Plan Review Details - Permit 19040485
| Plan Review Stops For Permit 19040485 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-22 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-22 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-04-10 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-10 |
Time |
15:11 |
Sent To |
HIST |
|
| Notes |
| 2019-04-10 15:17:52 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PLAN SHOWING LOCATION OF WINDOWS WITH | | | DIMENSIONS OF ROUGH OPENINGS. IF NO CHANGES ARE TO BE | | | MADE TO THE ROUGH OPENINGS, PROVIDE STATEMENT THAT | | | WINDOWS WILL BE LIKE FOR LIKE. IF OPENINGS ARE ALTERED, | | | PROVIDE FRAMING PLAN PER FBCR CHAPTER 6. | | | | | | 2. DESIGN WIND LOADS FOR EACH OPENING SHALL BE BASED ON | | | FBCR CHAPTER 3. | | | | | | 3. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE | | | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, | | | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF | | | WPB CHAPTER 109.3 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-21 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-05-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-05-21 |
Time |
16:28 |
Sent To |
B |
|
| Notes |
| 2019-05-21 16:30:24 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | | | | 1. ALL WINDOWS SHALL HAVE CLEAR GLASS OR LOW-E GLASS. | | | 2. ALL WINDOWS SHALL HAVE A 6/6 LITE PATTERN WITH | | | EXTERNAL OGEE DIMENSIONAL MUNTINS. AN EXCEPTION SHALL | | | EXIST THAT WILL REQUIRE THE TWO FIXED WINDOWS | | | IDENTIFIED IN THE PERMIT AND THE SECOND FLOOR CENTER | | | WINDOW WITH A 2/2 LITE PATTERN. THESE WINDOWS SHALL | | | MATCH THE EXISTING LITE PATTERN WITH EXTERNAL OGEE | | | DIMENSIONAL MUNTINS. | | | 3. ALL WINDOWS SHALL BE SIZED TO FIT THE WINDOW FRAME | | | OPENING AND THE LOCATION WITHIN THE WINDOW OPENING. | | | | | | STAFF RECOMMENDS STORING ON SITE, STORING OFF-SITE, | | | RECYCLING, OR DONATING EXISTING WOOD WINDOWS. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected] | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-04-11 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-04-11 |
Time |
10:06 |
Sent To |
PC |
|
| Notes |
| 2019-04-11 10:06:23 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. ALL WINDOWS MUST HAVE CLEAR GLASS OR LOW-E GLASS. | | | TINTED GLASS IS NOT ALLOWED. | | | 2. PROVIDE A PLAN SHOWING WINDOW FRAME SIZES, PROPOSED | | | WINDOW SIZE, WINDOW LOCATIONS, EXISTING WINDOW | | | CONFIGURATION, AND PROPOSED WINDOW CONFIGURATION. | | | 3. ALL WINDOWS MUST HAVE A 6/6 LITE PATTERN WITH | | | EXTERNAL OGEE DIMENSIONAL MUNTINS. AN EXCEPTION TO THE | | | 6/6 LITE PATTERN SHALL EXIST FOR THE SMALLER WINDOW | | | LOCATED ON THE PROPERTY. FOR EXAMPLE, THE FAR NORTHERN | | | FIRST FLOOR WINDOW ON THE STREET ELEVATION AND THE | | | SECOND FLOOR CENTER WINDOW. WINDOW REPLACEMENTS SHALL | | | THEN MATCH THE EXISTING CONFIGURATION. | | | 4. ALL WINDOWS MUST BE SINGLE-HUNG OR DOUBLE-HUNG. AN | | | ALUMINUM FIXED WINDOW WILL NOT BE PERMITTED. PLEASE | | | PROVIDE PROOF IF AN EXISTING FIXED WINDOW IS ON THE | | | PROPERTY. | | | 5. THE PLACEMENT OF THE PROPOSED REPLACEMENT WINDOWS | | | AND REPLACEMENT MULLION MUST MATCH THE EXISTING | | | CONFIGURATION AND PLACEMENT OF THE WINDOWS AND MULLION | | | AS CLOSELY AS POSSIBLE. | | | | | | STAFF RECOMMENDS RECYCLING OR STORING EXISTING WOOD | | | WINDOWS ON SITE. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-22 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-22 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-20 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-05-21 13:30:47 | RESUB ROUTED TO HISTORIC INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-04-11 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-04-10 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy