| Plan Review Stops For Permit 19031375 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-12 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-12 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-16 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2019-05-16 17:05:51 | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE FINISH FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 2. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | 3. ENERGY SUBMITTAL HAS WRONG SQ/FT. PROVIDE CORRECTED | | | ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 4. ROOFING PERMIT REQUIRED. | | | FBC 105 | | | | | | 5. PROVIDE DESIGN WIND PRESSURES FOR ALL WINDOW AND | | | EXTERIOR DOOR OPENINGS. | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-14 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-14 |
Time |
11:21 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-05-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-07 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-07 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2019-05-07 10:26:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS AS PRESCRIBED IN THE FBC RESIDENTIAL. THIS SHOULD | | | INCLUDE THE SQUARE FOOTAGE CALCULATION AND EACH | | | ADDITIONAL LOAD SPECIFIED. THE MECHANICAL PLAN SHOWS 3 | | | AC SYSTEMS, BUT ONLY TWO ARE INCLUDED ON ELECTRICAL | | | PLAN. THE LOAD CALCULAITON SHOULD INCLUDE THE LARGER OF | | | THE AC LOAD AT 100%, OR 65% OF THE HEAT LOAD, WHICHEVER | | | IS GREATER. NEC 220; FBC RE E3602.2 | | | 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE, INCLUDING EACH LEVER OF THE STRUCTURE. FBC RE | | | R314.3, R315.1; WPB FBC 107.2.1 | | | 4. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION FOR POWDER BATH. NEC 210.11(C)(3), | | | 210.52(D); FBC RE E3703.4, E3901.6 | | | 5. DINING ROOM RECEPTACLE AND LIGHTING OUTLETS ARE | | | SHOWN ON THE SAME CIRCUIT. PROVIDE CORRECTION. NEC | | | 210.52(B)(2); FBC RE E3703.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-14 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-06-14 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-04-11 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-06-13 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2019-04-11 14:19:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL | | | MANUAL | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | NFPA 54=NFPA 54 2018 FUEL GAS CODE | | | | | | 1ST REVIEW: FUEL GAS | | | A SEPARATE PERMIT IS REQUIRED | | | | | | COMMENTS: DENIED | | | | | | 1. GAS RISER DIAGRAM TO SHOW ALL CUT LENGTHS INCLUDING | | | DROP AND BRANCHES TO RANGE AND DRYER AS WELL AS | | | UNDERGROUND TO FUTURE BBQ GRILL PER FBC RES G2413.4.1, | | | G2413.4.2.PLEASE | | | 2. PER WPB FBC 107.2.1, PROVIDE DETAIL FOR SAFEING OFF | | | AND SECURING OF TERMINATION OF PIPING FOR FUTURE BBQ | | | GRILL.PROVIDE NOTE AT VALVE UPSTREAM OF UNDERGROUND | | | "VALVE SHALL BE PROVIDED WITH LOCK-OUT". | | | 3. PER WPB FBC 107.2.1 AND 107.3.5.3.13, SUBMIT | | | CALCULATIONS FOR COMBUSTION AIR PER FBC RES G2407.1 AND | | | G2439.4. WHERE COMBUSTION AIR IS PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR FBC RES | | | G2407.9.3. | | | 4. PER WPB FBC 107.2.1 AND 107.3.5.3.13, SUBMIT | | | MANUFACTURER?S SPECIFICATION SHEETS / INSTALLATION | | | MANUAL FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2017 FUEL GAS CODE | | | SEC. 402.2, AND 301.3 OR 2017 FBC-RES. SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FGC | | | SEC.305.1, FBC-RES. SEC.G2408.1. | | | 5. PER NFPA 54 7.1.7.3 - AN ELECTRICALLY CONTINUOUS | | | CORROSION-RESISTANT TRACER WIRE SUITABLE FOR DIRECT | | | BURIAL (MINIMUM AWG 14) OR PRODUCT SPECIFICALLY | | | DESIGNED FOR THAT PURPOSE, SHALL BE BURIED WITH THE | | | POLYAMIDE OR POLYETHYLENE PIPE TO FACILITATE LOCATING | | | THE PIPE. | | | A. ONE END OF THE TRACER WIRE SHALL BE BROUGHT ABOVE | | | GROUND AT A BUILDING WALL OR RISER. | | | B. THE TRACER WIRE OR TAPE SHALL NOT BE IN DIRECT | | | CONTACT WITH THE POLYAMIDE OR POLYETHYLENE PIPE. | | | | | | | | | END OF COMMENTS | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-11 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-11 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-05-03 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-05-03 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-06-14 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-31 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-16 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-29 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-18 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-18 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2019-06-18 16:36:53 | MU-2019-018851-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-16 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2019-05-16 17:06:37 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-12 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-12 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-16 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2019-05-16 17:08:51 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. INCORRECT SQ/FT STATED ON ENERGY SUBMITTAL. PROVIDE | | | CORRECTED ENERY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-13 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-06-13 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-06-13 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-06-13 16:21:18 | APPROVED | | | PROVISO | | | 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM | | | AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR | | | BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL | | | CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF | | | THE VERTICAL SOIL STACK PER FBC RES P3108.1. | | | 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC | | | 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING | | | FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC | | | 107.2.1. SAID SUBMITTAL SHALL BE APPROVED AND IN PLACE | | | PRIOR TO FIRST PLUMBING INSPECTION. | | | 3. SEE WATER PIPING SYSTEM NOTE #5 ON P-3. WATER HAMMER | | | ARRESTORS REQUIRED FOR AUTOMATIC CLOTHES WASHER. | | | 3. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | | | | | | | | | | 19031375 1308 GEORGIA AVE | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-04-11 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-04-09 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2019-04-11 12:02:11 | APPROVED | | | PROVISO | | | 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM | | | AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR | | | BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL | | | CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF | | | THE VERTICAL SOIL STACK PER FBC RES P3108.1. | | | 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC | | | 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING | | | FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC | | | 107.2.1. SAID SUBMITTAL SHALL BE APPROVED AND IN PLACE | | | PRIOR TO FIRST PLUMBING INSPECTION. | | | 3. SEE WATER PIPING SYSTEM NOTE #5 ON P-3. WATER HAMMER | | | ARRESTORS REQUIRED FOR AUTOMATIC CLOTHES WASHER. | | | 3. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | | | 2019-04-11 11:38:53 | APPROVED | | | PROVISO | | | 1. SEE RED LINED COMMENTS ON P-4 SANITARY RISER DIAGRAM | | | AND P-2 SECOND FLOOR PLAN REGARDING THE SECOND FLOOR | | | BATHROOM, RM #201; THE TUB/SHOWER FIXTURE DRAIN SHALL | | | CONNECT TO THE HORIZONTAL WET VENT, NOT INTO THE TOP OF | | | THE VERTICAL SOIL STACK PER FBC RES P3108.1. | | | 2. PROVIDE BY DEFERRED SUBMITTAL AS ALLOWED BY WPB FBC | | | 107.3.4.1, MARKED UP MANUFACTURER'S SPEC SHEET, NOTING | | | FULL MODEL NUMBER, AND APPLICABLE SPECIFICS PER WPB FBC | | | 107.2.1. SAID SUBMITTAL TO BE APPROVED AND IN PLACE | | | PRIOR TO FIRST PLUMBING INSPECTION. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-06-12 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-06-12 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-16 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2019-05-16 16:45:02 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. NOA 12-0229.02 FOR STANDING SEAM METAL ROOFING HAS | | | EXPIRED. PROVIDE CURRENT NOA | | | | | | 2. PROVIDE NOA FOR UNDERLAYMENT. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-06-11 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-06-11 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2019-06-11 14:56:00 | COMMENT FROM ROUND 1 NOT ADDRESSED. | | | | | | SUBMIT LANDSCAPE AS A SEPARATE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-05-03 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-05-03 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2019-05-03 11:54:55 | REQUIRES SEPERATE LANDSCAPE PERMIT. CONTACT RAY | | | CARANCI:822-1462 |
|
|