| Plan Review Stops For Permit 19040235 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-13 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-13 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2019-05-13 10:54:43 | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW APPROVED AS PER SUBMITTALS; THE | | | FLOORING SUBMITTALS ARE FOR TILE WITH PROFLEX 90. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-30 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-30 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2019-04-30 17:15:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? IF THE UNDERLAYMENT PRODUCT PROPOSED IS NOT | | | ONE FOR WHICH WE HAVE TEST REPORTS ON FILE, THE | | | FOLLOWING REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-13 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-13 |
Time |
15:43 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-18 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-18 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-04-18 14:34:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER | | | SPACE STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED | | | SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 | | | INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET | | | IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS | | | CODE IN SOME AREAS. SHOW RECEPTACLE OUTLETS AS NEW OR | | | EXISTING AS APPLIES. PROVIDE CORRECTION. NEC | | | 210.52(C)(1) | | | 2. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D) | | | 3. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET ON THE | | | KITCHEN PENINSULA. NEC 210.8, 210.52(C)(3) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-10 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-09 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-09 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-05-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-06 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-30 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-04 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-09 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-09 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-18 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-18 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2019-04-18 10:19:27 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19040235 | | | 4/18/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS | | | WITH CORRESPONDING DRAWINGS AND DETAILS- SECTION | | | 107.2.1 WPB. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW | | | RANGE AND EXHAUST HOOD, AND ANY OTHER NEW COOKING | | | APPLIANCES- SECTIONS 505.1 AND 917.1 FBC M. PLEASE SEE | | | SECTION 505.2 PRINTED BELOW AND SHOW COMPLIANCE. | | | | | | 505.2 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CFM (0.19 M3/S) SHALL BE PROVIDED WITH MAKEUP AIR | | | AT A RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. | | | SUCH MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH A MEANS | | | OF CLOSURE AND SHALL BE AUTOMATICALLY CONTROLLED TO | | | START AND OPERATE SIMULTANEOUSLY WITH THE EXHAUST | | | SYSTEM. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-09 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-09 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-04-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-12 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-12 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|