| Plan Review Stops For Permit 19040582 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-16 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-15 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-04-30 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2019-04-30 13:08:49 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19040582 | | | ADD: 1309 N FLAGLER DR. / GOOD SAMARITAN MEDICAL CENTER | | | CONT: WESTBROOKE | | | TEL: 561-395-4126 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. APRIL 30/ 2019 | | | ACTION: DENIED | | | | | | 1) THE PHYSICIST REPORT NUCLEAR MEDICINE 2 & 3, MED-LAB | | | DRAWINGS BY SIEMENS SHEETS A-101, S-101 & S-501, NONE | | | ARE SIGNED AND SEALED. FOR THESE SHEETS NOT TO REQUIRE | | | A DESIGN PROFESSIONAL THEY WILL NEED TO BE TREATED AS | | | SHOP DRAWINGS TO BE REVIEWED BY THE DESIGNER OF RECORD, | | | AND APPROVED. THE DESIGNER OF RECORD THEN WOULD APPLY | | | THEIR SHOP DRAWING STAMP OF APPROVAL ON THE PLANS. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC... | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-19 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-19 |
Time |
08:50 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-03 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-03 |
Time |
11:15 |
Sent To |
I |
|
| Notes |
| 2019-05-03 15:05:13 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN SHEETS TOTAL 26 AND THEREFORE REQUIRE A DIGITAL | | | SUBMISSION. PROVIDE CORRECTION. PAPER PLANS WILL NOT BE | | | ACCEPTED. WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-26 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-26 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-25 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-03 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-11 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-04-30 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-16 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-29 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-29 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2019-04-29 12:02:54 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19040582 | | | 4/29/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | ASHRAE 170-2008 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-1: IT APPEARS THAT THE EXHAUST SYSTEM THAT | | | WILL BE OPERATED BY STARTUP/STOP PUSH BUTTONS IS NOT IN | | | COMPLIANCE WITH SECTION 6.7.1 ASHRAE 170-2008 WHICH | | | INDICATES THAT AIR DISTRIBUTION DESIGN SHALL MAINTAIN | | | THE PRESSURE RELATIONSHIPS IN ALL MODES OF HVAC | | | OPERATION. BASED ON THAT SECTION, THE EXHAUST SYSTEM | | | WILL HAVE TO OPERATE CONTINOUSLY TO MAINTAIN THE | | | REQUIRED NEGATIVE PRESSURE IN THE ROOM AND THE REQUIRED | | | AIR CHANGES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
P |
Date |
2019-09-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-09-05 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-09-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-10 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-10 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-22 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-22 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2019-04-22 14:42:03 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | MED GAS COMMENTS: | | | | | | 1. PLEASE PLACE NOTE ON PLAN THE CONTRACTOR AND ANYONE | | | INSTALLING MED GAS PIPING SHALL BE MED GAS CERTIFIED. | | | INSTALLERS SHALL PROVIDED PROOF FOR PERMIT ISSUE AND ON | | | JOBSITE FOR INSPECTORS APPROVAL . PER FAC 61G4-15.031 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-05-02 |
Time |
16:01 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-05-02 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|