Plan Review Details - Permit 19040725
Plan Review Stops For Permit 19040725
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-16 Cont ID  
Sent By shill Date 2019-05-16 Time 11:01 Rev Time 0.00
Received By shill Date 2019-05-16 Time 11:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-06 Cont ID  
Sent By jwitmer Date 2019-05-06 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2019-05-06 Time 08:36 Sent To  
Notes
2019-05-06 09:44:432017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19040725
 ADD: 1771 PALM BEACH LAKES # W303
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected] / KARI NEVILLE
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. MAY 06/2019
 ACTION: DENIED
  
 1) THE COVERSHEET 001-A000 UNDER THE HEADING (4)
 OCCUPANT LOAD & EGRESS
 TOTAL OCCUPANT LOAD: 42 PEOPLE
 1A) LIST NUMBER OF EXITS REQUIRED AS (2), WRONG TABLE
 LIST TABLE 1021.2(2) SHOULD READ UNDER THE:
 2017 FBC-B TABLE 1006.3.2(2). PLEASE UPDATE PLANS.
  
 1B) THE SECOND ISSUE WITHIN THIS HEADING (4) OCCUPANT
 LOAD & EGRESS IS STATEMENT ( C ) NUMBER OF EXITS
 PROVIDED. THE 2017 FBC-B TABLE 1006.3.2(2) LIST THE
 NUMBER OF OCCUPANTS AS 49 OCCUPANTS AND THE MAXIMUM
 COMMON PATH OF TRAVEL IS 75 FEET EVEN IF SPRINKLERED.
 THIS TENANT SPACE IS OVER 100 FEET IN DEPTH REQUIRING 2
 EXITS.
  
 1C) PLEASE SHOW COMPLIANCE WITH SECTION 1016.2 EGRESS
 THROUGH INTERVENING SPACES OF THE 2017 FBC-B.
 1016.2.5. EGRESS SHALL NOT PASS THROUGH KITCHENS,
 STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
 PURPOSES.
 EXCEPTION: 2.MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHERE ALL OF THE
 FOLLOWING ARE MET:
 2.1.THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA.
 2.2.NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM.
 2.3.THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE.
 2.4.THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 2) THE DEMOLITION PLAN 012_A100 SHOWS AN ELEMENT
 (CIRCLE) IN FRONT OF THE ACCESSIBLE RESTROOM BUT THERE
 IS NO NOTE IT HAS TO BE REMOVED. WHEN YOU LOOK AT THE
 SHEET 014_A101 NEW WORK PLAN, THIS SAME CIRCLE THAT IS
 JUST TO THE RIGHT OF THE RESTROOM DOOR (LABELED 6)
 THERE ARE 2 NOTES. (1) EXISTING WATER METER & (2)
 LANDLORD NOTE: ARCHITECT OF RECORD IS RESPONSIBLE FOR
 ALL CODE COMPLIANCE INCLUDING ACCESSIBILITY, VERIFY
 PROTRUDING OBJECT REQUIREMENT AND DOOR CLEARANCE TO THE
 RESTROOM MEETS CODE.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY
 CODE SECTION 404.2.4 MANEUVERING CLEARANCES.
 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL
 COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL
 EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE OR HINGE SIDE CLEARANCE. SEE TABLE
 404.2.4.1, FIGURE 404.2.4.1(A).
  
 3) SHEET 028_ A202 DETAIL (2) DOES NOT PROVIDE THE
 HEIGHT OF THE REAR TOILET GRAB BAR AND IN DETAIL (3)
 THE HEIGHT OF THE TOILET GRAB BAR FROM THE FLOOR TO THE
 CENTERLINE OF THE BAR IS DIMENSIONED AS 39 INCHES -41
 INCHES. PLEASE SHOW COMPLIANCE WITH THE 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-05-04 Cont ID  
Sent By jleahy Date 2019-05-04 Time 08:52 Rev Time 0.00
Received By jleahy Date 2019-05-04 Time 08:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-04-23 Cont ID  
Sent By scaldero Date 2019-04-23 Time 10:56 Rev Time 0.00
Received By scaldero Date 2019-04-23 Time 10:51 Sent To  
Notes
2019-04-23 10:56:28PERMIT # 19040725
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING
 (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE
 FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.
  
 2) ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A
 LOCK/UNLOCK INDICATOR.
  
 3) EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED
 WITH SIGNS OR STENCILING READING FIRE BARRIER-PROTECT
 ALL OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 4) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN
 STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE
 MAINTAINED AT ALL TIMES.
  
 5) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO
 THE FIRE ALARM AND SPRINKLER SYSTEM.
  
 6) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT
 SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED
 AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE
 MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM
 SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD
 INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY
 BE NEEDED.
  
  
 SUE ELLEN CALDERON
 ASST. FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-16 Cont ID  
Sent By shill Date 2019-05-16 Time 11:02 Rev Time 0.00
Received By shill Date 2019-05-10 Time 11:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-05-06 Time 10:00 Rev Time 0.00
Received By lmarchan Date 2019-04-16 Time 11:02 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-05-06 Cont ID  
Sent By jwitmer Date 2019-05-06 Time 08:49 Rev Time 0.00
Received By jwitmer Date 2019-05-06 Time 08:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-05-01 Cont ID  
Sent By ccole Date 2019-05-01 Time 16:13 Rev Time 0.00
Received By ccole Date 2019-05-01 Time 15:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-15 Cont ID  
Sent By thunt Date 2019-05-15 Time 16:48 Rev Time 0.00
Received By thunt Date 2019-05-15 Time 16:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-25 Cont ID  
Sent By thunt Date 2019-04-25 Time 14:20 Rev Time 0.00
Received By thunt Date 2019-04-25 Time 12:17 Sent To  
Notes
2019-04-25 14:29:32PLUMBING 1ST REVIEW**DENIED**
  
  
 1) YOU DESIGN LAY OUT SEEM TO NO LONGER HAVE AN
 ACCESSIBLE ROUTE TO THE TOILETROOM FOR THE PUBLIC.
 REDUCTION IN ACCESS IS PROHIBITED UNDER FBC-ACC
 202.3.1. PROVIDE AN ACCESSIBLE ROUTED AND SAFE ACCESS
 FOR THE PUBLIC TO USE THE TOILET ROOM AND DRINKING
 FOUNTAIN AS DESIGNED AND APPROVED ON PERMIT#13090901
 SHT A002.
  
 2) SHT A003 SHOWS GRAB BARS LOCATED AT 36" TO THE
 CENTER. ALL GRAB BARS SHALL BE 33"-36" TO THE TOP
 GRIPPING SURFACE. FBC-ACC 609.4
  
 3) SHT A003 SHOWS CABINET 36" TO THE BOTTOM. FBC-ACC
 606.3 LIST MAX 34" TO THE TOP OF COUNTER TOP OR RIM OF
 SINK WHICH EVER IS GREATER.
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-05-16 Cont ID  
Sent By shill Date 2019-05-16 Time 11:02 Rev Time 0.00
Received By shill Date 2019-05-16 Time 11:00 Sent To  
Notes
2019-05-15 16:23:18SHT. E300.5 STILL NOT DIGITALLY SIGNED. ALL OTHER OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By shill Date 2019-05-07 Time 06:25 Rev Time 0.00
Received By shill Date 2019-05-07 Time 06:15 Sent To  
Notes
2019-05-07 06:25:41SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ARCHITECTURAL, FME PAGES, ENERGY CALCS HAVE A
 DIGITAL SIGNATURE WHICH ARE IN COMPLIANCE, NEW PAGES
 SUBMITTED IN SUBSEQUENT REVIEW CYCLES REQUIRE
 VERIFICATION.
  
  
2019-04-25 14:19:55SHT E300.5 HAS NOT BEEN DIGITALLY SIGNED. ALL OTHER OK

Review Stop Z ZONING
Rev No 1 Status P Date 2019-05-03 Cont ID  
Sent By eschneid Date 2019-05-03 Time 11:50 Rev Time 0.25
Received By eschneid Date 2019-05-03 Time 10:11 Sent To  
Notes
2019-05-03 11:56:28SIGNS REQUIRE SEPARATE PERMIT WITH PLANS.
  
 THE VIDEO SCREEN MAY NOT SHOW ADVERTISING COPY AS THE
 CITY DOES NOT PERMIT ELECTRONIC MESSAGE SIGNS.
  
  