Plan Review Details - Permit 19031376
Plan Review Stops For Permit 19031376
Review Stop G GAS REVIEW
Rev No 5 Status P Date 2021-07-08 Cont ID  
Sent By lcrespo Date 2021-07-08 Time 17:00 Rev Time 0.00
Received By lcrespo Date 2021-07-08 Time 17:00 Sent To  
Notes
2021-07-08 17:00:3307/08/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 4 Status F Date 2020-11-05 Cont ID  
Sent By jesmith Date 2020-11-05 Time 13:18 Rev Time 0.00
Received By jesmith Date 2020-11-05 Time 08:54 Sent To  
Notes
2020-11-05 13:10:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 SEE RECORD DRAWING MASTER PERMIT 18060100
  
 4TH REVIEW
 GAS COMMENTS:
  
  
 1.SUBMITTED GAS ISOMETRIC AND LOCATION PLAN SHOWS
 COOKTOP AT 57,000 BTUH. SUBMITTED SPECS-GAS OVEN HAS A
 TOTAL OF 83,000 BTUH
  
 2.TOTAL BTUH ON SUBMITTED PLAN IS 115,500. TOTAL IS
 ACTUALLY 141,500 BTUH.
  
 3.RISER DIAGRAM AND SIZING TABLES ONLY INDICATE PE
 PIPING WHICH IS THE UNDERGROUND. TRANSITION TO ABOVE
 GROUND AND CONNECTION PIPING SHALL COMPLY WITH FBC FG
 404.17.1 (PREMANUFACTURED ANODELESS RISERS OR SERVICE
 HEAD ADAPTER RISERS); PROVIDE MATERIAL SPEC AND SIZING
 TABLE FOR PIPING FROM SHUTOFF VALVE TO APPLIANCE.
  
 4.PROVIDE NOTE "INSTALL TRACER WIRE COMPLYING WITH FBC
 FG 404.17.3."
  
 5.REGARDING PREVIOUS REQUESTS FOR COMBUSTION AIR
 CALCULATIONS: SUBMITTED FLOOR PLAN DOES NOT CORRECTLY
 REFLECT RECORD DRAWING DIMENSIONS FOR THE
 KIT/LIVING/DINING. SUBMITTED PLAN FOR KIT/LIVING/DINING
 = ?18? FT X 14 FT 8 IN X 10 FT=2,640.6 CU FT
 RECORD PERMIT PLAN 18060100 INDICATES 10 FT CEILING
 HEIGHTS FOR THE AFFECTED ROOMS. YOU SHOULD REFER TO
 RECORD DRAWING MASTER PERMIT 18060100 PLAN SHEET A.2
 WHEN SUBMITTING CALCULATIONS.
 KIT/LIVING/DINING = 16 FT X 14 FT 8 IN X 10 FT=2,347.2
 CU FT
 FOYER=3 FT X 5 FT 9 IN X 10 FT=530.6 CU FT
 HALL=7 FT 7 IN X 5 FT 9 IN =172.5 CU FT
 TOTAL AVAILABLE COMBUSTION AIR =3,050.3 CU FT; REQUIRED
 IS 4,150 CU. FT. SEE BELOW
 SUBMITTED RANGE BTUH
 UPPER OVEN = 14,500 BTUH
 LOWER OVEN = 14,000 BTUH
 LR BURNER = 9,000 BTUH
 RR BURNER = 5,000 BTUH
 LF BURNER = 12,000 BTUH
 RF BURNER = 18,500 BTUH
 CENTER WARMER = 10,000 BTUH
 TOTAL APPLIANCE = 83,000 BTUH
 TOTAL COMBUSTION AIR REQUIRED CALCULATING PER FBC FG
 304.5.1 IS 4,150 CU FT.
  
 6. AS PREVIOUSLY NOTED, A REVISION SHALL BE IN PLACE
 FOR THE FINAL INSPECTION WHICH SHALL REMOVE THE HOOD
 VENT FROM RECORD DRAWING MASTER PERMIT 18060100 PLAN
 SHEET P.1.
  
 NOTE: PER WPB FBC 107.1, DESIGNER TO PROVIDE DIGITAL
 SIGNATURE IN ACCORDANCE WITH FAC AND FS OR SHALL
 PROVIDE WET SIGNED PAPER DOCUMEN(S)T PRIOR TO PERMIT
 ISSUANCE. CALL 561-805-6724 FOR ADDITIONAL INFORMATION.
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
 ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS
 REQUIRED BY FAC AND FS.
 ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE
 DESIGNER IN ACCORDANCE WITH FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-246-0882 MOBILE
  
 19031376 301 EDMOR RD

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2019-05-30 Cont ID  
Sent By thunt Date 2019-05-30 Time 07:15 Rev Time 0.00
Received By thunt Date 2019-05-30 Time 07:15 Sent To  
Notes
2019-05-30 07:02:51GAS 3RD REVIEW**DENIED**
  
  
 1) OK
  
 2) OK
  
 3) UNDER DESCRIPTION YOU STATE YOUR ARE DELETING THE
 GAS LAMPS. SUPPLY A GAS ISOMETRIC THAT DOES NOT SHOW
 THE GAS LAMPS ON IT. FBC 107.3.5
  
 4) PROVIDE DIMENSIONS AND SHOW HOW YOU CAME UP WITH THE
 4,500 CUBIT FEET OF MAKE UP AIR. PER THE APPROVED PLAN
 I CAN NOT SEE HOW THIS WAS DONE.
  
 5) A REVISION BY FINAL INSPECTION WILL BE REQUIRED
 REMOVING THE HOOD VENT FROM THE MASTER PERMIT #
 18060100 ON SHT. P1.
  
 6) PROVIDE WHICH MODEL BBQ YOU ARE USING AS NONE OF THE
 MODEL IN THE SPEC SHEETS SHOW THE 110,000BTU CALLED OUT
 ON YOUR PLAN
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 08:22 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 08:24 Sent To  
Notes
2019-05-20 08:22:37GAS 2ND REVIEW**DENIED**FL ST 553.80 (B)2B WITH RESPECT
 TO EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) OK
  
 2) 2ND REQUEST.VALUE OF JOB SEEMS LOW. PROVIDE BONA
 FIDE SIGNED CONTRACT. COST MUST INCLUDE THE GAS STOVE
 AND GAS LIGHTS. BBQ WAS INCLUDING UNDER MASTER PERMIT #
 18060100. W.P.B AMEND FBC 109.3
  
 3) 2ND REQEST. NO INFORMAION OTHER THEN A BASIC UL
 APPROVAL SUBMITTED FOR THE GAS LIGHTS.PROVIDE COMPLETE
 INSTALLATION MANUAL WHICH MUST ALSO INCLUDE THE MODEL
 OF UNITS TO MATCH UL APPROVAL. WHICH MODEL STOVE IS
 BEING USED?.SUBMIT MANUFACTURER'S SPECIFICATION SHEETS
 / INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. SEC.G2408.1.
  
 4) 2ND REQUEST. PROVIDE COMBUSTION AIR FOR THE STOVE.
 MASTER PERMIT #18060100 WAS APPROVED FOR ELC STOVE.
 2017 FBC-FUEL GAS SEC.304.9.3 OR FBCR G2407.9.3.
  
 5) 2ND REQUEST.PROVIDE HOOD EXHAUST VENTING DETAIL FOR
 THE BBQ AS CALLED OUT ON MASTER PERMIT # 18060100 SHT
 P1
  
 6) NEW COMMENT. SUBMIT 2 COPIES OF ALL SUBMITTAL
 DOCUMENTS. FBC 107.3.5
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-02 Cont ID  
Sent By thunt Date 2019-04-02 Time 13:51 Rev Time 0.00
Received By thunt Date 2019-04-02 Time 13:51 Sent To  
Notes
2019-04-02 13:51:31GAS 1ST REVIEW**DENIED**
  
 1) PERSON THAT DESIGNS PLAN SHALL TAKE RESPONSIBILITY
 BY SIGN AND DATED PLAN. F.S 471
  
 2) VALUE OF JOB SEEMS LOW. PROVIDE BONA FIDE SIGNED
 CONTRACT. COST MUST INCLUDE THE GAS STOVE AND LIGHTS.
 BBQ WAS INCLUDING UNDER MASTER PERMIT # 18060100. W.P.B
 AMEND FBC 109.3
  
 3) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1.
  
 4) MASTER PERMIT #18060100 WAS APPROVED FOR ELC STOVE.
 PROVIDE COMBUSTION AIR CALCULATIONS FOR THE GAS STOVE.
 2017 FBC-FUEL GAS SEC.304.9.3 OR FBCR G2407.9.3.
  
 5) PROVIDE HOOD EXHAUST VENTING DETAIL FOR THE BBQ AS
 CALLED OUT ON MASTER PERMIT # 18060100 SHT P1
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2021-07-08 Cont ID  
Sent By lcrespo Date 2021-07-08 Time 17:00 Rev Time 0.00
Received By lcrespo Date 2021-07-06 Time 10:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-11-05 Cont ID  
Sent By jesmith Date 2020-11-05 Time 13:20 Rev Time 0.00
Received By jesmith Date 2020-11-05 Time 13:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-30 Cont ID  
Sent By thunt Date 2019-05-30 Time 07:15 Rev Time 0.00
Received By thunt Date 2019-05-24 Time 14:00 Sent To  
Notes
2019-05-28 14:00:24RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 08:25 Rev Time 0.00
Received By thunt Date 2019-05-16 Time 13:37 Sent To  
Notes
2019-05-17 13:37:18RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-02 Cont ID  
Sent By thunt Date 2019-04-02 Time 13:51 Rev Time 0.00
Received By thunt Date 2019-03-29 Time 12:57 Sent To I
Notes
2019-04-01 12:57:42PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status N Date 2021-07-08 Cont ID  
Sent By lcrespo Date 2021-07-08 Time 16:58 Rev Time 0.00
Received By lcrespo Date 2021-07-08 Time 16:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-11-05 Cont ID  
Sent By jesmith Date 2020-11-05 Time 13:04 Rev Time 0.00
Received By jesmith Date 2020-11-05 Time 13:04 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-07-08 Cont ID  
Sent By lcrespo Date 2021-07-08 Time 16:59 Rev Time 0.00
Received By lcrespo Date 2021-07-08 Time 16:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By jesmith Date 2020-11-05 Time 13:19 Rev Time 0.00
Received By jesmith Date 2020-11-05 Time 13:04 Sent To  
Notes
2020-11-05 13:19:44PER WPB FBC 107.1, DESIGNER TO PROVIDE DIGITAL
 SIGNATURE IN ACCORDANCE WITH FAC AND FS OR SHALL
 PROVIDE WET SIGNED PAPER DOCUMENT(S) PRIOR TO PERMIT
 ISSUANCE. CALL 561-805-6724 FOR ADDITIONAL INFORMATION.