Plan Review Details - Permit 19040476
| Plan Review Stops For Permit 19040476 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-03 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-03 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-01 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-01 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-07-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-16 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-16 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-07-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-07-02 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-07-02 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2019-07-02 14:56:47 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-1 RECEPTACLE NEEDS TO BE INSTALLED AT FRONT OF | | | BUILDING | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE | | | INSTALLED OUTDOORS AT THE | | | FRONT AND BACK OF EACH DWELLING UNIT HAVING DIRECT | | | ACCESS TO GRADE LEVEL. BALCONIES, DECKS, AND PORCHES | | | THAT ARE ACCESSIBLE FROM INSIDE OF THE DWELLING UNIT | | | SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE | | | BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE | | | LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE | | | THE BALCONY, DECK, | | | OR PORCH SURFACE. | | | | | | KITCHEN COUNTER LOOKS TO BE MISSING OUTLETS FOR SPACING | | | E3901.4 COUNTERTOP RECEPTACLES. | | | IN KITCHENS PANTRIES, BREAKFAST ROOMS, DINING ROOMS AND | | | SIMILAR AREAS OF DWELLING UNITS, RECEPTACLE OUTLETS FOR | | | COUNTERTOP SPACES SHALL BE INSTALLED IN ACCORDANCE WITH | | | SECTIONS E3901.4.1 THROUGH E3901.4.5 | | | | | | OUTLETS INSTALLED SHALL MEET E3902 OF FBC FOR GFCI AND | | | AFCI PROTECTION. | | | | | | R315.1CARBON MONOXIDE PROTECTION. | | | EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING | | | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS | | | ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR | | | APPLIANCE, A FIREPLACE, AN | | | ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR ELEMENT | | | THAT EMITS CARBON MONOXIDE AS BYPRODUCT OF COMBUSTION | | | SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM | | | INSTALLED WITHIN | | | 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-25 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-25 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2019-04-25 15:49:23 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN, | | | DETAILING ALL WORK PROPOSED. THERE WERE TWO SHEETS | | | SUBMITTED NAMED A-1, WITH DIFFERENT INFORMATION ON | | | EACH. THE ONE THAT IS SEPARATE FROM THE OTHERS, AND WAS | | | NOT SIGNED, APPEARS TO BE AN ATTEMPT AT AN ELECTRICAL | | | PLAN. PROVIDE CORRECTIOIN. WPB FBC 107.2.1, 107.3.5; FS | | | 471, 481 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-07-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-03 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-18 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-05-03 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-04-10 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-05-03 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-05-03 |
Time |
08:51 |
Sent To |
I |
|
| Notes |
| 2019-05-03 09:10:14 | NOTE ON PLAN PAGE A-1 MECHANICAL WORK UNDER SEPARATE | | | PLAN AND PERMIT. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-01 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-01 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2019-05-01 18:05:02 | NOT A SUBSTANTIAL IMPROVEMENT | | | CUMULATIVE 5 YEAR $45,000 < 50% $119,055 PAPA | | | IMPROVEMENT VALUE | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-24 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-24 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-18 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-18 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-04-18 13:16:39 | PROVISO: PAN FOR WATER HEATER WITH DRAIN LINE GOING TO | | | THE OUTSIDE SHALL BE REQUIRED AS CURRENT GARAGE BEING | | | TURNED INTO LIVING SPACE NOW DAMAGE WILL BE CAUSED IT | | | WATER HEATER SHALL LEAK. |
|
|
|