Plan Review Details - Permit 19040018
| Plan Review Stops For Permit 19040018 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-09 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-09 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2019-07-09 09:33:06 | MASTER PERMIT CLOSED OUT, ISSUES RESOLVED ON MASTER | | | PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-08 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-08 |
Time |
09:06 |
Sent To |
P |
|
| Notes |
| 2019-04-08 09:06:02 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. REVISION SHOWS SEVERAL ITEMS BEING ADDED, BUT THE | | | STATED VALUE FOR REVISION IS $0.00 . PROVIDE COPY OF | | | SIGNED CONTRACT WITH SCOPE AND VALUE OF WORK, TO | | | INCLUDE ALL MATERIALS AND LABOR. THIS IS FOR TOTAL | | | PROJECT, NOT JUST ELECTRICAL. WPB FBC 109.3 | | | 2. A SEPARATE PERMIT IS REQUIRED FOR LOW VOLTAGE | | | SYSTEMS. TO DATE, THIS PERMIT HAS NOT BEEN OBTAINED. | | | PROVIDE EITHER A NOTE ON PLAN THAT REQUIRES SEPARATE | | | PERMIT, OR OBTAIN LOW VOLTAGE PERMIT AND PROVIDE THAT | | | PERMIT NUMBER. WPB FBC 105.1; 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-09 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-01 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2019-04-03 09:19:26 | REVISION ROUTED TO JPEARSON |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-09 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-09 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2019-07-09 09:54:12 | PLUMBING HAS PASSED FINAL INSPECTION. | | 2019-04-09 15:51:36 | 1ST REVIEW: 19031092 | | | | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. 3.1P THE SANITARY FOR THE SINKS IN TREATMENT | | | ROOM 11+12 IS STILL SHOWING BACK TO BACK SINKS IT | | | SHOULD MATCH FLOOR PLAN WITH TO SINGLE SINK PLEASE | | | CLARIFY. PER WPB AMEND TO FBC107.2.1 | | | 2. SHT. 3.2P THE SANITARY ISOMETRIC IS SHOWING BACK TO | | | BACK SINKS FOR ROOM 11+12 IT SHOULD BE SHOWING SINGLE | | | SINKS. TO MATCH FLOOR PLAN PLEASE CLARIFY. PER WPB | | | AMEND TO FBC107.2.1 | | | 3. SHT. 3.2P THE WATER ISOMETRIC IS MISSING PIPING FOR | | | A SINK FOR ROOM 12 IT SHOULD BE SHOWING 2 SINGLE SINKS. | | | TO MATCH FLOOR PLAN PLEASE CLARIFY. PER WPB AMEND TO | | | FBC107.2.1 | | | 4. THE LAVATORY,S IN THE BATHROOMS ARE REQUIRED TI HAVE | | | TEMPERED WATER WITH A TEMPERATURE BELOW 110 DEQ. THE | | | WASHING MACHINE AND THE OTHER SINKS ARE REQUIRED TO | | | HAVE HOT WATER ABOVE 110 DEQ. THE PLAN SHOWS A SINGLE | | | TEMPERING VALVE HOW WILL THIS BE ACHIEVED WITH A SINGLE | | | TEMPERATURE LIMITING DEVICE AND A SINGLE LINE SYSTEM | | | PLEASE CLARIFY. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
|