-01 Time 13:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-05-01 Cont ID  
Sent By jleahy Date 2019-05-01 Time 15:40 Rev Time 0.00
Received By jleahy Date 2019-05-01 Time 15:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-01 Cont ID  
Sent By jleahy Date 2019-05-01 Time 15:44 Rev Time 0.00
Received By jleahy Date 2019-04-17 Time 11:37 Sent To  
Notes
2019-04-18 11:37:46ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-04-30 Cont ID  
Sent By thunt Date 2019-04-30 Time 12:53 Rev Time 0.00
Received By thunt Date 2019-04-30 Time 12:53 Sent To  
Notes
2019-04-30 12:54:17CONTRACTOR EMAILED MISSING TDH PAPERWORK. SINCE NO
 OTHER REVIEWS HAD BEEN PERFORMED TKL APPROVED PRINTED
 AND APPROVING PLAN. THUNT

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-24 Cont ID  
Sent By thunt Date 2019-04-24 Time 16:04 Rev Time 0.00
Received By thunt Date 2019-04-24 Time 16:04 Sent To  
Notes
2019-04-24 16:05:21PLUMBING 1ST REVIEW**DENIED**
  
 1)SUBMIT TOTAL DYNAMIC HEAD (TDH) CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE AND THE SIMPLIFIED TOTAL DYNAMIC HEAD
 CALCULATION IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS
 MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING
 SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER,
 FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT
 THE PUMP.
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2019-04-23 Cont ID  
Sent By mcruz Date 2019-04-23 Time 16:26 Rev Time 0.00
Received By mcruz Date 2019-04-23 Time 16:10 Sent To  
Notes
***NONE***