| Plan Review Stops For Permit 19040317 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-07-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-07-22 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-07-22 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-16 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-04-29 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-07-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-24 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-24 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-24 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-24 |
Time |
08:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-16 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-16 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-29 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-29 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-10 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-10 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-09 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-09 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-30 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-03 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-02 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-04-05 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2019-04-09 09:08:29 | B03 | | 2019-04-08 15:58:35 | B01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-07-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-30 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-30 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2019-07-30 13:29:28 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | | | | | | | | | | THE PLANS NOW SHOW HARD CEILINGS WITH INSULATION AS PER | | | PRIOR REVIEW NOTES. | | | | | | APPROVED WITH PROVISO: | | | | | | THE AIR HANDLER LOCATED ABOVE THE CEILING IS REQUIRED | | | TO HAVE A CEILING ACCESS OPENING LARGE ENOUGH TO REMOVE | | | THE LARGEST APPLIANCE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-06-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-06-13 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-06-13 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2019-06-13 11:21:27 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #19040317 | | | 5/13/19 | | | | | | APPLICABLE CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) INSULATION INSTALLED ON A SUSPENDED CEILING WITH | | | REMOVABLE CEILING TILES SHALL NOT BE CONSIDERED PART OF | | | THE MINIMUM THERMAL RESISTANCE OF THE ROOF INSULATION- | | | SECTION C402.2.2 FBC EC. THE SUBMITTED INPUT DATA | | | REPORT ATTACHED TO THE ENERGYGAUGE COMPLIANCE REPORT | | | SHOWS R-11 IN THE MTL BLDG ROOF WHICH DOES NOT | | | REPRESENT THE ACTUAL FIELD CONDITIONS. IN ADDITION, | | | PLEASE REVIEW THE 2015 IECC COMMENTARY REGARDING | | | INSULATION ON THE UPPERSIDE OF THE CEILING TILES: "THE | | | CODE PROHIBITS CONDIDERING TH INSULATION ON THE UPPER | | | SIDE OF REMOVABLE CEILING TILES AS A PORTION OF THE | | | REQUIRED INSULATION. THEREFORE, ON SUSPENDED CEILING | | | SYSTEMS WITH REMOVABLE TILES, ANY INSULATION INSTALLED | | | AT THIS LOCATION IS NOT CONSIDERED AS CONTRIBUTING TO | | | THE MINIMUM REQUIRED BUILDING THERMAL ENVELOPE | | | PROVISIONS." | | | IN ORDER TO ADDRESS THIS SITUATION, IT APPEARS | | | INSULATION WOULD BE CREDITIED IF IS INSTALLED ABOVE A | | | HARD CEILING, OR IF THE WALLS AND THERMAL BARRIERS | | | EXTENDED UP TO THE ROOF DECK AND THE ROOF WAS INSULATED | | | TO MINIMUM R-10. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-13 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-10 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2019-05-13 08:56:37 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19040317 | | | 5/13/19 | | | | | | APPLICABLE CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO SECTION C407.2.1 FBC EC : "THE ROOF OR | | | CEILING THAT FUNCTIONS AS THE BUILDING'S THERMAL | | | ENVELOPE SHALL BE INSULATED TO AN R-VALUE OF AT LEAST | | | R-10. MULTIPLE-FAMILY RESIDENTIAL ROOFS/CEILINGS SHALL | | | BE INSULATED TO AN R-VALUE OF AT LEAST R-19, SPACE | | | PERMITTING. WHERE CAVITIES BENEATH A ROOF DECK ARE | | | VENTILATED, THE CEILING SHALL BE CONSIDERED THE | | | ENVELOPE COMPONENT UTILIZED IN THE COMMISSION APPROVED | | | COMPLIANCE SOFTWARE TOOLS." THE REVISED PLANS AND | | | SUBMITTED ENERGYGAUGE REPORT ARE NOT IN COMPLIANCE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-24 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-24 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2019-04-24 17:24:08 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19040317 | | | 4/24/19 | | | | | | APPLICABLE CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NO MECHANICAL PLANS WERE SUBMITTED. PLEASE PROVIDE | | | MECHANICAL PLANS AND SPECIFICATIONS INCLUDING: | | | A) AC PLAN SHOWING THE LOCATIONS OF THE AIR HANDLER AND | | | CONDENSER, AND DUCT LAYOUT- SECTION 107.2.1 WPB. | | | B) AC EQUIPMENT SCHEDULE- SECTION 107.2.1 WPB | | | C) AC COOLING AND HEATING SYSTEM SIZING CALCULATIONS- | | | SECTION C403.2.1 FBC EC | | | D) ENERGY CALCULATIONS FOR THE NEW CONDITIONED OFFICE | | | SPACE- SECTION C503.2 FBC EC. | | | E) VENTILATION CALULATIONS INDICATING THE REQUIRED AND | | | PROVIDED OUTDOOR AIR CFMS- TABLE 403.3.1.1 FBC M. | | | F) CONDENSATE DISPOSAL PLAN- SECTION 307.2.1 FBC M. | | | G) CONDENSER INSTALLATION DETAILS- SECTION 301.15 FBC | | | M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-19 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-18 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2019-07-19 10:18:43 | PLUMBING PROVISO: | | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR?S | | | APPROVAL. | | | 2. ALL PLUMBING WORK SHALL COMPLY WITH FBC PLUMBING 6TH | | | EDITION 2017 | | | 4. THE CENTER OF THE TOILET SHALL BE 16" MIN 18 MAX OFF | | | THE SIDE WALL. PER FBC ACC 604.2 | | | 5. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3.PER FBC PL 416.5 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-18 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-18 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2019-06-18 08:26:51 | PLUMBING PROVISO: | | | | | | 1) PROVIDE TANKLESS WATER HEATER INSTALLATION MANUAL @ | | | TIME OF INSPECTION. TANKLESS SHALL BE SIZED SO THAT IT | | | CAN PRODUCE HOT/TEMPERED WATER TO ALL REQUIRED FIXTURES | | | AT FULL DEMAND. | | | | | | 2) A THERMOSTAT CONTROL FOR A WATER HEATER SHALL NOT | | | SERVE AS THE TEMPERING LIMITING DEVICE. FBC P607.1.1 | | | | | | 3) TEMPERED WATER SHALL BE SUPPLIED BY MEANS OF AN | | | APPROVED ASSE 1070 DEVICE LIMITED TO 110F TO ALL HAND | | | WASH SINKS. FBC P607.1.2 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-06 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-06 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-19 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-19 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2019-04-19 10:43:44 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WATER FOUNTAIN AND UTILITY SINK SHALL CONNECT TO | | | BUILDING DRAIN DOWNSREAM OF THE BATHROOM GROUP. PER FBC | | | PL 912.1 | | | | | | 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|