| Plan Review Stops For Permit 19030938 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-05-28 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-05-28 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-25 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-04-26 08:17:45 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 19030938 | | | REVIEWED: APRIL 26, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | ADVISORY 505.1 GENERAL. HANDRAILS ARE REQUIRED ON RAMP | | | RUNS WITH A RISE GREATER THAN 6 INCHES (150 MM) (SEE | | | 405.8) AND ON CERTAIN STAIRWAYS (SEE 504).HANDRAILS ARE | | | NOT REQUIRED ON WALKING SURFACES WITH RUNNING SLOPES | | | LESS THAN 1:20. | | | | | | HOWEVER, HANDRAILS ARE REQUIRED TO COMPLY WITH 505 WHEN | | | THEY ARE PROVIDED ON WALKING SURFACES WITH RUNNING | | | SLOPES LESS THAN 1:20 (SEE 403.6). SECTIONS 505.2, | | | 505.3, AND 505.10 DO NOT APPLY TO HANDRAILS PROVIDED ON | | | WALKING SURFACES WITH RUNNING SLOPES LESS THAN 1:20 AS | | | THESE SECTIONS ONLY REFERENCE REQUIREMENTS FOR RAMPS | | | AND STAIRS. | | | | | | PLEASE REVIEW IF A 505 HANDRAILS APPLIES INSTEAD OF | | | GUARDRAIL. ALTHOUGH A HANDRAIL MAY NOT BE REQUIRED THE | | | SECOND PART OF 505.1 STATES WHEN THEY ARE PROVIDED THEY | | | WILL MEET HANDRAIL REQUIREMENTS OF 505. | | | | | | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. | | | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE | | | REQUIRED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-06-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-26 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-26 |
Time |
09:26 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-06-03 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-06-03 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-16 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-16 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2019-04-16 10:50:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | 2. RISER DIAGRAM SHOWS A METER CAN ON EXTERIOR OF | | | BUILDING FEEDING PANELS THAT ARE BEING RELOCATED. | | | CONDUCTORS THAT DO NOT HAVE OVERCURRENT PROTECTION ARE | | | NOT PERMITTED TO BE RUN THROUGH A BUILDING IN THIS | | | MANNER. PROVIDE CORRECTION. NEC 230.70 | | | 3. IF SERVICE IS TO BE RE-DESIGNED TO CORRECT COMMENT | | | 1, PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 | | | 4. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9 | | | 5. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 6. MAINS FOR SERVICE SHALL BE GROUPED. PROVIDE | | | CORRECTION. NEC 230.72 | | | 7. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | | EQUIPMENT PER CODE. NEC 210.63 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-05-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-24 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-25 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-25 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2019-03-25 11:37:53 | PERMIT # 19030938 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-06-03 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-06-03 |
Time |
14:32 |
Sent To |
PC |
|
| Notes |
| 2019-06-03 14:32:58 | ALL GLASS SHALL BE CLEAR OR LOW-E. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-04-11 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-04-11 |
Time |
14:48 |
Sent To |
PC |
|
| Notes |
| 2019-04-11 14:49:06 | THE PERMIT HAS APPROVED THE PERMIT WITH THE FOLLOWING | | | CONDITIONS: | | | | | | 1. ALL WINDOWS SHALL HAVE CLEAR GLASS OR LOW-E GLASS. | | | | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-24 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2019-06-25 14:53:32 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-05-22 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-20 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-25 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2019-04-26 08:29:18 | NO CHANGE IN OCCUPANCY OR SQ. FOOTAGE. | | | IMPACT MAY BE REVIEWED AT TENANT BUILD OUT OF THESE | | | SPACES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-06-28 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-06-28 |
Time |
12:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-06-03 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-06-03 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2019-06-03 16:03:46 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030938 | | | 6/3/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE RESUBMITTED PLANS AND NEW AC CALCULATIONS SHALL | | | BEAR RAISED OR INK SEALS AND WET SIGNATURES. DIGITAL | | | SEALS AND SIGNATURES ARE ACCEPTABLE FOR ELECTRONIC PLAN | | | SUBMITTALS- SEE SECTIONS 61G15-23.002 AND 61G15-23.005 | | | FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-11 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-11 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2019-04-11 16:43:43 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030938 | | | 4/11/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW RTU'S IN ACCORDANCE WITH SECTION C403.2.1 FBC EC. | | | | | | 2) M-1: PROVIDE THE WIND LOAD DESIGN CRITERIA USED FOR | | | INSTALLATION OF THE RTU'S- SECTION 310.15 FBC M, AND | | | SECTION 1609 FBC B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-15 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-15 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-04-15 11:41:38 | PROVISO: PROVIDE AN APPROVED PLAN REVISION WITH AN | | | ISOMETRIC DRAWING AT TIME OF 1ST INSPECTION |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-04-11 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-04-11 |
Time |
14:48 |
Sent To |
PC |
|
| Notes |
|
|