| Plan Review Stops For Permit 19040803 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-05 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2019-08-05 16:09:20 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1. AN APPROVED ROOFING SUB-PERMIT IS REQUIRED ON-SITE | | | PRIOR TO ROOF WORK. | | | 2. APPROVED BALCONY AND HANDRAIL CONNECTION DETAILS ARE | | | REQUIRED ON-SITE PRIOR TO INSPECTION. | | | 3. A BLOWER DOOR TEST FOR AIR LEAKAGE, HAS TO BE | | | COMPLETED BY AN APPROVED THIRD PARTY COMPANY AND IS | | | REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF C.O. AS | | | PER FBC EC R 402.4.1.2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-20 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-17 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2019-05-20 14:52:30 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1ST BUILDING PLAN REVIEW DENIED: | | | | | | 1. FBC B 107.2.1 THE DETAILS FOR LINTEL #21 ON SHEETS | | | 4/7 & 5/7 ARE NOT CLEAR AS TO MEETING THE REQUIRED LOAD | | | CAPACITY. PLEASE ADJUST AND CLARIFY. | | | | | | 2. FBC B 109.3 THE VALUATION OF THIS APPLICATION | | | APPEARS TO BE VERY LOW. PLEASE ADJUST AND CLARIFY. | | | | | | 3. FBC B 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, DOOR, AND | | | OVERHEAD GARAGE DOOR SUBMITTALS. | | | | | | NOTES: | | | A. PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. | | | CALL (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT | | | ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF. | | | | | | B. A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF WORK. | | | | | | C. BALCONY AND STAIR HANDRAIL SUBMITTALS ARE REQUIRED | | | TO BE APPROVED BY THE DESIGNER OF RECORD. | | | | | | D. A BLOWER DOOR TEST, FOR AIR LEAKAGE, HAS TO BE | | | COMPLETED BY THIRD PARTY AND IS REQUIRED TO BE | | | SUBMITTED PRIOR TO ISSUANCE OF C.O. AS PER FBC EC | | | R402.4.1.2. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-22 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-22 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2019-10-22 11:28:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS:PASS WITH PROVISO, SEE | | | COMMENTS BELOW. | | | | | | 1. | | | 2. | | | 3. | | | 4. | | | 5. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30,225.32 | | | 6. | | | 7. | | | 8. | | | 9. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-25 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-25 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2019-09-25 08:52:40 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | 2. | | | 3. | | | 4. | | | 5. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30,225.32 | | | 6. | | | 7. | | | 8. | | | 9. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | | 107.1, 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-08-27 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-08-27 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2019-08-27 11:37:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | 2. PLEASE SHOW LOCATION OF NEW PANEL. | | | 3. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | 4.PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 5. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 6. | | | 7. | | | 8. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER IS THIS | | | GAS OR ELECTRIC? WPB FBC 107.2.1 | | | 9. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | | 107.1, 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-07-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-07-26 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-07-26 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2019-07-26 10:33:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 2. | | | 3. | | | 4. | | | 5. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 6. | | | 7. | | | 8. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER IS THIS | | | GAS OR ELECTRIC? WPB FBC 107.2.1 | | | 9. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | | 107.1, 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-13 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-13 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2019-05-13 15:38:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 2. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION. WPB FBC 107.2.1; NEC | | | 230.2; FBC RE E3601.2 | | | 3. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC | | | 215.5; WPB FBC 107.2.1 | | | 4. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 5. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. PROVIDE CORRECTION. NEC | | | 225.30 | | | 6. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 7. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENERS. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 8. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER IS THIS | | | GAS OR ELECTRIC? WPB FBC 107.2.1 | | | 9. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | | 107.1, 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-07-18 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-07-18 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-05-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-05-02 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-10-22 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-10-11 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2019-10-22 08:27:39 | ROUTED TO PPETTY'S DESK | | 2019-10-15 14:00:07 | RESUB ROUTED TO JESMITH'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-09-25 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-09-25 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-09-23 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2019-09-24 14:50:34 | RESUB ROUTED TO PPETTY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-08-27 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-08-14 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2019-08-15 14:18:45 | RESUB ROUTED TO PPETTY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-11 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-06-17 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-06 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-20 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-16 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-10-28 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-10-28 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-10-28 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2019-10-28 10:21:42 | IMPACT FEE REVIEW: | | | | | | APPROVED, THE CONTRACTOR PROVIDED THE COUNTY STAMPED | | | PLAN AND RECEIPT # MU-2019-033384-0000. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-05 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2019-08-05 14:40:38 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | IMPACT FEE REVIEW DENIED: | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233?5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-20 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-20 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2019-05-20 14:54:39 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-07-27 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-07-27 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-05-15 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-05-15 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2019-05-15 14:16:32 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, 6TH EDITION (2017) SEC. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-10-22 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-10-22 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-10-22 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2019-10-22 08:24:24 | PLUMBING COMMEMTS: APPROVED WITH PROVISO | | | 1. PER WPB FBC 107.2.1 AND AS ALLOWED BY WPB FBC | | | 107.3.4.1 DEFERRED SUBMITTALS, PROVIDE THE COMPLETE | | | MANUFACTURER'S INSTALLATION MANUAL AND SPECIFICATIONS | | | FOR THE TANKLESS WATER HEATER. HEATER'S EFFICIENCY MUST | | | SHOW AS MIN .92EF TO MATCH THE R405 ENERGY FORM. THE KW | | | AND AMPERAGE SHALL MATCH THE ELECTRICAL LOAD TABLE ON | | | PLAN PAGE 7 OF 7. THE HEATER MUST BE ABLE TO PRODUCE | | | HOT WATER 110F TO MULTIPLE FIXTURES AT THE SAME TIME. | | | THIS SUBMITTAL SHALL BE SUBMITTED, APPROVED AND IN | | | PLACE PRIOR TO FINAL INSPECTION. CONTRACTOR PROCEEDS AT | | | HIS OWN RISK. | | | 2. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL. IT IS NOTED THAT A CODE COMPLIANT SANITARY | | | RISER DIAGRAM HAS BEEN SUBMITTED. STRUCTURAL DESIGN AND | | | FIXTURE LOCATIONS MAY WELL REQUIRE ADDITIONAL VENTRS | | | AND PIPING CONFIGURATIONS. IT IS THE CONTRACTOR'S | | | RESPONSIBILITY TO PROVIDE A CODE COMPLIANT | | | INSTALLATION. | | | 3. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO | | | WASHING MACHINE, ICE LINE AND DISHWASHER. FBC RES | | | P2903.5 | | | 4. THE COMBINED DISCHARGE FROM A DISHWASHER AND A ONE- | | | OR TWO-COMPARTMENT SINK, WITH OR WITHOUT A FOOD-WASTE | | | DISPOSER, SHALL BE SERVED BY A TRAP OF NOT LESS THAN | | | 11/2 INCHES (38 MM) IN OUTSIDE DIAMETER. THE DISHWASHER | | | DISCHARGE PIPE OR TUBING SHALL RISE TO THE UNDERSIDE OF | | | THE COUNTER AND BE FASTENED OR OTHERWISE HELD IN THAT | | | POSITION BEFORE CONNECTING TO THE HEAD OF THE FOOD | | | WASTE DISPOSAL OR TO A TEE-WYE FITTING IN THE SINK | | | TAILPIECE. FBC RES P2717.2 | | | 5. SHUT OFF VALVES FOR THE UNDER COUNTER WASHING | | | MACHINE AND ICE MAKER SHALL BE ACCESSIBLE. FBC RES | | | P2903.9.4 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-08-01 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-08-01 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2019-08-01 10:53:44 | PLUMBING COMMEMTS: APPROVED WITH PROVISO | | | 1. PER WPB FBC 107.2.1 AND AS ALLOWED BY WPB FBC | | | 107.3.4.1 DEFERRED SUBMITTALS, PROVIDE THE COMPLETE | | | MANUFACTURER?S INSTALLATION MANUAL AND SPECIFICATIONS | | | FOR THE TANKLESS WATER HEATER. HEATER'S EFFICIENCY MUST | | | SHOW AS MIN .92EF TO MATCH THE R405 ENERGY FORM. THE KW | | | AND AMPERAGE SHALL MATCH THE ELECTRICAL LOAD TABLE ON | | | PLAN PAGE 7 OF 7. THE HEATER MUST BE ABLE TO PRODUCE | | | HOT WATER 110F TO MULTIPLE FIXTURES AT THE SAME TIME. | | | THIS SUBMITTAL SHALL BE SUBMITTED, APPROVED AND IN | | | PLACE PRIOR TO FINAL INSPECTION. CONTRACTOR PROCEEDS AT | | | HIS OWN RISK. | | | 2. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR?S | | | APPROVAL. IT IS NOTED THAT A CODE COMPLIANT SANITARY | | | RISER DIAGRAM HAS BEEN SUBMITTED. STRUCTURAL DESIGN AND | | | FIXTURE LOCATIONS MAY WELL REQUIRE ADDITIONAL VENTRS | | | AND PIPING CONFIGURATIONS. IT IS THE CONTRACTOR'S | | | RESPONSIBILITY TO PROVIDE A CODE COMPLIANT | | | INSTALLATION. | | | 3. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO | | | WASHING MACHINE, ICE LINE AND DISHWASHER. FBC RES | | | P2903.5 | | | 4. THE COMBINED DISCHARGE FROM A DISHWASHER AND A ONE- | | | OR TWO-COMPARTMENT SINK, WITH OR WITHOUT A FOOD-WASTE | | | DISPOSER, SHALL BE SERVED BY A TRAP OF NOT LESS THAN | | | 11/2 INCHES (38 MM) IN OUTSIDE DIAMETER. THE DISHWASHER | | | DISCHARGE PIPE OR TUBING SHALL RISE TO THE UNDERSIDE OF | | | THE COUNTER AND BE FASTENED OR OTHERWISE HELD IN THAT | | | POSITION BEFORE CONNECTING TO THE HEAD OF THE FOOD | | | WASTE DISPOSAL OR TO A TEE-WYE FITTING IN THE SINK | | | TAILPIECE. FBC RES P2717.2 | | | 5. SHUT OFF VALVES FOR THE UNDER COUNTER WASHING | | | MACHINE AND ICE MAKER SHALL BE ACCESSIBLE. FBC RES | | | P2903.9.4 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-02 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2019-05-02 15:49:53 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) PROVIDE THE COMPLETE INSTALLATION MANUAL FOR THE | | | TANKLESS WATER HEATER. HEATER'S EFFICIENCY MUST SHOW AS | | | MIN .92EF TO MATCH THE R405 ENERGY FORM. PROVIDE HEAT | | | RISE CHART AS ON SHT #7 THE KW RATING IS LISTED AS | | | 4.5KW. THE HEATER MUST BE ABLE TO PRODUCE HOT WATER | | | 110F TO MUILT FIXTURES AT THE SAME TIME. FBC 107.2.1 | | | | | | 2) MIN TRAP SIZE FOR A WASHING MACHINE IS 2". PLAN ON | | | SHT.#7 CALLS OUT 1 1/2". FBC P 709.1 | | | | | | 3) DISHWASHER SHALL DISCHARGE BY MEANS OF AIR GAP AND | | | NOT DIRECTLY CONNECT INTO THE STACK. FBC-P 802.1.6 | | | | | | 4) TANKLESS SHALL HAVE CLEAR ACCES TO ALLOW FOR | | | OBSERVATIONS, MAINTENANCE, SERVICING, AND REPLACING. | | | FBC-R P 2801.5 | | | | | | 5) PROVIDE SHOWER PAN DETAIL. SHOW PRE-PITCH, FINISHED | | | CURB HEIGHT AND SHOWER PAN MATERIAL BEING USED FBC | | | 107.2.1 | | | | | | 6) PROVIDE LOCATION ON PLAN WHERE THE SHUT OFF VALVES | | | FOR THE UNDER COUNTER WASHING MACHINE AND ICE MAKER ARE | | | LOCATED. VALVES SHALL HAVE READY ACCESSIBLE. FBC-R | | | P2903.9.4 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-05 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2019-08-05 14:35:53 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | PLEASE PROVIDE ROOFING SUB-PERMIT PRIOR TO ROOF | | | INSTALLATION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-20 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-20 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2019-05-20 14:57:11 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1ST REVIEW DENIED: | | | | | | A ROOFING SUB PERMIT IS REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-07-18 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-07-18 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-05-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-05-02 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|