| Plan Review Stops For Permit 19030965 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-12-23 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-12-23 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-12-23 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-08-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-08-28 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-08-28 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2019-08-28 11:12:13 | PLEASE HAVE SOMEONE ORGANIZE THE MATERIALS IN THIS | | | PERMIT SO IT IS CLEAR WHAT IS INTENDED TO BE APART OF | | | THE PERMIT. | | | WE ONLY REQUIRE 2 COPIES OF EVERYTHING, BUT 3 CAN BE | | | PROVIDED AS WELL. | | | THE PROBLEM WITH DOCUMENTS IS THAT THERE ARE 2 COPIES | | | OF PRODUCT APPROVAL, 3 COPIES SITE PLAN, 6 COPIES OF | | | MOST EVERYTHING ELSE. | | | ALSO, WHEN DOCUMENTS WERE RE-SUBMITTED NO OLD MATERIALS | | | WERE REMOVED OR MARKED VOID, THERE ARE MULTIPLE | | | VERSIONS OF SURVEY AND OTHER MATERIALS SO IT IS HARD TO | | | KNOW WHAT IS CURRENT. | | | PLEASE GO THROUGH AND MAKE 2-3 SETS, LEAVE ONE SET OF | | | PREVIOUS MATERIALS MARKED VOID AND TAKE ANY ADDITIONAL | | | COPIES OUT OF SET. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-30 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-30 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2019-04-30 14:34:58 | 107.3.5 FBC[AMENDED] NO ADDITIONAL COMMENTS AT THIS | | | TIME. | | | BUILDING WILL NEED TO REVIEW CHANGES MADE TO SATIFY | | | OTHER REVIEW COMMENTS. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2020-01-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2020-01-14 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2020-01-14 |
Time |
13:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-12-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-12-31 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-12-31 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2019-12-31 14:58:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30 (LOAD CALCULATION | | | PROVIDED IS NOT PER CODE. IF THE EXISTING LOAD IS TO BE | | | DETERMINED BASED ON DEMAND, ALL OF THE ITEMS IN NEC | | | 220.87 ARE REQUIRED. ADDITIONALLY, THE SHEET THAT SHOWS | | | THE LOAD CALCULATION IS NOT SIGNED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTIONS.)(3RD | | | REVIEW: PER 220.87, THE LOAD MUST BE CALCULATED AT THE | | | MAXIMUM DEMAND PLUS 25%, PLUS THE NEW LOAD. | | | ADDITIONALLY, PROOF OF THE MAXIMUM DEMAND MUST BE | | | SUBMITTED. PROVIDE CORRECTION.) | | | 3. CORRECTED. | | | 4. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 5. RISER DIAGRAM SUPPLIED ON NEW PLAN DOES NOT STATE | | | THE SIZE OF THE ELECTRICAL SERVICE. WHAT IS THE | | | AMPERAGE RATING OF THIS SERVICE? NEC 215.5; WPB FBC | | | 107.2.1 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-09-11 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-09-11 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2019-09-11 11:54:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30 (LOAD CALCULATION | | | PROVIDED IS NOT PER CODE. IF THE EXISTING LOAD IS TO BE | | | DETERMINED BASED ON DEMAND, ALL OF THE ITEMS IN NEC | | | 220.87 ARE REQUIRED. ADDITIONALLY, THE SHEET THAT SHOWS | | | THE LOAD CALCULATION IS NOT SIGNED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTIONS.) | | | 3. SIGNATURE. PER THE WPB AMENDMENTS TO THE FBC, PLAN | | | (EACH SHEET OF BOTH COPIES) IS REQUIRED TO BEAR THE | | | NAME AND BE SIGNED AND SEALED BY A DESIGN PROFESSIONAL | | | OR SIGNED BY THE ELECTRICAL CONTRACTOR QUALIFIER. | | | PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481 | | | | | | NEW COMMENT: | | | | | | 4. PER THE WPB AMENDMENTS TO THE FBC, SUBMITTAL | | | DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, | | | STATEMENT OF SPECIAL INSPECTIONS, GEOTECHNICAL REPORT | | | AND OTHER DATA SHALL BE SUBMITTED IN TWO OR MORE SETS | | | WITH EACH PERMIT APPLICATION. THE SUBMISSION PROVIDED | | | IS NOT IN TWO COMPLETE SETS, THERE IS INFORMATION | | | SCATTERED THROUGHOUT THE PACKAGE. PROVIDE TWO COMPLETE | | | SETS WITH ALL RELATED INFORMATION FOR THE PROJECT. WPB | | | FBC 107.1 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-09 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-09 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2019-04-09 13:03:52 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63 | | | 2. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | | 3. PROVIDE CORRECTION FOR ENGINEERS SIGNATURE. PER FAC | | | 61G15-23.003 PROCEDURES FOR PHYSICALLY SIGNING AND | | | SEALING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS. | | | ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN | | | ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025, | | | F.S., AND RULE 61G15-23.001, F.A.C. MAY BE PHYSICALLY | | | SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE | | | PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. | | | (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE | | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE | | | USED. | | | (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY | | | CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY | | | OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE | | | REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL | | | NOT RENDER THE SIGNATURE ILLEGIBLE. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-01-07 |
Time |
14:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-21 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-01-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-01-08 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2020-01-09 14:16:51 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-01-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-01-07 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-12-19 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-09-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-08-19 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-30 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-20 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2020-01-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-01-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-01-02 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-09-13 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-09-13 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2019-09-13 08:36:08 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030965 | | | 9/13/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | COMMENTS FROM THE 1ST REVIEW PRINTED BELOW HAVE NOT | | | BEEN ADDRESSED. | | | | | | 1) REFER TO SECTION 61G15-23.002 FAC: THE ASHRAE-90 | | | 2013 COMPLIANCE DATA REPORT FOR THE WALK-IN FREEZER | | | SHALL BE SIGNED AND SEALED BY THE ENGINEER WHO PREPARED | | | THE DOCUMENT- RANDY HERBERT. | | | | | | 2) INDICATE HOW THE OUTDOOR WALK-IN FREEZER WILL BE | | | PROTECTED FROM DAMAGE SUCH AS VEHICLE IMPACT- SECTION | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | NEW COMMENT | | | | | | 1) A NEW SET OF FLORIDA MANUFACTURED APPROVALS FOR THE | | | WALK-IN HAVE BEEN SUBMITTED. PLEASE REMOVE THE ORIGINAL | | | OUTDATED FLORIDA APPROVALS FROM THE PERMIT FILE, AND | | | PROVIDE ONLY TWO OR MORE DUPLICATE SETS OF PLANS AND | | | SPECIFICATIONS. THE CURRENT PERMIT SUBMITTAL IS | | | UNACCEPTABLE PER SECTION 107.2.1 WPB. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-11 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-11 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2019-04-11 13:08:36 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030965 | | | 4/11/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO SECTION 61G15-23.002 FAC: THE ASHRAE-90 | | | 2013 COMPLIANCE DATA REPORT FOR THE WALK-IN FREEZER | | | SHALL BE SIGNED AND SELAED BY THE ENGINEER WHO | | | POREPARED THE DOCUMENT- RANDY HERBERT. | | | | | | 2) INDICATE HOW THE OUTDOOR WALK-IN FREEZER WILL BE | | | PROTECTED FROM DAMAGE SUCH AS VEHICLE IMPACT- SECTION | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-01-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2020-01-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2020-01-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-03 15:24:23 | REFERENCE: WESTWARD PLAZA MINOR DSI AMENDMENT (PB | | | 1520M). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-08-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-08-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-08-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-23 15:06:19 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PER SECTION 94-36(F)(3) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS), THE PROPOSED SCOPE OF | | | WORK REQUIRES AN AMENDMENT TO THE APPROVED WESTWARD | | | PLAZA DEVELOPMENT OF SIGNIFICANT IMPACT (DSI) PRIOR TO | | | THE SUBMISSION OF A BUILDING PERMIT. PLEASE CONTACT THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION FOR | | | INFORMATION. [4/3/19 REPEAT COMMENT] | | | | | | | | | | | | NOTES: | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: GC/WESTWARD PLAZA DSI | | | | | | * CALLED (LEFT V/M) AND EMAILED CONTRACTOR DAVID | | | BORSDORF ON 8/23/19 TO RETURN CALL TO CLARIFY THE | | | PROCESS OF THE MINOR DSI AMENDMENT. | | | | | | * OUTDOOR FREEZER STORAGE WILL REQUIRE SCREENING (I.E. | | | LANDSCAPED HEDGE ALONG THE SIDES OF THE FREEZER). A | | | LANDSCAPE PLAN WILL BE REQUIRED WITH THE DSI AMENDMENT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-04-03 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2019-03-29 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-04-03 09:06:18 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PER SECTION 94-36(F)(3) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS), THE PROPOSED SCOPE OF | | | WORK REQUIRES AN AMENDMENT TO THE APPROVED WESTWARD | | | PLAZA DEVELOPMENT OF SIGNIFICANT IMPACT (DSI) PRIOR TO | | | THE SUBMISSION OF A BUILDING PERMIT. PLEASE CONTACT THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION FOR | | | INFORMATION. | | | | | | 2.) WHAT ARE THE SPECIFICATION FOR THE PROPOSED | | | STAND-ALONE FREEZER? (I.E. HEIGHT, WIDTH, ETC.) | | | | | | | | | NOTES: | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: GC/WESTWARD PLAZA DSI | | | |
|
|