Plan Review Details - Permit 19040782
Plan Review Stops For Permit 19040782
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-17 Cont ID  
Sent By cthroop Date 2019-05-17 Time 14:06 Rev Time 0.00
Received By cthroop Date 2019-05-17 Time 12:55 Sent To  
Notes
2019-05-17 14:09:48BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 1. SEE PLAN PAGE A4.02. STAIR DETAIL REFERENCES DETAILS
 D,E&F 4.03. PLAN PAGE 4.03 IS MISSING. REVIEW OF STAIRS
 IS NOT COMPLETE.
  
 2. SEE STAIR DETAIL ON PAGE A4.02, OPENING BETWEEN
 GUARD AND STAIR SHALL NOT EXCEED 4 INCHES PER R312.1.3.
  
 3. STATE GOVERNING CODES ON COVER PAGE.
  
 4. ROOFING PERMIT REQUIRED.
  
 5. PROVIDE DESIGN PRESSURES OF ALL WINDOW AND EXTERIOR
 DOOR OPENINGS. PLACE ON WINDOW AND DOOR SCHEDULE OR
 PLACE ON PLAN NEXT TO EACH OPENING.
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 6. REF. PLAN PAGE A4.00. EXTERIOR WALL INSULATION IS
 SHOWN AS R-19 FOR 2ND FLOOR WOOD FRAMED WALLS. THE
 ENERGY SUBMITTAL DOES NOT HAVE ENERGY DATA FOR WOOD
 FRAMED WALLS. PLEASE CLARIFY
  
 7. REF. PLAN PAGE A4.00. R VALUE MISSING FROM PLAN FOR
 CMU EXT. WALL INSULATION. ENERGY SUBMITTAL SHOWS R4.1.
 PLEASE CLARIFY.
  
 8. THERE IS A CONFLICT BETWEEN PLAN PAGE D1.01 -
 PARTITIONS AND BEARING WALLS TO REMAIN AND PLAN PAGE
 A1.02 (B) NEW EXTERIOR WALLS. PLEASE CLARIFY.
  
 9. THERE IS A CONFLICT BETWEEN PLAN PAGE D1.02 -
 PARTITIONS AND BEARING WALLS TO REMAIN AND PLAN PAGE
 A1.03 (A) NEW EXTERIOR WALLS. PLEASE CLARIFY.
  
 10. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND
 EXTERIOR DOORS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  
  
  
  
2019-04-25 15:04:11PLAN REVIEWER, PLEASE EVALUATE THE APPROPRIATENESS OF
 REVOKING 17061319. ALSO LOOK AT ALL RECORDS TO
 DETERMINE ESTABLISHED UNITS ON PROPERTY AND APPLICABLE
 CODES, EXISTING & FBC OR RESIDENTIAL?. SAK

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-04-19 Cont ID  
Sent By fgiaquin Date 2019-04-19 Time 17:16 Rev Time 0.00
Received By fgiaquin Date 2019-04-19 Time 16:27 Sent To  
Notes
2019-04-19 17:16:04ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION. PLEASE SEE NEC
 220.85. METHOD USED FOR LOAD CALC WAS FOR 3 OR MORE
 DWELLINGS. 220.84 CAN BE USED IF THE LOAD CALC FOR 3
 IDENTICAL UNITS UNDER 220.84 IS LESS THAN THE NORMAL
 CALCULATION IN PART III FOR 2 UNITS. FBC 107.2.1 NEC
 220
  
 2. SPECIFY "OTHER LOADS" IN LOAD CALC. NEC 220 FBC
 107.2.1
  
 3. NO HOUSE PANEL BUT HOUSE PANEL SHOWN IN LOAD CALC,
 PROVIDE CORRECTION. FBC 107.2.1
  
 4. OVER HANG OF COUNTERTOP IN APARTMENT B IS MORE THAN
 6''. RECEPTACLE LOCATION IN PENINSULAR IS NOT CODE
 COMPLIANT. PROVIDE CORRECTION. NEC 210.52C5 (EXCEPTION
 TO #5)
  
 5. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL OF INSTAHOT.
 FBC 107.2.1 NEC 90.7, 110.2, 110.3B
  
 6. PROVIDE ATLEAST ONE RECEPTACLE ON PENINSULAR ISLAND
 THAT IS CODE COMPLIANT AND NOT UNDER THE OVERHAND OF
 THE COUNTERTOP IN APARTMENT C. NEC 210.52C5 (EXCEPTION
 TO #5)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:43 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
2019-09-10 15:43:59GAS SHALL BE BY SEPERATE PERMIT. PROVIDE ISOMETRIC
 DRAWING. CT

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-18 Cont ID  
Sent By thunt Date 2019-04-18 Time 16:40 Rev Time 0.00
Received By thunt Date 2019-04-18 Time 16:40 Sent To  
Notes
2019-04-18 16:40:47GAS 1ST REVIEW**DENIED**
  
 THE PLAN YOU SUBMITTED CALLS OUT FOR GAS BUT NO GAS
 PLAN OR SUBMITTAL DOCUMENTS HAVE BEEN SUPPLY. A GAS
 PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL PACKAGE. A
 GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT THIS TIME. A
 SEPARATE GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO
 PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT
 REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB
 AMEND. TO FBC SEC.107.2.1.
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-08-26 Cont ID  
Sent By fmittner Date 2019-08-26 Time 08:01 Rev Time 0.00
Received By fmittner Date 2019-08-26 Time 08:01 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-05-02 Cont ID  
Sent By fmittner Date 2019-05-02 Time 14:36 Rev Time 0.00
Received By fmittner Date 2019-05-02 Time 14:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-08-12 Time 08:26 Sent To  
Notes
2019-08-13 08:26:29RESUB ROUTED TO HISTORIC INBOX PER SKENNEDY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-17 Cont ID  
Sent By cthroop Date 2019-05-17 Time 14:58 Rev Time 0.00
Received By cthroop Date 2019-04-16 Time 14:23 Sent To  
Notes
2019-04-17 14:23:52R33

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-15 Cont ID  
Sent By cmontell Date 2019-05-15 Time 13:22 Rev Time 0.00
Received By cmontell Date 2019-05-17 Time 13:43 Sent To  
Notes
2019-05-15 13:22:18MECHANICAL PLAN REVIER FAIL
  
 1 - MANUAL J AND PLANS DO NOT MATCH
  
 CHRIS MONTELLO
 805-6733

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-18 Cont ID  
Sent By thunt Date 2019-04-18 Time 16:51 Rev Time 0.00
Received By thunt Date 2019-04-18 Time 16:51 Sent To  
Notes
2019-04-18 16:51:09PLUMBING 1ST REVIEW**DENIED** PLANS HAVE BEEN REVIEW
 USING CURRENT 2017 6TH ED. FLORIDA BUILDING CODE. A GAS
 PLAN AND PERMIT APPLICATION IS REQUIRED.
  
  
 1) SHT P-2 IS CALL OUT FOR GAS TITAN N-120 11.8KW.
 THERE IS NO SUCH HEATER. PLEASE CLARIFY AND SUPPLY
 MANUFACUTURE INSTALLATION MANUAL. IF THIS IS GOING TO
 BE GAS PLEASE CALL THIS REVIEWER AND I WILL EMAIL YOU
 THE REQUIREMENT CHECK LIST FOR GAS. FBC 107.3.5
  
 2) PROVIDE A CORRECTED R405 FORM AS THE CURRENT ONE IS
 LISTED A 50 GALLON ELECTRIC TANK WATER HEATER AT E.F
 90. THE CURRENT MIN FEDERAL REQUIREMENT IS E.F .95 OR
 U.E.F .92 ALSO YOU HAVE TANKLESS HEATERS ON MUILT
 SHEETS. FBC 107.2.1
  
 3) IT APPEARS THE WASHING MACHINE IS DISCHARGING INTO
 THE BATHROOM GROUP WET VENT. PLEASE CORRECT AND SHOW
 CONECTION DOWNSTREAM OF BATHROOM GROUPS. FBC P 912.1
  
 4) PROVIDE A CLEAR DETAIL OF PLUMBING FLAT DRAWING
 SIMILAR TO THE E-SHEETS AND LIST FIXTURE TYPE ON
 PLUMBING ISOMETRIC. FBC 107.3.5
  
 5) SHOW RPZ BACKFLOW ON MAIN WATER SERVICE AND LIST ON
 PLAN SEPERATE PERMIT REQUIRED BY LICENSE PLUMBING ONLY.
 PER WPB CROSS CONNECTION MANUAL
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-09-10 Cont ID  
Sent By cthroop Date 2019-09-10 Time 15:42 Rev Time 0.00
Received By cthroop Date 2019-09-10 Time 13:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-05-17 Cont ID  
Sent By cthroop Date 2019-05-17 Time 14:01 Rev Time 0.00
Received By cthroop Date 2019-05-17 Time 13:14 Sent To  
Notes
2019-05-17 14:05:52BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM
 COMPONENTS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 2. PROVIDE DESIGN PRESSURES FOR ROOF ZONES 2 & 3.
 FBC CHPT 3.
  
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-08-26 Cont ID  
Sent By fmittner Date 2019-08-26 Time 08:01 Rev Time 0.00
Received By fmittner Date 2019-08-26 Time 08:01 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-05-02 Cont ID  
Sent By fmittner Date 2019-05-02 Time 14:36 Rev Time 0.00
Received By fmittner Date 2019-05-02 Time 14:36 Sent To  
Notes
***NONE***