Plan Review Details - Permit 19031259
| Plan Review Stops For Permit 19031259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-01 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-01 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2019-05-01 11:30:01 | RESIDENTIAL (R2) BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | | | | NOTE: ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | SEC. 801.3 FBC-EXISTING BUILDING. | | | | | | | | | 1- SCOPE OF WORK IS NOT CLEAR. PLANS SUBMITTED DON'T | | | PROVIDE DETAILS/SPECIFICATIONS SHOWING SCOPE OF WORK TO | | | BE PERFORMED. PROVIDE COMPLETE FLOOR PLANS DRAWN TO | | | SCALE AND SHOWING ALL THE UNITS AND CLEARLY SPECIFY THE | | | SCOPE OF WORK ON EACH UNIT. SEC. 107.2 CITY AMENDMENTS. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-18 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-18 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2019-04-18 12:50:46 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY | | | THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-29 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-03-29 11:50:36 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE IS INSUFFICIENT INFORMATION ON THE PLAN SHEETS | | | AS TO WHAT IS BEING DONE. | | | | | | PLEASE PROVIDE DETAILS AS TO WHAT WORK IS BEING DONE AT | | | EACH APARTMENT. | | | | | | | | | | | | 2) THERE IS ONLY ONE PLAN SHEET. | | | | | | ARE ALL THE UNITS THE SAME? | | | | | | IF THERE ARE ANY DIFFERENCES, EACH FLOOR LAYOUT SHALL | | | BE INCLUDED ON A SEPARATE SHEET. | | | | | | | | | | | | 3) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF | | | EACH UNIT. | | | | | | | | | | | | | | | 4) THERE ARE NO INDICATIONS OF SMOKE ALARMS. SMOKE | | | ALARMS ARE REQUIRED PER THE LIFE SAFETY CODE FOR | | | EXISTING APARTMENTS. | | | | | | PER NFPA 101 | | | | | | 31.3.4.5 SMOKE ALARMS. | | | 31.3.4.5.1* IN BUILDINGS OTHER THAN THOSE EQUIPPED | | | THROUGHOUT WITH AN | | | EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM, | | | SMOKE ALARMS | | | SHALL BE INSTALLED IN ACCORDANCE WITH 9.6.2.10, AS | | | MODIFIED BY 31.3.4.5.2, | | | OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE VICINITY | | | OF THE BEDROOMS | | | AND ON ALL LEVELS OF THE DWELLING UNIT, INCLUDING | | | BASEMENTS. | | | 31.3.4.5.2 SMOKE ALARMS REQUIRED BY 31.3.4.5.1 SHALL | | | NOT BE REQUIRED TO | | | BE PROVIDED WITH A SECONDARY (STANDBY) POWER SOURCE. | | | 31.3.4.5.3 IN BUILDINGS OTHER THAN THOSE EQUIPPED | | | THROUGHOUT WITH AN | | | EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM OR | | | A COMPLETE, | | | SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE | | | WITH 31.3.5, | | | SMOKE ALARMS SHALL BE INSTALLED IN EVERY SLEEPING AREA | | | IN | | | ACCORDANCE WITH 9.6.2.10, AS MODIFIED BY 31.3.4.5.4. | | | 31.3.4.5.4 SMOKE ALARMS REQUIRED BY 31.3.4.5.3 SHALL BE | | | PERMITTED TO BE | | | BATTERY POWERED. | | | | | | PLEASE INDICATE ON EACH PLAN SHEET THE LOCATION THE SA | | | AND HOW THEY WILL BE POWERED. | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-01 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-03-27 |
Time |
15:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-01 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-01 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-11 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-11 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2019-04-11 09:58:03 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE CLARIFY WHAT PLUMBING WORK IS BEING DONE | | | PROVIDE DETAILED SCOPE OF WORK, ARE YOU REMOVING THE | | | LAVATORY, KITCHEN SINK TOILET IN EACH UNIT THEN | | | REPLACING THE ANGLE STOP FOR EACH FIXTURE AND | | | RECONNECTING WITH NEW SUPPLY LINES. ARE YOU REPLACING | | | SHUT OFF ON WATER HEATER OR MAIN SHUT OFF FRO UNIT. | | | WILL THERE BE ANY WORK ON THE TUB AND SHOWER. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|