| 2019-04-30 07:54:33 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 19031173 |
| | REVIEWED: APRIL 29, 2019 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER PX4191 |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC[B] = FBC BUILDING |
| | FBC[EXISTING] = FBC EXISTING BUILDING |
| | FBC[A] = FBC ACCESSIBILITY |
| | FBC[E] = FBC ENERGY CONSERVATION |
| | FBC[R] = FBC RESIDENTIAL |
| | |
| | 1) 107.5.3 FBC[AMENDED] UPDATE CODE EDITION TO STATE |
| | CURRENT VERSION. 2017 FBC 6 TH EDITION. |
| | |
| | 2) R314.2 FBC[R] WHERE REQUIRED. SMOKE ALARMS SHALL BE |
| | PROVIDED IN ACCORDANCE WITH THIS SECTION. |
| | R314.2.2 FBC[R] ALTERATIONS, REPAIRS AND ADDITIONS. |
| | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A |
| | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE |
| | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| | LOCATED AS REQUIRED FOR NEW DWELLINGS. EXCEPTIONS: |
| | |
| | A. IN EACH SLEEPING ROOM. |
| | B.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE |
| | VICINITY OF THE BEDROOMS. |
| | C. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET |
| | (914 MM) HORIZONTALLY FROM THE DOOR OR OPENING OF A |
| | BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS |
| | WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY |
| | SECTION R314.3. |
| | |
| | R314.4 FBC[R] INTERCONNECTION. WHERE MORE THAN ONE |
| | SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN |
| | INDIVIDUAL DWELLING UNIT IN ACCORDANCE WITH SECTION |
| | R314.3, THE ALARM DEVICES SHALL BE INTERCONNECTED IN |
| | SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL |
| | ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING |
| | UNIT. PHYSICAL INTERCONNECTION OF SMOKE ALARMS SHALL |
| | NOT BE REQUIRED WHERE LISTED WIRELESS ALARMS ARE |
| | INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION OF ONE |
| | ALARM. EXCEPTION: INTERCONNECTION OF SMOKE ALARMS IN |
| | EXISTING AREAS SHALL NOT BE REQUIRED WHERE ALTERATIONS |
| | OR REPAIRS DO NOT RESULT IN REMOVAL OF INTERIOR WALL OR |
| | CEILING FINISHES EXPOSING THE STRUCTURE, UNLESS THERE |
| | IS AN ATTIC, CRAWL SPACE OR BASEMENT AVAILABLE THAT |
| | COULD PROVIDE ACCESS FOR INTERCONNECTION WITHOUT THE |
| | REMOVAL OF INTERIOR FINISHES. |
| | - |
| | |
| | ONE-FAMILY AND TWO-FAMILY DWELLINGS AND TOWNHOMES |
| | UNDERGOING A REPAIR, OR A LEVEL 1 ALTERATION AS DEFINED |
| | IN THE FLORIDA BUILDING CODE, MAY USE SMOKE ALARMS |
| | POWERED BY 10-YEAR NONREMOVABLE, NONREPLACEABLE |
| | BATTERIES IN LIEU OF RETROFITTING SUCH DWELLING WITH |
| | SMOKE ALARMS POWERED BY THE DWELLING?S ELECTRICAL |
| | SYSTEM. A BATTERY-POWERED SMOKE ALARM THAT IS NEWLY |
| | INSTALLED OR REPLACES AN EXISTING BATTERY-POWERED SMOKE |
| | ALARM AS A RESULT OF A LEVEL 1 ALTERATION MUST BE |
| | POWERED BY A NONREMOVABLE, NONREPLACEABLE BATTERY THAT |
| | POWERS THE ALARM FOR AT LEAST 10 YEARS. THE BATTERY |
| | REQUIREMENTS OF THIS SECTION DO NOT APPLY TO A FIRE |
| | ALARM, SMOKE DETECTOR, SMOKE ALARM, OR ANCILLARY |
| | COMPONENT THAT IS ELECTRONICALLY CONNECTED AS A PART OF |
| | A CENTRALLY MONITORED OR SUPERVISED ALARM SYSTEM, THAT |
| | USES A LOWPOWER, RADIO FREQUENCY WIRELESS COMMUNICATION |
| | SIGNAL; OR THAT CONTAINS MULTIPLE SENSORS, SUCH AS A |
| | SMOKE ALARM COMBINED WITH A CARBON MONOXIDE ALARM OR |
| | OTHER MULTISENSOR DEVICES, AND IS APPROVED AND LISTED |
| | BY A NATIONALLY RECOGNIZED TESTING LABORATORY. |
| | |
| | 3) 501.1.1 FBC[RE] ADDITIONS, ALTERATIONS, OR REPAIRS: |
| | GENERAL. ADDITIONS, ALTERATIONS, OR REPAIRS TO AN |
| | EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF |
| | SHALL COMPLY WITH SECTION R502, R503 OR R504. UNALTERED |
| | PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY |
| | SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. |
| | -WHICH METHOD OF COMPLIANCE IS BEING USED? |
| | |
| | 503.1.1 FBC[E] BUILDING ENVELOPE ASSEMBLIES THAT ARE |
| | PART OF THE ALTERATION SHALL COMPLY WITH SECTION |
| | R402.1.2 OR R402.1.4, SECTIONS R402.2.1 THROUGH |
| | R402.2.13, R402.3.1, R402.3.2, R402.4.3 AND R402.4.5. |
| | |
| | 4) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR |
| | TILE ROOFING (TILE,UNDERLAYMENT AND ATTACHMENT), OR |
| | INDICATE THAT YOU WOULD LIKE THEM DEFERED. |
| | |
| | NOTES: |
| | |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F |
| | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME |
| | [email protected] |
| | |
| | |
| | |