| Plan Review Stops For Permit 19031377 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-24 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-20 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-30 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-24 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2019-05-30 08:11:01 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 1. PROVIDE SITE DRAINAGE PLAN. 2ND REQUEST. | | | FBC R401.3 | | | | | | DRAINAGE PLAN C-1 MISSING EXISTING GRADES AND PROPOSED | | | GRADES. | | | | | | 2. PROVIDE FINISH FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | FINISH FLOOR ELEVATION ON PLAN PAGE C-1 (DRAINAGE PLAN) | | | SHOWS 13.88 FEET. | | | FINISH FLOOR ELEVATION ON PROPOSED SURVEY SHOWS 13.00 | | | FEET. | | | PLEASE CLARIFY. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-15 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-10 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2019-04-15 14:59:44 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | 2. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | 3. ROOFING PERMIT REQUIRED. FBC 105 PERMITS | | | | | | 4. PROVIDE WINDOW AND DOOR SCHEDULE. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. PROVIDE DESIGN PRESSURES FOR WINDOW AND DOOR | | | OPENINGS. | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | 6. SHOW LOCATION AND TYPE OF WATER HEATER ON PLAN. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-30 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-24 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-16 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-10 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2019-04-16 07:14:30 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THE FOLLOWING REVIEW COMMENTS APPLY TO THE MAIN HOUSE | | | AND CABANA. A NOTE HAS BEEN PROVIDED WHERE THE COMMENT | | | APPLIES ONLY TO ONE STRUCTURE. | | | | | | 1. PROVIDE AIC CALCULATIONS | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3404.2 & FBC RE E3606.3 | | | | | | 2. PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE | | | MARKED WITH THE AIC RATING. | | | PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE MARKED | | | WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT | | | AVAILABLE PER NEC 110.24 & FBC RE E3606.4 | | | PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. NEC | | | 110.3, 110.9; FBC RE E3606.4 | | | | | | 3. PROVIDE ACCURATE LOAD CALCULATIONS FOR EACH PANEL | | | SEPERATELY, INCLUDING ALL LOADS. NEC 220; FBC RE | | | E3602.2 | | | 3A. MAIN HOUSE CALCULATIONS - | | | 3B. CABANA CALCULATIONS - | | | 3C. COMBINATION CALCULATIONS - PROVIDED | | | | | | 4. HOUSE ONLY COMMENT - PLAN INDICATES A FPL METER | | | COMBO AND A 150 AMP PANEL LOCATED IN FOYER. RISER | | | DIAGRAHM INDICATES A SEPERATE METER CAN WITH A 200 AMP | | | PANEL WITH A MCB. IF METER COMBO IS UTILIZED THEN THE | | | DETAIL SHOWING A 2 INCH CONDUIT WITH 3-#3/0 CONDUCTORS | | | WITH A #6 GRND. ( THIS WOULD BE AN INTERNAL CONNECTION) | | | AND THE 150 AMP PANEL IN THE FOYER NEEDS TO BE REMOVED. | | | PLEASE CLARIFY. | | | | | | 5. INDICATE ON PLAN THE TYPE OF GROUND TO BE USED AT | | | EACH STRUCTURE. (I.E. GROUND RODS, CONCRETE ENCASED | | | STEEL RE-INFORCING, WATER PIPES, ETC.) | | | A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | | | | 6. IDENTIFY INTERSYSTEM BONDING TERMINAL AT EACH | | | SERVICE. | | | PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | | | | 7. GROUNDING ELECTRODE SHALL BE SIZED PER TABLE | | | E3603.4. THIS IS IN REFERENCE TO THE DETAIL SHOWING | | | SEPERATE METER AND SERVICE. #6 GROUND WIRE IS | | | UNDERSIZED FOR 3-#3/0 UNGROUNDED CONDUCTORS. | | | | | | 8. CABANA ONLY COMMENT - PROVIDE SERVICE OUTLET FOR | | | MINI-SPLIT OUTDOOR C/U UNIT. | | | E3901.12 HVAC OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE | | | LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM) | | | OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED | | | TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING | | | MEANS. (210.63) | | | | | | 9. HOUSE ONLY COMMENT - LAUNDRY ROOM OUTLET SHALL BE | | | GFCI PROTECTED. | | | E3902.9 LAUNDRY AREAS. | | | 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES | | | INSTALLED IN LAUNDRY AREAS SHALL HAVE GROUND-FAULT | | | CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. | | | [210.8(A)(9)] E3902.16. | | | | | | 10. PROVIDE ARC FAULT CIRCUT PROTECTION PER E3902.16 | | | FBCRE3902.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, | | | 15- AND 20-AMPERE OUTLETS INSTALLED IN FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED | | | BY A COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER | | | INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. | | | | | | 11. PROVIDE THE FOLLOWING STATEMENT ON PLAN FOR | | | PERMENTELY INSTALLED LUMINAIRES: | | | PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | | | | 12. EXHAUST FAN SYMBOL MISSING FROM LEGEND. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 13. STATE CFM FOR EACH EXHAUST FANS. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-28 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-28 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2019-05-28 09:45:55 | GAS PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | GAS PLAN REVIEW | | | | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | WATER HEATER INSTALLATION. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-10 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-10 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-06-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-24 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-10 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-31 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-24 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-19 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-29 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2019-04-18 06:43:50 | 4/15 CONVERTED TO DIGITAL IN ORDER TO FACILITATE FASTER | | | REVIEWS | | | | | | | | | | | | | | 2019-04-01 13:30:51 | R27 | | | **TRAVELLING TOGETHER - 19031377 & 19031379** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-06-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-06-29 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-06-25 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2019-06-29 10:13:21 | 6/29/19 IMPACT FEES PAID & PROJECTDOX STAMPED - MU | | | 2019-020101 | | 2019-06-25 13:51:54 | 6/25/19 SENT EMAIL TO IMPACT OFFICE. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-15 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-10 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2019-04-15 15:00:54 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-28 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-24 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-15 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-10 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2019-04-15 15:20:12 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SPECIFY EQUIPMENT TO BE INSTALLED. LIST EQUIPMENT ON | | | ENERGY SUBMITTAL AND PLANS. | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. PROVIDE EQUIPMENT SIZING. | | | M1401.3 EQUIPMENT AND APPLIANCE SIZING. | | | HEATING AND COOLING EQUIPMENT AND APPLIANCES SHALL BE | | | SIZED IN ACCORDANCE WITH ACCA MANUAL S OR OTHER | | | APPROVED SIZING METHODOLOGIES BASED ON BUILDING LOADS | | | CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR OTHER | | | APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. | | | | | | 3. PROVIDE DETAIL FOR C/U ANCHORAGE. | | | M1307.2 ANCHORAGE OF APPLIANCES. | | | APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE | | | FASTENED OR ANCHORED IN AN APPROVED MANNER. IN SEISMIC | | | DESIGN CATEGORIES D0, D1 AND D2, AND IN TOWNHOUSES IN | | | SEISMIC DESIGN CATEGORY C, WATER HEATERS AND THERMAL | | | STORAGE UNITS SHALL BE ANCHORED OR STRAPPED TO RESIST | | | HORIZONTAL DISPLACEMENT CAUSED BY EARTHQUAKE MOTION IN | | | ACCORDANCE WITH ONE OF THE FOLLOWING: | | | 1. 1. ANCHORAGE AND STRAPPING SHALL BE DESIGNED TO | | | RESIST A HORIZONTAL FORCE EQUAL TO ONE-THIRD OF THE | | | OPERATING WEIGHT OF THE WATER HEATER STORAGE TANK, | | | ACTING IN ANY HORIZONTAL DIRECTION. STRAPPING SHALL BE | | | AT POINTS WITHIN THE UPPER ONE-THIRD AND LOVER | | | ONE-THIRD OF THE APPLIANCE?S VERTICAL DIMENSIONS. AT | | | THE LOWER POINT, THE STRAPPING SHALL MAINTAIN A MINIMUM | | | DISTANCE OF 4 INCHES (102 MM) ABOVE THE CONTROLS. | | | 2. 2. THE ANCHORAGE STRAPPING SHALL BE IN ACCORDANCE | | | WITH THE APPLIANCE MANUFACTURER?S RECOMMENDATIONS. | | | | | | 4. PROVIDE DETAIL FOR LOCKING SERVICE PORTS. | | | M1411.8 LOCKING ACCESS PORT CAPS. | | | REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL | | | BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS OR | | | SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED | | | ACCESS. | | | EXCEPTION: NO LOCKING-TYPE TAMPER-RESISTANT CAPS ARE | | | REQUIRED IF PORTS ARE LOCATED INSIDE THE CONDENSING | | | UNIT CABINET. | | | | | | 5. PROVIDE CFM OF EXHAUST FANS. | | | 6. PROVIDE DETAIL OF EXHAUST FAN DISCHARGE TO EXTERIOR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-30 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-24 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-04-09 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-04-09 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2019-04-09 14:07:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL | | | MANUAL | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 1ST REVIEW: | | | A GAS METER IS SHOWN ON 5A. A SEPARATE GAS PERMIT IS | | | REQUIRED.A GAS PLAN AND PERMIT APPLICATION SHALL BE | | | PROVIDED FOR REVIEW. | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. SP SANITARY RISER DIAGRAM | | | A. PER FBC PL 701.3 AND FBC RES P2601.1, THE MAIN HOUSE | | | BUILDING DRAIN SHALL NOT RECIEVE THE DISCHARGE OF THE | | | GUEST HOUSE. THE GUEST HOUSE SHALL CONNECT TO A COMMON | | | BUILDING SEWER FOR ITSELF AND THE MAIN HOUSE. | | | B. DOUBLE SINK SHALL CONNECT DOWNSTREAM OF BATHROOM | | | GROUP PER FBC RES P3108.1. | | | C. BACK TO BACK SHOWER FIXTURE DRAINS SHALL EACH | | | CONNECT INDEPENDENTLY TO THE HORIZONTAL WET VENT PER | | | FBC RES P3108.1. | | | 2.PER WPB FBC 107.2.1, SHOW HOW HOT WATER SHALL BE | | | SUPPLIED IN COMPLIANCE WITH FBC PL 607.1 AND FBC RES | | | P2601.1 | | | | | | END OF COMMENTS | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-15 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-10 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-07-10 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-07-10 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2019-07-10 09:35:21 | 7/10/19 ROUTED TO HARD COPIES TO CTHROOP |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-06-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-26 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-20 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2019-06-24 09:11:31 | HARD COPY OF PLANS WITH ORIGINAL SIGNATURE AND SEAL | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-28 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-24 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2019-05-28 09:18:04 | HARD COPY OF PLANS WITH SIGNATURES AND SEALS REQUIRED | | | PRIOR TO PERMIT. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-15 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-15 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2019-04-15 15:03:25 | 1. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH | | | SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED | | | NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | 2. HARD COPY OF PLANS WITH ORIGINAL SIGNATURES AND | | | SEALS WILL BE REQUIRED AFTER ALL REVIEWS HAVE PASSED. | | | | | | | | 2019-04-10 13:12:45 | 4/10/19 HARD COPIES WITH CTHROOP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-06-25 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-06-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-06-25 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-25 10:21:30 | ******ZONING PROVISO******* | | | | | | PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE | | | FOLLOWING CONDITIONS SHALL BE ADDRESSED: | | | | | | 1. A LANDSCAPE PERMT, WHICH INCLUDED A LANDSCAPE PLAN, | | | SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. | | | | | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | | LANDSCAPE INSPECTION. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-06-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-20 09:31:22 | **************************************ZONING REVIEW | | | FAILED (REPEAT COMMENTS) ************************ | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-05-31 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-31 10:24:22 | **************************************ZONING REVIEW | | | FAILED (REPEAT COMMENTS) ************************ | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A | | | SEPARATE PERMIT. | | | | | | THE SIDE SETBACKS ARE NOT CONSISTENT ON BOUNDARY SURVEY | | | AND SITE PLAN. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-19 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-04-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-04-19 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2019-04-19 11:20:43 | **************************************ZONING REVIEW | | | FAILED************************ | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | THE PROPOSED DRIVEWAY, POOL, AND FENCE REQUIRE A | | | SEPARATE PERMIT. | | | | | | THE SIDE SETBACKS ARE NOT CONSISTENT ON BOUNDARY SURVEY | | | AND SITE PLAN. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | 2019-04-10 13:08:53 | SUBMITTAL HAS BEEN CHANGED FROM PAPER TO DIGITAL. CT |
|
|