Plan Review Details - Permit 19031344
| Plan Review Stops For Permit 19031344 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-01 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-01 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-10 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-10 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2019-06-10 14:42:11 | ELECTRICAL UNDER PERMIT 19050284 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-06-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-07 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-07 |
Time |
09:38 |
Sent To |
P |
|
| Notes |
| 2019-06-07 09:38:32 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | BE ADVISED THAT THE PLAN SUBMITTED STATES THER EIS | | | ELECTRICAL WORK. THE PREVIOUS COMMENT BELOW HAVE NOT | | | BEEN ADDRESSED. PROVIDE CORRECTIONS AS NOTED BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY THE | | | PERSON RESPONSIBLE FOR THE DESIGN. WPB FBC 107.2.1, | | | 107.3.5; FS 471, 481 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. INDICATE WHICH BREAKERS ARE BEING REPLACED. | | | NEC 210.8, 210.12, 210.19, 210.20, 215.5, 408.4; WPB | | | FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 4. PER NEC: INTEGRITY OF ELECTRICAL EQUIPMENT AND | | | CONNECTIONS. INTERNAL PARTS OF ELECTRICAL EQUIPMENT, | | | INCLUDING BUSBARS, WIRING TERMINALS, INSULATORS, AND | | | OTHER SURFACES, SHALL NOT BE DAMAGED OR CONTAMINATED BY | | | FOREIGN MATERIALS SUCH AS PAINT, PLASTER, CLEANERS, | | | ABRASIVES, OR CORROSIVE RESIDUES. THERE SHALL BE NO | | | DAMAGED PARTS THAT MAY ADVERSELY AFFECT SAFE OPERATION | | | OR MECHANICAL STRENGTH OF THE EQUIPMENT SUCH AS PARTS | | | THAT ARE BROKEN; BENT; CUT; OR DETERIORATED BY | | | CORROSION, CHEMICAL ACTION, OR OVERHEATING. ELECTRICAL | | | PANEL SHOULD BE REPLACED. PROVIDE CORRECTION. NEC | | | 110.12(B) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-25 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-25 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2019-04-25 07:39:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY THE | | | PERSON RESPONSIBLE FOR THE DESIGN. WPB FBC 107.2.1, | | | 107.3.5; FS 471, 481 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. INDICATE WHICH BREAKERS ARE BEING REPLACED. | | | NEC 210.8, 210.12, 210.19, 210.20, 215.5, 408.4; WPB | | | FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 4. PER NEC: INTEGRITY OF ELECTRICAL EQUIPMENT AND | | | CONNECTIONS. INTERNAL PARTS OF ELECTRICAL EQUIPMENT, | | | INCLUDING BUSBARS, WIRING TERMINALS, INSULATORS, AND | | | OTHER SURFACES, SHALL NOT BE DAMAGED OR CONTAMINATED BY | | | FOREIGN MATERIALS SUCH AS PAINT, PLASTER, CLEANERS, | | | ABRASIVES, OR CORROSIVE RESIDUES. THERE SHALL BE NO | | | DAMAGED PARTS THAT MAY ADVERSELY AFFECT SAFE OPERATION | | | OR MECHANICAL STRENGTH OF THE EQUIPMENT SUCH AS PARTS | | | THAT ARE BROKEN; BENT; CUT; OR DETERIORATED BY | | | CORROSION, CHEMICAL ACTION, OR OVERHEATING. ELECTRICAL | | | PANEL SHOULD BE REPLACED. PROVIDE CORRECTION. NEC | | | 110.12(B) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-10 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-03 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2019-06-04 15:06:00 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-05-03 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-04-09 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-05-03 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-05-03 |
Time |
08:43 |
Sent To |
I |
|
| Notes |
| 2019-05-03 08:46:56 | NO MECHANICAL WORK REQUIRED, PER PLAN AND APPLICATION | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-06-10 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-06-10 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-06-10 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-16 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-16 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2019-04-16 14:53:03 | PLUMBING 1ST REVIEW**DENIED**NO INFORMATION REGRADING | | | PLUMBING WAS PROVIDE TO REVIEW | | | | | | PROVIDE LOCATION OF WATER HEATER AND SUPPLY | | | MANUFACTURES INSTALLATION MANUAL/ SPEC. FBC 107.3.5 | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | | | | |
|
|
|