Plan Review Details - Permit 19031375
Plan Review Stops For Permit 19031375
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By cthroop Date 2019-06-12 Time 11:37 Rev Time 0.00
Received By cthroop Date 2019-06-12 Time 10:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-16 Cont ID  
Sent By cthroop Date 2019-05-16 Time 16:45 Rev Time 0.00
Received By cthroop Date 2019-05-08 Time 15:26 Sent To  
Notes
2019-05-16 17:05:51 
 BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE FINISH FLOOR ELEVATION.
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 2. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 3. ENERGY SUBMITTAL HAS WRONG SQ/FT. PROVIDE CORRECTED
 ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 4. ROOFING PERMIT REQUIRED.
 FBC 105
  
 5. PROVIDE DESIGN WIND PRESSURES FOR ALL WINDOW AND
 EXTERIOR DOOR OPENINGS.
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-14 Cont ID  
Sent By jpearson Date 2019-06-14 Time 11:21 Rev Time 0.00
Received By jpearson Date 2019-06-14 Time 11:21 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By jpearson Date 2019-05-07 Time 10:26 Rev Time 0.00
Received By jpearson Date 2019-05-07 Time 07:29 Sent To  
Notes
2019-05-07 10:26:35CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS AS PRESCRIBED IN THE FBC RESIDENTIAL. THIS SHOULD
 INCLUDE THE SQUARE FOOTAGE CALCULATION AND EACH
 ADDITIONAL LOAD SPECIFIED. THE MECHANICAL PLAN SHOWS 3
 AC SYSTEMS, BUT ONLY TWO ARE INCLUDED ON ELECTRICAL
 PLAN. THE LOAD CALCULAITON SHOULD INCLUDE THE LARGER OF
 THE AC LOAD AT 100%, OR 65% OF THE HEAT LOAD, WHICHEVER
 IS GREATER. NEC 220; FBC RE E3602.2
 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE, INCLUDING EACH LEVER OF THE STRUCTURE. FBC RE
 R314.3, R315.1; WPB FBC 107.2.1
 4. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN.
 PROVIDE CORRECTION FOR POWDER BATH. NEC 210.11(C)(3),
 210.52(D); FBC RE E3703.4, E3901.6
 5. DINING ROOM RECEPTACLE AND LIGHTING OUTLETS ARE
 SHOWN ON THE SAME CIRCUIT. PROVIDE CORRECTION. NEC
 210.52(B)(2); FBC RE E3703.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-06-14 Cont ID  
Sent By gjohnson Date 2019-06-14 Time 12:24 Rev Time 0.00
Received By gjohnson Date 2019-06-14 Time 12:24 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-11 Cont ID  
Sent By jesmith Date 2019-04-11 Time 14:19 Rev Time 0.00
Received By jesmith Date 2019-06-13 Time 16:16 Sent To  
Notes
2019-04-11 14:19:08CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL
 MANUAL
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 NFPA 54=NFPA 54 2018 FUEL GAS CODE
  
 1ST REVIEW: FUEL GAS
 A SEPARATE PERMIT IS REQUIRED
  
 COMMENTS: DENIED
  
 1. GAS RISER DIAGRAM TO SHOW ALL CUT LENGTHS INCLUDING
 DROP AND BRANCHES TO RANGE AND DRYER AS WELL AS
 UNDERGROUND TO FUTURE BBQ GRILL PER FBC RES G2413.4.1,
 G2413.4.2.PLEASE
 2. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR SAFEING OFF
 AND SECURING OF TERMINATION OF PIPING FOR FUTURE BBQ
 GRILL.PROVIDE NOTE AT VALVE UPSTREAM OF UNDERGROUND
 "VALVE SHALL BE PROVIDED WITH LOCK-OUT".
 3. PER WPB FBC 107.2.1 AND 107.3.5.3.13, SUBMIT
 CALCULATIONS FOR COMBUSTION AIR PER FBC RES G2407.1 AND
 G2439.4. WHERE COMBUSTION AIR IS PROVIDED BY THE
 BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR FBC RES
 G2407.9.3.
 4. PER WPB FBC 107.2.1 AND 107.3.5.3.13, SUBMIT
 MANUFACTURER?S SPECIFICATION SHEETS / INSTALLATION
 MANUAL FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS CODE
 SEC. 402.2, AND 301.3 OR 2017 FBC-RES. SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED. THE
 INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT
 SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC
 SEC.305.1, FBC-RES. SEC.G2408.1.
 5. PER NFPA 54 7.1.7.3 - AN ELECTRICALLY CONTINUOUS
 CORROSION-RESISTANT TRACER WIRE SUITABLE FOR DIRECT
 BURIAL (MINIMUM AWG 14) OR PRODUCT SPECIFICALLY
 DESIGNED FOR THAT PURPOSE, SHALL BE BURIED WITH THE
 POLYAMIDE OR POLYETHYLENE PIPE TO FACILITATE LOCATING
 THE PIPE.
 A. ONE END OF THE TRACER WIRE SHALL BE BROUGHT ABOVE
 GROUND AT A BUILDING WALL OR RISER.
 B. THE TRACER WIRE OR TAPE SHALL NOT BE IN DIRECT
 CONTACT WITH THE POLYAMIDE OR POLYETHYLENE PIPE.
  
  
 END OF COMMENTS
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-06-11 Cont ID  
Sent By fmittner Date 2019-06-11 Time 14:52 Rev Time 0.00
Received By fmittner Date 2019-06-11 Time 14:52 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-05-03 Cont ID  
Sent By fmittner Date 2019-05-03 Time 11:53 Rev Time 0.00
Received By fmittner Date 2019-05-03 Time 11:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-14 Cont ID  
Sent By gjohnson Date 2019-06-14 Time 12:25 Rev Time 0.00
Received By gjohnson Date 2019-05-31 Time 15:07 Sent To  
Notes
2019-06-03 15:07:19R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-16 Cont ID  
Sent By cthroop Date 2019-05-16 Time 17:08 Rev Time 0.00
Received By cthroop Date 2019-03-29 Time 13:31 Sent To  
Notes
2019-04-01 13:32:08R30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-06-18 Cont ID  
Sent By cthroop Date 2019-06-18 Time 16:36 Rev Time 0.00
Received By cthroop Date 2019-06-18 Time 16:36 Sent To  
Notes
2019-06-18 16:36:53MU-2019-018851-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-05-16 Cont ID  
Sent By cthroop Date 2019-05-16 Time 17:05 Rev Time 0.00
Received By cthroop Date 2019-05-08 Time 15:26 Sent To  
Notes
2019-05-16 17:06:37PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By cthroop Date 2019-06-12 Time 11:37 Rev Time 0.00
Received By cthroop Date 2019-06-12 Time 10:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-16 Cont ID  
Sent By cthroop Date 2019-05-16 Time 17:06 Rev Time 0.00
Received By cthroop Date 2019-05-08 Time 15:26 Sent To  
Notes
2019-05-16 17:08:51MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. INCORRECT SQ/FT STATED ON ENERGY SUBMITTAL. PROVIDE
 CORRECTED ENERY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-06-13 Cont ID  
Sent By jesmith Date 2019-06-13 Time 16:21 Rev Time 0.00
Received By jesmith Date 2019-06-13 Time 16:21 Sent To  
Notes
2019-06-13 16:21:18APPROVED
 PROVISO
 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM
 AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR
 BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL
 CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF
 THE VERTICAL SOIL STACK PER FBC RES P3108.1.
 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC
 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING
 FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC
 107.2.1. SAID SUBMITTAL SHALL BE APPROVED AND IN PLACE
 PRIOR TO FIRST PLUMBING INSPECTION.
 3. SEE WATER PIPING SYSTEM NOTE #5 ON P-3. WATER HAMMER
 ARRESTORS REQUIRED FOR AUTOMATIC CLOTHES WASHER.
 3. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
  
  
  
 19031375 1308 GEORGIA AVE
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-04-11 Cont ID  
Sent By jesmith Date 2019-04-11 Time 12:24 Rev Time 0.00
Received By jesmith Date 2019-04-09 Time 15:29 Sent To  
Notes
2019-04-11 12:02:11APPROVED
 PROVISO
 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM
 AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR
 BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL
 CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF
 THE VERTICAL SOIL STACK PER FBC RES P3108.1.
 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC
 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING
 FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC
 107.2.1. SAID SUBMITTAL SHALL BE APPROVED AND IN PLACE
 PRIOR TO FIRST PLUMBING INSPECTION.
 3. SEE WATER PIPING SYSTEM NOTE #5 ON P-3. WATER HAMMER
 ARRESTORS REQUIRED FOR AUTOMATIC CLOTHES WASHER.
 3. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
  
2019-04-11 11:38:53APPROVED
 PROVISO
 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM
 AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR
 BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL
 CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF
 THE VERTICAL SOIL STACK PER FBC RES P3108.1.
 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC
 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING
 FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC
 107.2.1. SAID SUBMITTAL TO BE APPROVED AND IN PLACE
 PRIOR TO FIRST PLUMBING INSPECTION.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By cthroop Date 2019-06-12 Time 11:31 Rev Time 0.00
Received By cthroop Date 2019-06-12 Time 10:05 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-05-16 Cont ID  
Sent By cthroop Date 2019-05-16 Time 16:26 Rev Time 0.00
Received By cthroop Date 2019-05-08 Time 15:26 Sent To  
Notes
2019-05-16 16:45:02BUILDING PLAN REVIEW - ROOFING
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. NOA 12-0229.02 FOR STANDING SEAM METAL ROOFING HAS
 EXPIRED. PROVIDE CURRENT NOA
  
 2. PROVIDE NOA FOR UNDERLAYMENT.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-06-19 Cont ID  
Sent By fmittner Date 2019-06-11 Time 14:53 Rev Time 0.00
Received By fmittner Date 2019-06-11 Time 14:53 Sent To  
Notes
2019-06-11 14:56:00COMMENT FROM ROUND 1 NOT ADDRESSED.
  
 SUBMIT LANDSCAPE AS A SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2019-05-03 Cont ID  
Sent By fmittner Date 2019-05-03 Time 11:53 Rev Time 0.00
Received By fmittner Date 2019-05-03 Time 11:53 Sent To  
Notes
2019-05-03 11:54:55REQUIRES SEPERATE LANDSCAPE PERMIT. CONTACT RAY
 CARANCI:822-1462


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved