Plan Review Details - Permit 19040601
Plan Review Stops For Permit 19040601
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By shill Date 2019-06-03 Time 10:36 Rev Time 0.00
Received By shill Date 2019-06-03 Time 10:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-04-30 Cont ID  
Sent By jwitmer Date 2019-04-30 Time 09:43 Rev Time 0.00
Received By jwitmer Date 2019-04-30 Time 09:43 Sent To  
Notes
2019-04-30 09:43:462017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19040601
 ADD: 2465 MERCER AVENUE, UNIT 202
 CONT: CHANDLER
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. APRIL 30/ 2019
 ACTION: DENIED
  
 1) THE COVERSHEET G001 UNDER THE HEADING, GOVERNING
 MUNICIPALITY: CITY OF LAUDERDALE LAKES, PLEASE CORRECT
 TO CITY OF WEST PALM BEACH. 107.2.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 2) THE FLOOR PLAN, A-102 INDICATES A NEW BREAK ROOM
 WITH ONLY 2 FOOT 8 INCHES IN FRONT OF THE BREAK ROOM
 SINK. PLEASE REVIEW THE 2017 FBC-ACCESSIBILITY CODE
 SECTION 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
 EXCEPTIONS:
 1. A PARALLEL APPROACH COMPLYING WITH 305 SHALL BE
 PERMITTED TO A KITCHEN SINK, IN A SPACE WHERE A COOK
 TOP OR CONVENTIONAL RANGE IS NOT PROVIDED, AND TO WET
 BARS.
 PLEASE NOTE IF THE PARALLEL APPROACH METHOD IS USED THE
 SINK CANNOT BE IN THE CORNER. THE 48 INCH CLEAR FLOOR
 SPACE WOULD NEED TO BE CENTERED ON THE SINK.
  
 3) SHEET A-501 TYPICAL CABINET BRACING DETAIL DOES NOT
 PROVIDE THE HEIGHT OF THE BREAK ROOM CABINET NOR THE
 HEIGHT OF THE LIP OF THE SINK. PLEASE SHOW COMPLIANCE
 WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION
 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 4) SHEET A201 SHOWS A NEW ACCESSIBLE RESTROOM WITH ONE
 DIMENSION 7 FEET 8 INCHES, BUT THE PLAN DOES NOT GIVE
 THE DIMENSION OF THE BACK WALL, NOR DOES THE PLAN SHOW
 THE DIMENSION OF THE WATER CLOSET TO THE NEAREST SIDE
 WALL NOR THE LAV TO THE NEAREST SIDE WALL. SHOW
 COMPLIANCE WITH THE 2017 ACCESSIBILITY CODE SECTIONS:
 604.3 CLEARANCE. CLEARANCES AROUND WATER CLOSETS AND IN
 TOILET COMPARTMENTS SHALL COMPLY WITH 604.3.
  
 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE
 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM
 THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL.
  
 604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND THE
 WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER
 CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY
 NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE
 ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT
 OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER
 FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE
 REQUIRED WATER CLOSET CLEARANCE.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-30 Cont ID  
Sent By ppetty Date 2019-05-30 Time 13:04 Rev Time 0.00
Received By ppetty Date 2019-05-30 Time 13:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-03 Cont ID  
Sent By jpearson Date 2019-05-03 Time 10:44 Rev Time 0.00
Received By jpearson Date 2019-05-02 Time 09:23 Sent To I
Notes
2019-05-03 09:59:49CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
 (S)
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-05-20 Cont ID  
Sent By pleduc Date 2019-05-20 Time   Rev Time 0.00
Received By pleduc Date 2019-05-20 Time 10:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-04-19 Cont ID  
Sent By scaldero Date 2019-04-19 Time 11:06 Rev Time 0.00
Received By scaldero Date 2019-04-19 Time 11:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-03 Cont ID  
Sent By shill Date 2019-06-03 Time 10:36 Rev Time 0.00
Received By shill Date 2019-05-14 Time 13:56 Sent To  
Notes
2019-05-15 13:56:54B04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-05-03 Time   Rev Time 0.00
Received By lmarchan Date 2019-04-11 Time 14:18 Sent To  
Notes
2019-04-12 14:19:07B22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-04-30 Cont ID  
Sent By jwitmer Date 2019-04-30 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2019-04-30 Time 09:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-05-31 Cont ID  
Sent By ccole Date 2019-05-31 Time 11:35 Rev Time 0.00
Received By ccole Date 2019-05-31 Time 11:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-04-29 Cont ID  
Sent By ccole Date 2019-04-29 Time 13:02 Rev Time 0.00
Received By ccole Date 2019-04-29 Time 13:02 Sent To  
Notes
2019-04-29 13:12:151ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19040601
 4/29/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-101: IT APPEARS THAT AIR THAT THE CORRIDOR
 IS BEING USED TO RETURN AIR FROM THE OFFICES VIA
 JUMPERS TO THE AIR HANDLER WHICH IS PROHIBITED- SEE
 SECTION 601.2. ALL RETURN AIR MUST BE DUCTED TO THE AIR
 HANDLER.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-22 Cont ID  
Sent By gjohnson Date 2019-05-22 Time 12:09 Rev Time 0.00
Received By gjohnson Date 2019-05-22 Time 07:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-25 Cont ID  
Sent By gjohnson Date 2019-04-25 Time 07:10 Rev Time 0.00
Received By gjohnson Date 2019-04-22 Time 15:26 Sent To  
Notes
2019-04-25 08:37:321ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1.INDICATE ON THE PLAN THE BREAK ROOM SINK SHALL COMPLY
 WITH FBC ACC 606.2 606.2 CLEAR FLOOR SPACE. A CLEAR
 FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A
 FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING
 WITH 306 SHALL BE PROVIDED. EXCEPTIONS: 1.A PARALLEL
 APPROACH COMPLYING WITH 305 SHALL BE PERMITTED TO A
 KITCHEN SINK, IN A SPACE WHERE A COOK TOP OR
 CONVENTIONAL RANGE IS NOT PROVIDED, AND TO WET BARS.THE
 CLEAR FLOOR SPACE SHALL BE CENTERED ON THE SINK.
 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 2. SHT A-102 SHOW DIMENSIONS ON THE CLEAR FLOOR SPACE
 FOR THE TOILET AND LAVATORY PER FBC ACC 606.2, 604.3.1
  
 3. SHT. A-102 SHOW DIMENSION OF THE WIDTH OF THE
 BATHROOM TO VERIFY COMPLIANCE WITH FBC ACC 606.2,
 604.3.1
  
 4. TWO DRINKING FOUNTAINS ARE REQUIRED PER FBC ACC
 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
 FBC PL [BE] 410.3 PROVIDE HIGH AND LOW DRINKING
 FOUNTAINS.
 WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT FEWER THAN
 TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS FOR PEOPLE
 WHO USE A WHEELCHAIR AND ONE DRINKING FOUNTAIN SHALL
 COMPLY WITH THE REQUIREMENTS FOR STANDING PERSONS.
 EXCEPTIONS: 1.A SINGLE DRINKING FOUNTAIN WITH TWO
 SEPARATE SPOUTS THAT COMPLIES WITH THE REQUIREMENTS FOR
 PEOPLE WHO USE A WHEELCHAIR AND STANDING PERSONS SHALL
 BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE
 DRINKING FOUNTAINS.
  
 5. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5
  
 6.THE DEMO PLAN A-101 DOES NOT SHOW ANY EXITING
 BATHROOM NOTE ON THE PLUMBING PAGE INDICATE THAT THERE
 IS EXISTING PIPING PLEASE SHOW ON THE SANITARY AND
 WATER ISOMETRIC DRAWINGS EXISTING AND NEW PIPING. PER
 WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]