Plan Review Details - Permit 19040847
Plan Review Stops For Permit 19040847
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-04 Cont ID  
Sent By rmcdouga Date 2019-06-04 Time 14:21 Rev Time 0.00
Received By rmcdouga Date 2019-06-04 Time 13:14 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-05-02 Cont ID  
Sent By rmcdouga Date 2019-05-02 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2019-05-02 Time 09:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-04 Cont ID  
Sent By rmcdouga Date 2019-06-04 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2019-06-04 Time 13:36 Sent To  
Notes
2019-06-04 13:37:51CHANGED POOL HEATER FROM ELECTRIC HEAT PUMP TO NATURAL
 GAS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-02 Cont ID  
Sent By rmcdouga Date 2019-05-02 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2019-05-02 Time 10:12 Sent To I
Notes
2019-05-02 10:37:16PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY ELECTRICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS SPECIFY A 60 AMP POOL SUB-PANEL WITH A 2
 POLE 20 AMP BREAKER FOR A GAS POOL HEATER. THE
 SPECIFICATIONS FOR A 6.37 KW ELECTRIC HEAT PUMP WAS
 SUBMITTED. PLEASE COORDINATE THE PLANS WITH THE POOL
 HEATER SPECIFICATIONS. FBC 107.2.1
  
 2) SUBMIT TWO SETS OF ELECTRICAL LOAD CALCULATIONS FOR
 THE EXISTING HOUSE TO SHOW THAT THE EXISTING PANEL IS
 ADEQUATE. THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE IS REQUIRED ON THE CALCULATION DOCUMENTS.
 FBC E3401.4
  
 3) AN ELECTRICAL POOL SUB-PERMIT IS REQUIRED. FBC 105.1
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-06-04 Cont ID  
Sent By rmcdouga Date 2019-06-04 Time 13:38 Rev Time 0.00
Received By rmcdouga Date 2019-06-04 Time 13:38 Sent To  
Notes
2019-06-04 13:40:32A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT A SEPARATE
 PERMIT APPLICATION AND GAS RISER PLANS FOR THE GAS
 PERMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-04 Cont ID  
Sent By rmcdouga Date 2019-06-04 Time 14:22 Rev Time 0.00
Received By rmcdouga Date 2019-05-29 Time 15:15 Sent To  
Notes
2019-05-30 15:15:40RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-02 Cont ID  
Sent By rmcdouga Date 2019-05-02 Time 10:37 Rev Time 0.00
Received By rmcdouga Date 2019-04-16 Time 12:43 Sent To  
Notes
2019-04-17 12:43:36ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-06-04 Cont ID  
Sent By thunt Date 2019-06-04 Time 10:02 Rev Time 0.00
Received By thunt Date 2019-06-04 Time 10:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-04-24 Cont ID  
Sent By thunt Date 2019-04-24 Time 17:17 Rev Time 0.00
Received By thunt Date 2019-04-24 Time 17:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-05-31 Cont ID  
Sent By mcruz Date 2019-05-31 Time 11:42 Rev Time 0.00
Received By mcruz Date 2019-05-31 Time 11:39 Sent To P
Notes
2019-05-31 11:42:40POOL EQUIPMENT SHALL BE AT LEAST 1' FROM SIDE PROPERTY
 LINE.

Review Stop Z ZONING
Rev No 1 Status P Date 2019-04-23 Cont ID  
Sent By mcruz Date 2019-04-23 Time 15:32 Rev Time 0.00
Received By mcruz Date 2019-04-23 Time 15:29 Sent To  
Notes
2019-04-23 15:32:14POOL EQUIPMENT SHALL BE AT LEAST A FOOT OFF THE SIDE
 PROPERTY LINE.