| Plan Review Stops For Permit 19031098 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-25 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-02-24 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-16 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-14 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-18 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2019-09-18 15:41:37 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SECTION VIEW OF EXTERIOR WALL. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. STATE R VALUE FOR WALL AND CEILING INSULATION ON | | | PLANS. | | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | | STORIES. | | | | | | 3. REMOVE DOCUMENTS FROM SUBMITTAL THAT DO NOT APPLY TO | | | THIS SCOPE OF WORK. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-30 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-30 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2019-04-30 13:54:19 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE HAS BEEN ADJUSTED FROM $30000 TO $66006 BASED | | | ON THE ICC BUILDING VALUATION DATA PUBLISHED FEB. 2019. | | | 539 SQ. FT. UNDER AIR X $122.46/SG.FT. = $66006. | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN. | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 3. PROVIDE FINISH FLOOR ELEVATION. | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 4. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | 5. OWNER/AGENT TO SIGN ENERGY SUBMITTAL. | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 6. PROVIDE PRODUCT APPROVALS FOR EXTERIOR DOORS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | | | 7. REFERENCE PLAN PAGE S2 - ROOF FRAMING PLAN IS | | | LABELED GUEST MECHANICAL PLAN. PLEASE CCCCLARIFY. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-02-24 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-02-24 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-24 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-24 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2019-12-24 09:00:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PANEL SCHEDULES SHOW AN ELECTRICAL TANKLESS WATER | | | HEATER, BUT THE PLAN SHOWS A GAS WATER HEATER. WHICH | | | WILL BE USED? PROVIDE ACCURATE LOAD CALCULATION BASED | | | ON THIS. NEC 220 FBC RE E3602.2 (LOAD CALCULATION STILL | | | NOT CORRECT. IF THE WATER HEATER IS GAS, WHY DOES IT | | | HAVE A 4500 VA LOAD ON A 30 AMP CIRCUIT? ALSO, SEE | | | COMMENT 13 BELOW.)(NOT ADDRESSED, NOT CORRECTED.) | | | 2. CORRECTED. | | | 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 4. CORRECTED. | | | 5. CORRECTED, NO FEED TO GUEST HOUSE SHOWN. | | | 6. CORRECTED, NO GUEST HOUSE SHOWN. | | | 7. CORRECTED, NO GUEST HOUSE SHOWN. | | | 8. CORRECTED. | | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (NOT CORRECTED.) | | | 10. CORRECTED, NO GUEST HOUSE SHOWN. | | | 11. CORRECTED, NO GUEST HOUSE SHOWN. | | | 12. CORRECTED, NO GUEST HOUSE SHOWN. | | | 13. PROVIDE ACCURATE LOAD CALCULATION. NEW CALCULATION | | | PROVIDED DID NOT INCLUDE THE RANGE, OR THE REQUIRED | | | 1500 VA FOR THE LAUNDRY CIRCUIT. NEC 220; FBC RE | | | E3602.2 (WASHER STILL SHOWS AS 1200 VA) | | | 14. PROVIDE CLARIFICATION. IS THERE NO MAIN HOUSE AND | | | SEPARATE GUEST HOUSE NOW? THE PLAN SHOWS ONLY ONE | | | STRUCTURE, WHAT HAPPENED TO THE LARGER STRUCTURE THAT | | | WAS ON THE PREVIOUS PLANS? WPB FBC 107.2.1 (NOT | | | ADDRESSED.) | | | 15. WHERE IS THE LOCATION OF THE AC EQUIPMENT? PROVIDE | | | GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | | 210.63; FBC RE E3901.12 (NOT PROVIDED.) | | | 16. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | (NOT PROVIDED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-17 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2019-09-17 12:21:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PANEL SCHEDULES SHOW AN ELECTRICAL TANKLESS WATER | | | HEATER, BUT THE PLAN SHOWS A GAS WATER HEATER. WHICH | | | WILL BE USED? PROVIDE ACCURATE LOAD CALCULATION BASED | | | ON THIS. NEC 220 FBC RE E3602.2 (LOAD CALCULATION STILL | | | NOT CORRECT. IF THE WATER HEATER IS GAS, WHY DOES IT | | | HAVE A 4500 VA LOAD ON A 30 AMP CIRCUIT? ALSO, SEE | | | COMMENT 13 BELOW.) | | | 2. CORRECTED. | | | 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 4. CORRECTED. | | | 5. CORRECTED, NO FEED TO GUEST HOUSE SHOWN. | | | 6. CORRECTED, NO GUEST HOUSE SHOWN. | | | 7. CORRECTED, NO GUEST HOUSE SHOWN. | | | 8. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 (SMOKE | | | ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM BATHROOM | | | DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET FROM ANY | | | MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE R314.3(4), | | | NFPA 72:29.8.3.4) | | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 (NOT CORRECTED.) | | | 10. CORRECTED, NO GUEST HOUSE SHOWN. | | | 11. CORRECTED, NO GUEST HOUSE SHOWN. | | | 12. CORRECTED, NO GUEST HOUSE SHOWN. | | | | | | NEW COMMENTS: | | | | | | 13. PROVIDE ACCURATE LOAD CALCULATION. NEW CALCULATION | | | PROVIDED DID NOT INCLUDE THE RANGE, OR THE REQUIRED | | | 1500 VA FOR THE LAUNDRY CIRCUIT. NEC 220; FBC RE | | | E3602.2 | | | 14. PROVIDE CLARIFICATION. IS THERE NO MAIN HOUSE AND | | | SEPARATE GUEST HOUSE NOW? THE PLAN SHOWS ONLY ONE | | | STRUCTURE, WHAT HAPPENED TO THE LARGER STRUCTURE THAT | | | WAS ON THE PREVIOUS PLANS? WPB FBC 107.2.1 | | | 15. WHERE IS THE LOCATION OF THE AC EQUIPMENT? PROVIDE | | | GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | | 210.63; FBC RE E3901.12 | | | 16. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-18 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-18 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2019-04-18 11:05:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PANEL SCHEDULES SHOW AN ELECTRICAL TANKLESS WATER | | | HEATER, BUT THE PLAN SHOWS A GAS WATER HEATER. WHICH | | | WILL BE USED? PROVIDE ACCRATE LOAD CALCULATION BASED ON | | | THIS. NEC 220 FBC RE E3602.2 | | | 2. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 5. RISER DIAGRAM SHOWS A 1 INCH CONDUIT FEEDING THE | | | GUEST HOUSE. BASED ON THE WIRE SIZES SHOWN, AND THE | | | FACT THAT SCHEDULE 80 PVC WOULD BE REQUIRED FOR THE | | | PARTS OF THE RUN THAT ARE SUBJECT TO PHYSICAL DAMAGE, | | | THIS CONDUIT DOES NOT HAVE THE CAPACITY FOR THE WIRES | | | SHOWN. PROVIDE CORRECTION. NEC CHAPTER 9, TABLES 4,5 | | | 6. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT FOR THE GUEST HOUSE. NEC 250.32; FBC RE3607.3 | | | 7. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL "C". NEC 225.31, | | | 225.32 | | | 8. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | 9. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 | | | 10. FOR GUEST HOUSE, PROVIDE GFCI PROTECTED RECEPTACLE | | | OUTLET FOR SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF | | | THE EQUIPMENT PER CODE. NEC 210.63; FBC RE E3901.12 | | | 11. FOR GUEST HOUSE, A MINIMUM OF ONE 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE | | | OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | | PROVIDE CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | 12. LIGHTING IN WALK IN CLOSETS APPEARS TO BE STANDARD | | | RECESS LIGHTS. PER CODE, LIGHTING WITH OPEN OR | | | PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR | | | LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-24 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-24 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2019-12-24 15:30:23 | PROVISO: | | | PROVIDE SIZING TABLE FBC FG TABLES 402.3(1-33) | | | SEPARATE PERMIT REQUIRED FOR GAS | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-27 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-27 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2019-08-27 12:33:07 | 1) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC-FUEL | | | GAS SECS. 401.4, 401.8, 402.3, AND TABLES 402.4 (1) | | | THRU 402.4 (37) OR 2017 FBC-RES. SEC. G2413.3, G2412.8, | | | G2413.1, G2413.2, & G2413.3. | | | | | | 2) A SEPARATE PERMIT IS REQUIRED FOR THE GAS | | | INSTALLATION. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-02-25 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-31 |
Time |
13:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-16 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-12-06 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-18 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-08-23 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-30 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-25 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2019-03-26 15:20:11 | R20 | | | **TRAVELLING TOGETHER - 19031092 & 19031098** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-05-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2020-05-27 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2020-05-27 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2020-05-27 13:38:14 | STAMP ON PLAN-OK | | | MU-20020-8132 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-30 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-30 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2019-04-30 13:56:32 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2020-01-03 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2020-01-03 |
Time |
14:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-09-11 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-09-11 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2019-09-11 14:24:56 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER 2017 FLORIDA BUILDING CODE | | | - BUILDING SEC 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-04-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-04-29 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2019-04-29 14:38:53 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - RETURNS TO UNDER SIZED PER 2017 - FLORIDA BUILDING | | | CODE - RESIDENTIAL SEC M1602.3 BALANCED RETURN AIR. | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-12-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-12-24 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-12-24 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-08-27 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-08-27 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2019-08-27 11:30:34 | 1.) THE ENERGY REPORT IS LISTING AN ELECTRIC TANKLESS | | | WATER HEATER BUT THE PLAN IS SHOWING A GAS TANKLESS | | | WATER HEATER. CLARIFY. WPB AMEND TO FBC 107.2.1. 2ND | | | REQUEST. | | | 2.) THE WATER SUPPLY VALVES FOR THE STACKED | | | WASHER/DRYER SHALL BE ACCESSIBLE PER 2017 FBC-RES. SEC. | | | P2903.9.3. | | | 3) SHT.P1 - THE PLUMBING RISER SHOWS A LAUNDRY TUB BUT | | | IT IS NOT SHOWN ON THE FLOOR PLAN, CLARIFY. | | | 4) THE WASHING MACHINE STACK IS NOT SHOWN ON THE | | | PLUMBING RISER. WPB AMEN. TO FBC SEC. 107.2.1. | | | 5) THE WASHING MACHINE STACK SHALL BE A MINIMUM OF 3 | | | INCHES. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-09 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-09 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2019-04-09 13:59:13 | 1ST REVIEW: 19031092 | | | | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE ENERGY REPORT IS LISTING AN ELECTRIC TANKLESS | | | WATER HEATER THE PLAN IS SHOWING A GAS TANKLESS WATER | | | HEATER PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | 2. ON THE GUEST HOUSE THE TANKLESS HEATER APPEARS TO BE | | | MOUNTED TO CLOSE TO THE WINDOW PROVIDE MANUFACTURE | | | INSTILLATION GUIDE TO DETERMINE EXACT DIMENSION. PER | | | WPB AMEND TO FBC 107.2.1 | | | 3. THE MAIN HOUSE SANITARY ISOMETRIC ON SHEET A5 ON THE | | | BATHROOM GROUP ONLY 1 FIXTURE IS ALLOWED TO DISCHARGE | | | UP STREAM OF THE WET VENT. PER FBC RES P3108.2.1 | | | 4. PLEASE SHOW THE SANITARY ISOMETRIC DRAWING ON THE | | | PLUMBING PAGE.PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-01-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-01-16 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-01-14 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-09-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-09-18 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-09-18 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2019-09-18 15:36:00 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW - COMMENTS FROM 1ST REVIEW HAVE NOT BEEN | | | ADDRESSED. | | | | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS, | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 2. SPECIFY ROOFING APPLICATION SYSTEM TO BE USED. RAS | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-30 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-30 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2019-04-30 13:57:27 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOFING SYSTEM | | | COMPONENTS, | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 2. SPECIFY ROOFING APPLICATION SYSTEM TO BE USED. RAS | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-02-11 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-02-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-02-11 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-01-13 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2020-01-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2020-01-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-13 14:16:47 | *****************************ZONING REVIEW | | | FAILED*********************************** | | | | | | | | | THE PROPOSED GUEST HOUSE WILL BE THE PRINCIPLE | | | STRUCTURE. | | | | | | (REPEAT COMMENT) PLEASE SUBMIT A SEPARATE LANDSCAPE AND | | | IRRIGATION PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. | | | | | | GROSS LOT SQUARE FOOTAGE MINUS | | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-09-05 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-09-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-09-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-05 15:13:49 | *****************************ZONING REVIEW | | | FAILED*********************************** | | | | | | | | | IS THE MAIN HOUSE NO LONGER BEING CONSTRUCTED? | | | | | | IF THE MAIN HOUSE IS NO LONGER BEING BUILT THE COTTAGE | | | NOW BECOMES THE PRINCIPAL STRUCTURE AND HAS TO MEET THE | | | FOLLOWING SETBACKS: | | | | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | | | | | FRONT: 25 FEET; | | | | | | REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER IS | | | LESS; | | | | | | SIDES: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | | | | (REPEAT COMMENT) PLEASE SUBMIT A SEPARATE LANDSCAPE AND | | | IRRIGATION PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. | | | | | | GROSS LOT SQUARE FOOTAGE MINUS | | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-04-04 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-04-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-04-04 16:27:46 | *****************************ZONING REVIEW | | | FAILED*********************************** | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. | | | | | | GROSS LOT SQUARE FOOTAGE MINUS | | | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR | | | PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | |
|
|