| Plan Review Stops For Permit 19031348 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-16 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-04-29 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-04-29 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2019-04-29 14:45:17 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19031348 | | | ADD: 525 OKEECHOBEE BLVD. 8TH FLOOR RESTROOM RENOVATION | | | CONT: HOLT LEE | | | TEL: 954-725-4881 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. 04/29/2019 | | | ACTION: DENIED | | | | | | 1) THE BUILDING REVIEWER HAS THE SAME ISSUE AS THE | | | PLUMBING REVIEWER. | | | 1A) SHEET 005-A3.1 RESTROOM ELEVATIONS DOES NOT SHOW | | | COMPLIANCE WITH THE HEIGHT OF THE GRAB BARS. 2017 | | | FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB | | | BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE | | | THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING | | | SURFACE, NOT CENTERLINE. | | | | | | 1B) SHEET 005-A3.1 RESTROOM ELEVATIONS DOES NOT SHOW | | | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION | | | 604.5.1 THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 | | | MM) LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM | | | FROM THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) | | | MINIMUM FROM THE REAR WALL. | | | | | | 1C) SHEET 005-A3.1 RESTROOM ELEVATIONS DOES NOT SHOW | | | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE SECTION | | | 604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 | | | INCHES (915 MM) LONG MINIMUM AND EXTEND FROM THE | | | CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) | | | MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON | | | THE OTHER SIDE. | | | | | | 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-04-16 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-04-16 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-09 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2019-05-09 11:29:53 | FIRE PROVIOS 5/9/19 | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS AND BY CERTIFIED FA/FS CONTRACTORS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-04-03 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2019-04-03 10:34:49 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS AND BY CERTIFIED FA/FS CONTRACTORS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-01 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-04-29 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-29 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-04-29 |
Time |
14:45 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-18 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-18 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-03 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-03 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-15 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-15 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2019-04-15 12:08:02 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GRAB BARS SHALL COMPLY WITH FB ACC | | | | | | A) 604.5.1 SIDE WALL.THE SIDE WALL GRAB BAR SHALL BE 42 | | | INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE | | | REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR | | | WALL. | | | | | | B) 604.5.2 REAR WALL.THE REAR WALL GRAB BAR SHALL BE 36 | | | INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF | | | THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 | | | INCHES MINIMUM ON THE OTHER SIDE. | | | | | | C) 609.4 POSITION OF GRAB BARS.GRAB BARS SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE, | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-16 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-30 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-30 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2019-04-30 07:19:30 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ALL DIGITAL SEALS, SIGNATURES, AND TITLE BLOCKS ARE IN | | | ACCORDANCE WITH FS471, FS481. | | | | | | ANY NEW PAGES SUBMITTED NEXT REVIEW CYCLE WILL REQUIRE | | | VERIFICATION. | | | | | | | | 2019-04-18 17:38:56 | MECH SHEETS GOOD |
|
|