 |
Plan Review Details - Permit 19030897
| Plan Review Stops For Permit 19030897 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-08-05 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-29 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2019-07-29 13:32:12 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 5TH BUILDING REVIEW DENIED; APPROVAL IS PENDING | | | CORRECTION OF ITEMS FROM LAST REVIEWS LISTED BELOW: | | | | | | 5C. FBC B 1007.1.1/FBC B 107.2.1 PROVIDE THE TRAVEL | | | DISTANCE ON PAGE LS 1.0 FROM THE 2ND MEANS OF EGRESS | | | FROM THE CONFERENCE ROOM. | | | FBC B 107.2.1 PLEASE REVIEW AND CORRECT THE PAGE SCALES | | | ON PAGES A 2.0 AND A 3.0 FROM 1/8"= 1' TO WHAT APPEARS | | | TO BE 1/4"=1'. | | | | | | PROVISO: | | | 1. PROVIDE MANUFACTURER'S SPECIFICATIONS FOR SHOWER | | | SEAT INSTALLATION AT TIME OF INSPECTION. | | | 2. PROVIDE SEPERATE PERMIT FOR CONSTRUCTION OF TENANT | | | SEPERATION WALLS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-17 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-06-17 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2019-06-17 16:33:23 | | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19030897 | | | ADD: 1411 N. FLAGLER DRIVE SUITE 8900 | | | CONT: LEIGHTON MCGINN | | | TEL: 561863-4455 | | | E-MAIL: [email protected] | | | | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | | | | 4TH REVIEW | | | DATE: 06/17/19 | | | ACTION: DENIED | | | | | | ORIGINAL COMMENT: | | | 1) THE COVERSHEET UNDER APPLICABLE CODES LIST THE | | | BUILDING TYPE AS A TYPE V(A) UNSPRINKLERED. PLEASE | | | REVIEW THE BUILDING AND SITE. THE VICTOR FARRIS | | | BUILDING IS A 9 STORY HIGHRISE, FULLY SPRINKLERED. | | | PLEASE UPDATE THE PLANS TO THE CORRECT BUILDING TYPE. | | | SEE THE 2017 FBC-B TABLE 504.4. | | | | | | RESPONSE: | | | REPEAT COMMENT. FOUR TIMES. PLANS SUBMITTED SHOW SAME | | | INFORMATION FROM LAST BUILDING REVIEW. | | | BUILDING TYPE WAS REVISED TO TYPE II(A)SPRINKLERED. | | | THIS IS INCORRECT AGAIN. ACCORDING TO TABLE 504.4 | | | FBC-BUILDING THE MAXIMUM NUMBER OF STORIES ABOVE GRADE | | | PLANE ALLOWED FOR TYPE II(A) SPRINKLERED BUILDING FOR A | | | BUSINESS OCCUPANCY IS 6 STORIES. SEE TABLE 504.4 AND | | | REVISE AS REQUIRED. | | | | | | | | | 2)OK. | | | | | | 3)OK. | | | | | | 4) OK. | | | | | | 5) LIFE SAFETY SHEET: | | | | | | 5A)OK. | | | | | | 5B)OK. | | | | | | ORIGINAL COMMENT: | | | 5C) THE OTHER ISSUE WITH THE RECEPTION/ CONFERENCE ROOM | | | OCCUPANT LOAD IS THE COMMON PATH OF TRAVEL. | | | SEE TABLE 1006.2.1 THE MAXIMUM OCCUPANT LOAD OF 30 | | | OCCUPANTS IN THE ASSEMBLY OCCUPANCY THE COMMON PATH OF | | | TRAVEL IS LIMITED TO 75 FEET AND THE MAXIMUM OCCUPANT | | | LOAD OF 49, TABLE 1006.1.2. | | | | | | PLEASE REVIEW SECTION 1006.2.1 EGRESS BASED ON OCCUPANT | | | LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO | | | EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE | | | PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON | | | PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES | | | LISTED IN TABLE 1006.2.1. THE EXCEPTION FORI-2 DOES NOT | | | WORK SINCE THIS IS NOT A CARE SUITE WITHIN A HOSPITAL. | | | PLEASE PROVIDE 2 EXIT ACCESS DOORWAY THAT WILL BE IN | | | COMPLIANCE WITH FBC-B 1007.1.1 EXCEPTION2. | | | FBC-B 1007.1.1 EXCEPTION2. WHERE A BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. | | | | | | THERE ARE 2 AREAS OF CONCERN, 1ST IN THE CONFERENCE | | | ROOM ITSELF REQUIRING 2 MEANS OF EGRESS, OUTSWING DOOR | | | REQUIRED. THE 2ND AREA IS WITHIN THE TENANT SPACE | | | ITSELF THE TOTAL OCCUPANT LOAD IS OVER 49 REQUIRING | | | ALSO 2 MEANS OF EGRESS. | | | | | | RESPONSE: | | | REPEAT COMMENT. FOUR TIMES. (ARCHITECT TO SEE FLORIDA | | | STATUTE 553.80(2)(B)). FEES WILL APPLY. | | | | | | TENANT SPACE PROPOSED SECOND MEANS OF EGRESS DOESN'T | | | COMPLY WITH EXCEPTION #2 OF SEC. 1007.1.1 FBC-BUILDING. | | | THE SEPARATION DISTANCE SHALL BE NOT LESS THAN | | | ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL | | | DIMENSION OF THE AREA SERVED. THE DIAGONAL DISTANCE | | | SHOWN IS 95'-0". ONE THIRD 1/3 OF 95'-0" IS 31'-8". THE | | | DISTANCE BETWEEN THE TWO EXITS IS +/- 22'-0". | | | THEREFORE, IT DOESN'T COMPLY. REVISE AS REQUIRED. | | | NOTE: THE DISTANCE IS MEASURED THE SAME WAY THE | | | DIAGONAL DIMENSION IS DIMENSIONED. IS THE DISTANCE | | | BETWEEN THE TWO DOORS NOT THE TRAVEL DISTANCE BETWEEN | | | THE TWO DOORS AS SHOWN ON PLAN. REVISE AS REQUIRED. | | | ALSO, PLEASE CLEAN UP INFORMATION ON PLANS. THERE ARE | | | SOME DIMENSIONS THAT CORRESPOND TO PREVIOUS PLANS THAT | | | NO LONGER APPLIES. FOR EXAMPLE, SEE THE TRAVEL DISTANCE | | | 95'-0" SHOWN BY THE CONFERENCE ROOM AND TOTAL TRAVEL | | | DISTANCE SHOWN BY THE ENTRY DOOR. PLEASE MAKE SURE ALL | | | REVISED FLOOR PLANS MATCH. OFFICE LAYOUT SHOWN BY THE | | | SECOND PROPOSED EXIT DOESN'T MATCH. | | | | | | NOTE: SCALE SHOWN ON SHEET A2.0 AND A3.0 IS INCORRECT. | | | REVISE AS REQUIRED. | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | | | | | | | 6) SHEET A6.0 ACCESSIBLE FEATURES: | | | | | | THE FOLLOWING COMMENTS APPLY TO THE SHOWER COMPARTMENT | | | BASED ON REVISIONS DONE TO ADDRESSEES ORIGINAL COMMENTS | | | REGARDING ACCESSIBLE FEATURES. | | | | | | SHOWER COMPARTMENT (SEC. 608 FBC-ACCESSIBILITY): | | | A)OK. | | | | | | B) OK. | | | | | | ORIGINAL COMMENT: | | | C) IT IS NOT CLEAR WHAT IS THE 2'-8" DIMENSION SHOWN BY | | | THE SHOWER AREA. IS THERE A PARTITION BETWEEN THE WATER | | | CLOSET AND THE SHOWER?. SEC. 107.2.1 CITY AMENDMENTS | | | AND SEC. 608.2.2.1 | | | | | | RESPONSE: | | | STILL NO CLEAR WHAT IS THE 2'-8" DIMENSION FOR?. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | D) ENLARGED FLOOR PLAN ON SHEET A6.0 AND ACCESSIBLE | | | SHOWER DETAIL SHOWN ON SAME PAGE DON'T MATCH. SEE | | | LOCATION OF GRAB BARS. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | DETAILS DON'T MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | E) GRAB BARS LOCATION SHOWN ON FLOOR PLAN DOESN'T | | | COMPLY WITH SEC. 608.3. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | STILL DON'T COMPLY. SEC. 107.2.1 CITY AMENDMENTS. | | | NOTE: TO AVOID CONFLICT/CONFUSION IS BETTER TO | | | COORDINATE WITH PLUMBING REVIEW COMMENTS. | | | | | | ORIGINAL COMMENT: | | | F) SHOWER COMPARTMENT SEAT: SHOW COMPLIANCE WITH THE | | | REQUIREMENTS OF SEC. 610.3 INCLUDING THE CLEARANCE AT | | | THE COMPARTMENT ENTRY, WALL CLEARANCES FOR L SHAPED | | | SEATS AND STRUCTURAL STRENGTH. | | | | | | RESPONSE: | | | STILL DON'T COMPLY. SEC. 107.2.1 CITY AMENDMENTS. | | | NOTE: TO AVOID CONFLICT/CONFUSION IS BETTER TO | | | COORDINATE WITH PLUMBING REVIEW COMMENTS. | | | | | | ORIGINAL COMMENT: | | | 7) SHEET A7.0 DETAIL C IS TAKEN IN THE CONFERENCE ROOM | | | BREAK AREA SINK. THE HEIGHT OF THE CABINET COUNTER TOP | | | IS 36 INCHES FROM THE FLOOR PLUS THE THICKNESS OF THE | | | SINK RIM. PLEASE SHOW COMPLIANCE WITH: | | | | | | 2017 FBC-ACCESS. CODE SECTION 606 LAVATORIES AND SINKS> | | | 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. SAME SHEET SUBMITTED. | | | DETAIL SOWS 2'-10" HEIGHT TO THE TOP OF THE COUNTER. | | | THE RIM OF THE SINK IS HIGHER. THE DIMENSION IS TO BE | | | TAKEN TO THE HIGHER OF THE RIM OR COUNTER SURFACE. | | | REVISE AS REQUIRED. | | | | | | ORIGINAL COMMENT: | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | RESPONSE: | | | THERE IS IS NO RESPONSE LETTER FROM THE ARCHITECT. EVEN | | | THOUGH A RESPONSE LETTER IS NOT MANDATORY IT IS VERY | | | HELPFUL IN EXPEDITING THE REVIEW PROCESS. | | | | | | NEW COMMENTS: | | | ORIGINAL COMMENT: | | | 1- PLANS ARE NOT CLEAR IN SHOWING THE SCOPE OF WORK TO | | | BE DONE TO THE TENANT SPACES AND THEY DON'T SHOW THE | | | NEW WALLS SEPARATING THE TENANTS. EXISTING BUILDING | | | PLAN (SHEET A1.0) AND DEMOLITION PLAN (SHEET A1.1) SHOW | | | WHAT SEEMS TO BE THE PROPOSED TENANT SEPARATION WALL, | | | BUT PLANS DON'T SHOW SCOPE OF WORK. CLEARLY IDENTIFY | | | WHAT IS GOING TO BE DEMOLISHED TO ALLOW FOR NEW TENT | | | SEPARATION WALLS AND PROVIDE DETAILS/SPECIFICATIONS FOR | | | SCOPE OF WORK ON EACH SIDE OF THE TENANT SEPARATION | | | WALLS. | | | NOTE: SEPARATE SUB-PERMITS MAY BE REQUIRED FOR PROPER | | | INSPECTIONS ON BOTH SIDES OF TENANTS. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | RESPONSE: | | | NOT ADDRESSED AT ALL. | | | THERE IS IS NO RESPONSE LETTER FROM THE ARCHITECT. EVEN | | | THOUGH A RESPONSE LETTER IS NOT MANDATORY IT IS VERY | | | HELPFUL IN EXPEDITING THE REVIEW PROCESS. | | | | | | ORIGINAL COMMENT: | | | 2- CLARIFY WHY PROPOSED FLOOR PLAN ON SHEET A2.0 ONLY | | | SHOWS AN ACCESSIBLE COUNTER AT THE CHECK OUT AREA AND | | | NO ONE AT THE CHECK IN AREA. CHECK IN COUNTER AREA IS | | | ALSO USED TO WRITE CHECKS, ETC. SEC. 227.3 | | | FBC-ACCESSIBILITY. | | | | | | RESPONSE: | | | NOT ADDRESSED AT ALL. | | | THERE IS IS NO RESPONSE LETTER FROM THE ARCHITECT. EVEN | | | THOUGH A RESPONSE LETTER IS NOT MANDATORY IT IS VERY | | | HELPFUL IN EXPEDITING THE REVIEW PROCESS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-03 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-06-03 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2019-06-03 09:07:29 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19030897 | | | ADD: 1411 N. FLAGLER DRIVE SUITE 8900 | | | CONT: LEIGHTON MCGINN | | | TEL: 561863-4455 | | | E-MAIL: [email protected] | | | | | | | | | NOTE: | | | IT LOOKS LIKE PLANS WERE NOT REVISED TO ADDRESS THE | | | COMMENTS. SAME PLANS REVIEWED LAST TIME WERE | | | RE-SUBMITTED. BUILDING REVIEW FAILED AGAIN . SAME | | | COMMENTS APPLY. | | | | | | | | | | | | | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | | | | | | | | | | | | | 3RD REVIEW | | | DATE: 06/03/19 | | | ACTION: DENIED | | | | | | ORIGINAL COMMENT: | | | 1) THE COVERSHEET UNDER APPLICABLE CODES LIST THE | | | BUILDING TYPE AS A TYPE V(A) UNSPRINKLERED. PLEASE | | | REVIEW THE BUILDING AND SITE. THE VICTOR FARRIS | | | BUILDING IS A 9 STORY HIGHRISE, FULLY SPRINKLERED. | | | PLEASE UPDATE THE PLANS TO THE CORRECT BUILDING TYPE. | | | SEE THE 2017 FBC-B TABLE 504.4. | | | | | | RESPONSE: | | | BUILDING TYPE WAS REVISED TO TYPE II(A)SPRINKLERED. | | | THIS IS INCORRECT AGAIN. ACCORDING TO TABLE 504.4 | | | FBC-BUILDING THE MAXIMUM NUMBER OF STORIES ABOVE GRADE | | | PLANE ALLOWED FOR TYPE II(A) SPRINKLERED BUILDING FOR A | | | BUSINESS OCCUPANCY IS 6 STORIES. SEE TABLE 504.4 AND | | | REVISE AS REQUIRED. | | | | | | | | | 2)OK. | | | | | | 3)OK. | | | | | | 4) OK. | | | | | | 5) LIFE SAFETY SHEET: | | | | | | 5A)OK. | | | | | | 5B)OK. | | | | | | ORIGINAL COMMENT: | | | 5C) THE OTHER ISSUE WITH THE RECEPTION/ CONFERENCE ROOM | | | OCCUPANT LOAD IS THE COMMON PATH OF TRAVEL. | | | SEE TABLE 1006.2.1 THE MAXIMUM OCCUPANT LOAD OF 30 | | | OCCUPANTS IN THE ASSEMBLY OCCUPANCY THE COMMON PATH OF | | | TRAVEL IS LIMITED TO 75 FEET AND THE MAXIMUM OCCUPANT | | | LOAD OF 49, TABLE 1006.1.2. | | | | | | PLEASE REVIEW SECTION 1006.2.1 EGRESS BASED ON OCCUPANT | | | LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO | | | EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE | | | PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON | | | PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES | | | LISTED IN TABLE 1006.2.1. THE EXCEPTION FORI-2 DOES NOT | | | WORK SINCE THIS IS NOT A CARE SUITE WITHIN A HOSPITAL. | | | PLEASE PROVIDE 2 EXIT ACCESS DOORWAY THAT WILL BE IN | | | COMPLIANCE WITH FBC-B 1007.1.1 EXCEPTION2. | | | FBC-B 1007.1.1 EXCEPTION2. WHERE A BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. | | | | | | THERE ARE 2 AREAS OF CONCERN, 1ST IN THE CONFERENCE | | | ROOM ITSELF REQUIRING 2 MEANS OF EGRESS, OUTSWING DOOR | | | REQUIRED. THE 2ND AREA IS WITHIN THE TENANT SPACE | | | ITSELF THE TOTAL OCCUPANT LOAD IS OVER 49 REQUIRING | | | ALSO 2 MEANS OF EGRESS. | | | | | | RESPONSE: | | | PROPOSED SECOND MEANS OF EGRESS DOESN'T COMPLY WITH | | | EXCEPTION #2 OF SEC. 1007.1.1 FBC-BUILDING. THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. THE DIAGONAL DISTANCE SHOWN IS 95'-0". | | | ONE THIRD 1/3 OF 95'-0" IS 31'-8". THE DISTANCE BETWEEN | | | THE TWO EXITS IS +/- 22'-0". THEREFORE, IT DOESN'T | | | COMPLY. REVISE AS REQUIRED. | | | NOTE: THE DISTANCE IS MEASURED THE SAME WAY THE | | | DIAGONAL DIMENSION IS DIMENSIONED. IS THE DISTANCE | | | BETWEEN THE TWO DOORS NOT THE TRAVEL DISTANCE BETWEEN | | | THE TWO DOORS AS SHOWN ON PLAN. REVISE AS REQUIRED. | | | ALSO, PLEASE CLEAN UP INFORMATION ON PLANS. THERE ARE | | | SOME DIMENSIONS THAT CORRESPOND TO PREVIOUS PLANS THAT | | | NO LONGER APPLIES. FOR EXAMPLE, SEE THE TRAVEL DISTANCE | | | 95'-0" SHOWN BY THE CONFERENCE ROOM AND TOTAL TRAVEL | | | DISTANCE SHOWN BY THE ENTRY DOOR. PLEASE MAKE SURE ALL | | | REVISED FLOOR PLANS MATCH. OFFICE LAYOUT SHOWN BY THE | | | SECOND PROPOSED EXIT DOESN'T MATCH. | | | | | | NOTE: SCALE SHOWN ON SHEET A2.0 AND A3.0 IS INCORRECT. | | | REVISE AS REQUIRED. | | | | | | 6) SHEET A6.0 ACCESSIBLE FEATURES: | | | | | | THE FOLLOWING COMMENTS APPLY TO THE SHOWER COMPARTMENT | | | BASED ON REVISIONS DONE TO ADDRESSEES ORIGINAL COMMENTS | | | REGARDING ACCESSIBLE FEATURES. | | | | | | SHOWER COMPARTMENT (SEC. 608 FBC-ACCESSIBILITY): | | | A)THE SHOWER IN THE TOILET WITH SHOWER BATHROOM DOESN'T | | | SEEM TO COMPLY WITH THE MINIMUM SHOWER COMPARTMENT SIZE | | | (30 INCHES BY 60 INCHES). SEC. 608.2. REVISE AS | | | REQUIRED. | | | | | | B) THE SHOWER DOESN'T HAVE THE 30 INCHES BY 60 INCHES | | | CLEARANCE REQUIRED BY SEC. 608.2.2.1 | | | | | | C) IT IS NOT CLEAR WHAT IS THE 2'-8" DIMENSION SHOWN BY | | | THE SHOWER AREA. IS THERE A PARTITION BETWEEN THE WATER | | | CLOSET AND THE SHOWER?. SEC. 107.2.1 CITY AMENDMENTS | | | AND SEC. 608.2.2.1 | | | | | | D) ENLARGED FLOOR PLAN ON SHEET A6.0 AND ACCESSIBLE | | | SHOWER DETAIL SHOWN ON SAME PAGE DON'T MATCH. SEE | | | LOCATION OF GRAB BARS. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | E) GRAB BARS LOCATION SHOWN ON FLOOR PLAN DOESN'T | | | COMPLY WITH SEC. 608.3. REVISE AS REQUIRED. | | | | | | F) SHOWER COMPARTMENT SEAT: SHOW COMPLIANCE WITH THE | | | REQUIREMENTS OF SEC. 610.3 INCLUDING THE CLEARANCE AT | | | THE COMPARTMENT ENTRY, WALL CLEARANCES FOR L SHAPED | | | SEATS AND STRUCTURAL STRENGTH. | | | | | | 7) SHEET A7.0 DETAIL C IS TAKEN IN THE CONFERENCE ROOM | | | BREAK AREA SINK. THE HEIGHT OF THE CABINET COUNTER TOP | | | IS 36 INCHES FROM THE FLOOR PLUS THE THICKNESS OF THE | | | SINK RIM. PLEASE SHOW COMPLIANCE WITH: | | | | | | 2017 FBC-ACCESS. CODE SECTION 606 LAVATORIES AND SINKS> | | | 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | RESPONSE: | | | DETAIL SOWS 2'-10" HEIGHT TO THE TOP OF THE COUNTER. | | | THE RIM OF THE SINK IS HIGHER. THE DIMENSION IS TO BE | | | TAKEN TO THE HIGHER OF THE RIM OR COUNTER SURFACE. | | | REVISE AS REQUIRED. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | NEW COMMENTS: | | | 1- PLANS ARE NOT CLEAR IN SHOWING THE SCOPE OF WORK TO | | | BE DONE TO THE TENANT SPACES AND THEY DON'T SHOW THE | | | NEW WALLS SEPARATING THE TENANTS. EXISTING BUILDING | | | PLAN (SHEET A1.0) AND DEMOLITION PLAN (SHEET A1.1) SHOW | | | WHAT SEEMS TO BE THE PROPOSED TENANT SEPARATION WALL, | | | BUT PLANS DON'T SHOW SCOPE OF WORK. CLEARLY IDENTIFY | | | WHAT IS GOING TO BE DEMOLISHED TO ALLOW FOR NEW TENT | | | SEPARATION WALLS AND PROVIDE DETAILS/SPECIFICATIONS FOR | | | SCOPE OF WORK ON EACH SIDE OF THE TENANT SEPARATION | | | WALLS. | | | NOTE: SEPARATE SUB-PERMITS MAY BE REQUIRED FOR PROPER | | | INSPECTIONS ON BOTH SIDES OF TENANTS. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 2- CLARIFY WHY PROPOSED FLOOR PLAN ON SHEET A2.0 ONLY | | | SHOWS AN ACCESSIBLE COUNTER AT THE CHECK OUT AREA AND | | | NO ONE AT THE CHECK IN AREA. CHECK IN COUNTER AREA IS | | | ALSO USED TO WRITE CHECKS, ETC. SEC. 227.3 | | | FBC-ACCESSIBILITY. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-20 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-17 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2019-05-20 14:04:18 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19030897 | | | ADD: 1411 N. FLAGLER DRIVE SUITE 8900 | | | CONT: LEIGHTON MCGINN | | | TEL: 561863-4455 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: RIDAY. MAY 17TH, 2019. | | | ACTION: DENIED | | | | | | ORIGINAL COMMENT: | | | 1) THE COVERSHEET UNDER APPLICABLE CODES LIST THE | | | BUILDING TYPE AS A TYPE V(A) UNSPRINKLERED. PLEASE | | | REVIEW THE BUILDING AND SITE. THE VICTOR FARRIS | | | BUILDING IS A 9 STORY HIGHRISE, FULLY SPRINKLERED. | | | PLEASE UPDATE THE PLANS TO THE CORRECT BUILDING TYPE. | | | SEE THE 2017 FBC-B TABLE 504.4. | | | | | | RESPONSE: | | | BUILDING TYPE WAS REVISED TO TYPE II(A)SPRINKLERED. | | | THIS IS INCORRECT AGAIN. ACCORDING TO TABLE 504.4 | | | FBC-BUILDING THE MAXIMUM NUMBER OF STORIES ABOVE GRADE | | | PLANE ALLOWED FOR TYPE II(A) SPRINKLERED BUILDING FOR A | | | BUSINESS OCCUPANCY IS 6 STORIES. SEE TABLE 504.4 AND | | | REVISE AS REQUIRED. | | | | | | | | | 2)OK. | | | | | | 3)OK. | | | | | | 4) OK. | | | | | | 5) LIFE SAFETY SHEET: | | | | | | 5A)OK. | | | | | | 5B)OK. | | | | | | ORIGINAL COMMENT: | | | 5C) THE OTHER ISSUE WITH THE RECEPTION/ CONFERENCE ROOM | | | OCCUPANT LOAD IS THE COMMON PATH OF TRAVEL. | | | SEE TABLE 1006.2.1 THE MAXIMUM OCCUPANT LOAD OF 30 | | | OCCUPANTS IN THE ASSEMBLY OCCUPANCY THE COMMON PATH OF | | | TRAVEL IS LIMITED TO 75 FEET AND THE MAXIMUM OCCUPANT | | | LOAD OF 49, TABLE 1006.1.2. | | | | | | PLEASE REVIEW SECTION 1006.2.1 EGRESS BASED ON OCCUPANT | | | LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO | | | EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE | | | PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON | | | PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES | | | LISTED IN TABLE 1006.2.1. THE EXCEPTION FORI-2 DOES NOT | | | WORK SINCE THIS IS NOT A CARE SUITE WITHIN A HOSPITAL. | | | PLEASE PROVIDE 2 EXIT ACCESS DOORWAY THAT WILL BE IN | | | COMPLIANCE WITH FBC-B 1007.1.1 EXCEPTION2. | | | FBC-B 1007.1.1 EXCEPTION2. WHERE A BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. | | | | | | THERE ARE 2 AREAS OF CONCERN, 1ST IN THE CONFERENCE | | | ROOM ITSELF REQUIRING 2 MEANS OF EGRESS, OUTSWING DOOR | | | REQUIRED. THE 2ND AREA IS WITHIN THE TENANT SPACE | | | ITSELF THE TOTAL OCCUPANT LOAD IS OVER 49 REQUIRING | | | ALSO 2 MEANS OF EGRESS. | | | | | | RESPONSE: | | | PROPOSED SECOND MEANS OF EGRESS DOESN'T COMPLY WITH | | | EXCEPTION #2 OF SEC. 1007.1.1 FBC-BUILDING. THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. THE DIAGONAL DISTANCE SHOWN IS 95'-0". | | | ONE THIRD 1/3 OF 95'-0" IS 31'-8". THE DISTANCE BETWEEN | | | THE TWO EXITS IS +/- 22'-0". THEREFORE, IT DOESN'T | | | COMPLY. REVISE AS REQUIRED. | | | NOTE: THE DISTANCE IS MEASURED THE SAME WAY THE | | | DIAGONAL DIMENSION IS DIMENSIONED. IS THE DISTANCE | | | BETWEEN THE TWO DOORS NOT THE TRAVEL DISTANCE BETWEEN | | | THE TWO DOORS AS SHOWN ON PLAN. REVISE AS REQUIRED. | | | ALSO, PLEASE CLEAN UP INFORMATION ON PLANS. THERE ARE | | | SOME DIMENSIONS THAT CORRESPOND TO PREVIOUS PLANS THAT | | | NO LONGER APPLIES. FOR EXAMPLE, SEE THE TRAVEL DISTANCE | | | 95'-0" SHOWN BY THE CONFERENCE ROOM AND TOTAL TRAVEL | | | DISTANCE SHOWN BY THE ENTRY DOOR. PLEASE MAKE SURE ALL | | | REVISED FLOOR PLANS MATCH. OFFICE LAYOUT SHOWN BY THE | | | SECOND PROPOSED EXIT DOESN'T MATCH. | | | | | | NOTE: SCALE SHOWN ON SHEET A2.0 AND A3.0 IS INCORRECT. | | | REVISE AS REQUIRED. | | | | | | 6) SHEET A6.0 ACCESSIBLE FEATURES: | | | | | | THE FOLLOWING COMMENTS APPLY TO THE SHOWER COMPARTMENT | | | BASED ON REVISIONS DONE TO ADDRESSEES ORIGINAL COMMENTS | | | REGARDING ACCESSIBLE FEATURES. | | | | | | SHOWER COMPARTMENT (SEC. 608 FBC-ACCESSIBILITY): | | | A)THE SHOWER IN THE TOILET WITH SHOWER BATHROOM DOESN'T | | | SEEM TO COMPLY WITH THE MINIMUM SHOWER COMPARTMENT SIZE | | | (30 INCHES BY 60 INCHES). SEC. 608.2. REVISE AS | | | REQUIRED. | | | | | | B) THE SHOWER DOESN'T HAVE THE 30 INCHES BY 60 INCHES | | | CLEARANCE REQUIRED BY SEC. 608.2.2.1 | | | | | | C) IT IS NOT CLEAR WHAT IS THE 2'-8" DIMENSION SHOWN BY | | | THE SHOWER AREA. IS THERE A PARTITION BETWEEN THE WATER | | | CLOSET AND THE SHOWER?. SEC. 107.2.1 CITY AMENDMENTS | | | AND SEC. 608.2.2.1 | | | | | | D) ENLARGED FLOOR PLAN ON SHEET A6.0 AND ACCESSIBLE | | | SHOWER DETAIL SHOWN ON SAME PAGE DON'T MATCH. SEE | | | LOCATION OF GRAB BARS. REVISE AS REQUIRED TO MATCH. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | E) GRAB BARS LOCATION SHOWN ON FLOOR PLAN DOESN'T | | | COMPLY WITH SEC. 608.3. REVISE AS REQUIRED. | | | | | | F) SHOWER COMPARTMENT SEAT: SHOW COMPLIANCE WITH THE | | | REQUIREMENTS OF SEC. 610.3 INCLUDING THE CLEARANCE AT | | | THE COMPARTMENT ENTRY, WALL CLEARANCES FOR L SHAPED | | | SEATS AND STRUCTURAL STRENGTH. | | | | | | 7) SHEET A7.0 DETAIL C IS TAKEN IN THE CONFERENCE ROOM | | | BREAK AREA SINK. THE HEIGHT OF THE CABINET COUNTER TOP | | | IS 36 INCHES FROM THE FLOOR PLUS THE THICKNESS OF THE | | | SINK RIM. PLEASE SHOW COMPLIANCE WITH: | | | | | | 2017 FBC-ACCESS. CODE SECTION 606 LAVATORIES AND SINKS> | | | 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | RESPONSE: | | | DETAIL SOWS 2'-10" HEIGHT TO THE TOP OF THE COUNTER. | | | THE RIM OF THE SINK IS HIGHER. THE DIMENSION IS TO BE | | | TAKEN TO THE HIGHER OF THE RIM OR COUNTER SURFACE. | | | REVISE AS REQUIRED. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | NEW COMMENTS: | | | 1- PLANS ARE NOT CLEAR IN SHOWING THE SCOPE OF WORK TO | | | BE DONE TO THE TENANT SPACES AND THEY DON'T SHOW THE | | | NEW WALLS SEPARATING THE TENANTS. EXISTING BUILDING | | | PLAN (SHEET A1.0) AND DEMOLITION PLAN (SHEET A1.1) SHOW | | | WHAT SEEMS TO BE THE PROPOSED TENANT SEPARATION WALL, | | | BUT PLANS DON'T SHOW SCOPE OF WORK. CLEARLY IDENTIFY | | | WHAT IS GOING TO BE DEMOLISHED TO ALLOW FOR NEW TENT | | | SEPARATION WALLS AND PROVIDE DETAILS/SPECIFICATIONS FOR | | | SCOPE OF WORK ON EACH SIDE OF THE TENANT SEPARATION | | | WALLS. | | | NOTE: SEPARATE SUB-PERMITS MAY BE REQUIRED FOR PROPER | | | INSPECTIONS ON BOTH SIDES OF TENANTS. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 2- CLARIFY WHY PROPOSED FLOOR PLAN ON SHEET A2.0 ONLY | | | SHOWS AN ACCESSIBLE COUNTER AT THE CHECK OUT AREA AND | | | NO ONE AT THE CHECK IN AREA. CHECK IN COUNTER AREA IS | | | ALSO USED TO WRITE CHECKS, ETC. SEC. 227.3 | | | FBC-ACCESSIBILITY. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-03-27 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-03-26 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2019-03-27 07:59:54 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 19030897 | | | ADD: 1411 N. FLAGLER DRIVE SUITE 8900 | | | CONT: LEIGHTON MCGINN | | | TEL: 561863-4455 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 26/ 2019 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET UNDER APPLICABLE CODES LIST THE | | | BUILDING TYPE AS A TYPE V(A) UNSPRINKLERED. PLEASE | | | REVIEW THE BUILDING AND SITE. THE VICTOR FARRIS | | | BUILDING IS A 9 STORY HIGHRISE, FULLY SPRINKLERED. | | | PLEASE UPDATE THE PLANS TO THE CORRECT BUILDING TYPE. | | | SEE THE 2017 FBC-B TABLE 504.4. | | | | | | 2) THE COVERSHEET UNDER THE HEADING OF GENERAL NOTE 10 | | | INDICATES FIRE RETARDANT TREATED AS PER THE REQUIREMENT | | | OF THE 2017 FBC-RESIDENTIAL CODE. PLEASE REMOVE THIS | | | NOTE SINCE IT HAS NOTHING TO DO WITH THIS REVIEW, THIS | | | IS A COMMERCIAL HIGH-RISE. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 3) SHEET A2.0 HAS (2) NOTES THAT DEAL WITH THE | | | RESIDENTIAL CODE FBC-R 308. PLEASE REMOVE ALL NOTES | | | DEALING WITH THE ONE & TWO FAMILY RESIDENTIAL CODE. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 4) SHEET A2.0 ALSO HAS NOTES REFERRING TO THE FEDERAL | | | A.D.A. AND THE STATE OF FLORIDA ACCESSIBILITY CODE. | | | THEN LIST VARIOUS CODE SECTIONS 4.1.6, 4.1.9, 4.13.6AND | | | ALL OF THE S. F. B. C. (SOUTH FLORIDA BUILDING CODE). | | | | | | 4A) SECTIONS 4.1.6, 4.1.9, 4.13.6 ARE OUT OF THE ADA, | | | NOT THE FLORIDA ACCESSIBILITY CODE. SECTIONS 4.1.6 & | | | 4.1.9 ARE MENTIONED A SECOND TIME. PLEASE IF | | | REFERENCING THE 2017 FBC-ACCESS. CODE PLEASE USE THE | | | CORRECT CODE SECTIONS, NOT THE ADA. | | | | | | 4B) THE S. F. B. C. (SOUTH FLORIDA BUILDING CODE) ARE | | | NO LONGER A CURRENT CODE. YOU ONLY REFER TO THE HIGH | | | VELOCITY HURRICANE ZONE WHEN WORKING IN EITHER DADE OR | | | BROWARD COUNTIES. SEE THE 2017 FBC-B DEFINITIONS | | | CHAPTER 2. HIGH VELOCITY HURRICANE ZONE. THIS ZONE | | | CONSISTS OF BROWARD AND DADE COUNTIES. | | | | | | 5) LIFE SAFETY SHEET: | | | | | | 5A) THE OCCUPANCY LOAD CLASSIFICATION CHART NEEDS TO BE | | | REVIEWED FOR CODE COMPLIANCE. THE OFFICE AND EXAM | | | ROOMS? NEED BOTH TO BE FIGURED AT 100 SQ. FT. /PER | | | OCCUPANT, NOT THE 240 GROSS FOR THE EXAM ROOMS. | | | PLEASE REVIEW IN THE 2017 FBC-B TABLE 1004.1.2. THE 240 | | | GROSS IS USED IN INSTITUTIONAL AREAS SUCH AS INPATIENT | | | TREATMENT AREAS NOT IN A BUSINESS OCCUPANCY. SO THE | | | TOTAL AREA OF THE BUSINESS PORTION OF THE TENANT SPACE | | | IS 2407 SQ. FT. OR 25 OCCUPANTS, YOU ALWAYS ROUND UP, | | | YOU NEVER HAVE PARTIAL OCCUPANTS, SEE BOAF INFORMAL | | | INTERPRETATIONS. | | | | | | 5B) THE RECEPTION AREA SHOULD READ RECEPTION & | | | CONFERENCE ROOM, THE SQUARE FOOTAGE OF 1,038/ 15= 95 | | | WHEN ROUNDED UP. PLEASE UPDATE PLANS, 2017 FBC-B TABLE | | | 1004.1.2. | | | | | | 5C) THE OTHER ISSUE WITH THE RECEPTION/ CONFERENCE ROOM | | | OCCUPANT LOAD IS THE COMMON PATH OF TRAVEL. | | | SEE TABLE 1006.2.1 THE MAXIMUM OCCUPANT LOAD OF 30 | | | OCCUPANTS IN THE ASSEMBLY OCCUPANCY THE COMMON PATH OF | | | TRAVEL IS LIMITED TO 75 FEET AND THE MAXIMUM OCCUPANT | | | LOAD OF 49, TABLE 1006.1.2. | | | | | | PLEASE REVIEW SECTION 1006.2.1 EGRESS BASED ON OCCUPANT | | | LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO | | | EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE | | | PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON | | | PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES | | | LISTED IN TABLE 1006.2.1. THE EXCEPTION FORI-2 DOES NOT | | | WORK SINCE THIS IS NOT A CARE SUITE WITHIN A HOSPITAL. | | | PLEASE PROVIDE 2 EXIT ACCESS DOORWAY THAT WILL BE IN | | | COMPLIANCE WITH FBC-B 1007.1.1 EXCEPTION2. | | | FBC-B 1007.1.1 EXCEPTION2. WHERE A BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE | | | SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF | | | THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF | | | THE AREA SERVED. | | | | | | THERE ARE 2 AREAS OF CONCERN, 1ST IN THE CONFERENCE | | | ROOM ITSELF REQUIRING 2 MEANS OF EGRESS, OUTSWING DOOR | | | REQUIRED. THE 2ND AREA IS WITHIN THE TENANT SPACE | | | ITSELF THE TOTAL OCCUPANT LOAD IS OVER 49 REQUIRING | | | ALSO 2 MEANS OF EGRESS. | | | | | | 6) SHEET A6.0 ACCESSIBLE FEATURES: | | | | | | 6A) THE PLAN SHOWS AN ACCESSIBLE RESTROOM & BATHROOM | | | WITHIN THE RESTROOM & BATHROOM THE PLAN FAILS TO SHOW | | | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY SECTION | | | 604.3.1 CLEARANCE/ SIZE. 604.3.1 SIZE. CLEARANCE AROUND | | | A WATER CLOSET SHALL BE 60 INCHES (1525 MM) MINIMUM | | | MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES | | | (1420 MM) MINIMUM MEASURED PERPENDICULAR FROM THE REAR | | | WALL. | | | | | | 604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND THE | | | WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER | | | CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY | | | NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE | | | ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT | | | OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER | | | FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE | | | REQUIRED WATER CLOSET CLEARANCE. | | | | | | 6B) THE PLAN ALSO SHOWS WHAT APPEARS TO BE AN | | | ACCESSIBLE BATHROOM EQUIPPED WITH A WALK-IN SHOWER. | | | PLEASE NOTE THIS BATHROOM HAS TO MEET ALL OF THE | | | REQUIREMENTS FOR AN ACCESSIBLE RESTROOM, IT DOES NOT | | | MEET THE REQUIREMENT FOR A PRIVATE BATHROOM. | | | FBC-ACCESS. CODE 603.2.3 EXCEPT. 1 DOORS TO A TOILET | | | ROOM OR BATHING ROOM FOR A SINGLE OCCUPANT ACCESSED | | | ONLY THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE OR | | | PUBLIC USE SHALL BE PERMITTED TO SWING INTO THE CLEAR | | | FLOOR SPACE OR CLEARANCE PROVIDED THE SWING OF THE DOOR | | | CAN BE REVERSED TO COMPLY WITH 603.2.3. | | | | | | 6C) THE BATHROOM SHOWS A SHOWER BUT DOES NOT SHOW ANY | | | DETAILS OF GRAB BARS, BACKING, OR THE WALL OF WHICH | | | WHERE THE CONTROLS ARE INSTALLED, CLEAR FLOOR SPACE, | | | NOTHING. 609.4, 608.5.2, & 608.2.2. | | | | | | 6D) THE BATHROOM ALSO SHOWS THE INSWING DOOR SWINGING | | | INTO THE REQUIRED CLEAR FLOOR SPACE FOR THE WATER | | | CLOSET AND SHOWER. PLEASE NOTE NEITHER THE CLEAR FLOOR | | | SPACE FOR THE SHOWER AND WATER CLOSET IS SHOWN. | | | 107.2.1.2 ADDITIONAL INFORMATION REQUIRED. 604.3.1 & | | | 604.3.2 OVERLAP. | | | | | | 6E) PLEASE REVIEW DETAIL # 6 SINKS FOR HEIGHT | | | REQUIREMENTS. THIS DETAIL SHOWS THE HEIGHT OF 2 FOOT 10 | | | INCHES TAKEN FROM THE FLOOR TO THE COUNTER TOP. THE | | | CODE READS LAVATORIES AND SINKS SHALL BE INSTALLED WITH | | | THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE | | | 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. THE HIGHER OF THE 2 SURFACES, DEPENDING ON THE | | | FLANGE HEIGHT OF THE SINK YOU MAYBE OVER CONSTRUCTION | | | TOLERANCES. 606 LAVATORIES AND SINKS> 2017 | | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | | | | 7) SHEET A7.0 DETAIL C IS TAKEN IN THE CONFERENCE ROOM | | | BREAK AREA SINK. THE HEIGHT OF THE CABINET COUNTERTOP | | | IS 36 INCHES FROM THE FLOOR PLUS THE THICKNESS OF THE | | | SINK RIM. PLEASE SHOW COMPLIANCE WITH: | | | | | | 2017 FBC-ACCESS. CODE SECTION 606 LAVATORIES AND SINKS> | | | 2017 FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-15 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-15 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-14 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-14 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-05-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-27 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-27 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2019-05-27 10:27:39 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS, 3RD REVIEW: DENIED, SEE | | | COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. ALL RECEPTACLES WITHIN SIX FEET OF A SINK REQUIRE | | | GFCI PROTECTION. PROVIDE CORRECTION FOR EXAM ROOMS. NEC | | | 210.8 (NO RESPONSE RECEIVED, NOT CORRECTED.) | | | 2. PLEASE INDICATE ON PLANS WHICH ROOMS SHALL BE WIRED | | | PER NEC 517.13 (NO RESPONSE RECEIVED, NOT CORRECTED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-20 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2019-05-20 14:11:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. ALL RECEPTACLES WITHIN SIX FEET OF A SINK REQUIRE | | | GFCI PROTECTION. PROVIDE CORRECTION FOR EXAM ROOMS. NEC | | | 210.8 (NO RESPONSE RECEIVED, NOT CORRECTED.) | | | 2. PLEASE INDICATE ON PLANS WHICH ROOMS SHALL BE WIRED | | | PER NEC 517.13 (NO RESPONSE RECEIVED, NOT CORRECTED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-04 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-03 |
Time |
12:15 |
Sent To |
I |
|
| Notes |
| 2019-04-04 12:59:23 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ALL RECEPTACLES WITHIN SIX FEET OF A SINK REQUIRE | | | GFCI PROTECTION. PROVIDE CORRECTION FOR EXAM ROOMS. NEC | | | 210.8 | | | 2. PLEASE INDICATE ON PLANS WHICH ROOMS SHALL BE WIRED | | | PER NEC 517.13 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2019-08-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-08-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-08-01 |
Time |
14:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-07-15 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-05-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-23 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-05-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-05-16 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-25 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-25 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-08-05 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-30 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2019-07-31 13:56:57 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-07-29 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-07-11 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-06-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-17 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-06-07 |
Time |
10:12 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-06-03 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-21 |
Time |
14:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-05-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-30 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-19 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2019-03-27 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2019-03-26 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-07-15 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-07-15 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-31 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-31 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-25 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-25 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-07-19 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-07-19 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-06-13 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-06-13 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-06-11 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2019-06-13 15:20:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | NFPA 30A | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 4TH REVIEW; CONDUCTED BY JERALD SMITH; PHONE | | | 561-805-6715 | | | PLUMBING COMMEMTS: DENIED | | | NOTE | | | * PER FL ST 553.80 (B)2B WITH RESPECT TO EVALUATION OF | | | DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT | | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW.*** | | | * ARCHITECTURAL COMMENTS AND RESPONSES ATTACHED TO | | | PLANS SEEM TO BE DIRECTED AT THE SECOND PLUMBING REVIEW | | | DATED 5/6/19 AND NOT THE LATEST REVIEW DATED 5/28/19. | | | ADDITIONALLY, REVISION DATES, SPECIFICALLY ON PLAN | | | SHEET A6.0 DO NOT ADDRESS THE THIRD REVIEW DATED | | | 5/28/19. | | | * DO NOT RESUBMIT WITHOUT FIRST HOLDING A SCHEDULED | | | MEETING WITH THE PLANS EXAMINER(S) TO RESOLVE THE | | | ISSUES. PLEASE CONTACT SAMANTHA HILL AT 805-6724 FOR | | | SCHEDULING. | | | PLEASE NOTE THAT PLUMBING WILL NOT BE APPROVED UNTIL | | | THE ISSUES ON THE ARCHITECTURAL PLANS HAVE BEEN | | | CORRECTLY ADDRESSED | | | 1. 4TH REQUEST- ARCHITECTURAL ISSUE: PLAN SHEET A6.0; | | | THE LOCATION OF THE REAR GRAB BAR SHALL COMPLY WITH | | | FBC-ACCESS. SEC.604.5.2. 24" OPPOSITE THE 12" NOT SHOWN | | | ON DETAIL (GRAB BAR AT WATER CLOSET) SHT. A6.0. TO | | | CLARIFY THE DETAIL, DIMENSION FROM CENTER OF WATER | | | CLOSET TO LEFT SHALL BE 24? MIN., NOT 12?. | | | ADDITIONALLY, THE DETAIL NOW DOES NOT COMPLY WITH FBC | | | ACC 604.2, REQUIRING A SIDE WALL WITH THE CENTERLINE | | | WATER CLOSET DIMENSION BEING 16?-18?. SEE FIGURE 604.2 | | | FOR CLARITY. | | | 2. 4TH REQUEST-PLAN SHEET P-2: PLUMBING GENERAL NOTE #1 | | | REFERS TO THE 2014 FBC. THE CODE IN EFFECT IS THE 2017 | | | FBC. REVISE AND RESUBMIT. NOT ADDRESSED | | | 3. 4TH REQUEST-PER WPB FBC 107.2.1, SUBMIT | | | MANUFACTURER'S SPECIFICATIONS FOR THE TANKLESS WATER | | | HEATERS. NOT ADDRESSED, WILL ALLOW DEFERRED SUBMITTAL | | | 4. 2ND REQUEST- ARCHITECTURAL ISSUE: THIS IS APPROVED | | | SHT. A6.0 DETAIL #9 SHOWS GRAB BARS MEASURED TO THE | | | ESCUTCHEON RING; THE DETAIL FOR THE GRAB BARS AT WATER | | | CLOSET SHOWS MEASURED TO THE CENTER OF THE GRAB BAR, | | | THEY BOTH SHALL SHOW MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE. FBC ACC 609.4. PLEASE NOTE THAT | | | DETAIL #7 BATHROOM BACKING DETAIL CORRECTLY SHOWS THE | | | REQUIREMENTS. RECONCILE DETAIL #9 WITH #7. | | | 5. REGARDING THE FOLLOWING COMMENTS MADE DURING THE | | | SECOND REVIEW CONCERNING THE SHOWER IN THE TOILET RM W/ | | | SHOWER STAFF RM #110, PLEASE NOTE: | | | A. ARCHITECTURAL ISSUE: SHT. A6.0 DETAIL #5 THE | | | ACCESSIBLE SHOWER DETAIL DOES NOT MATCH DETAIL #1 | | | ENLARGED BATHROOM THE SHOWER SHALL COMPLY WITH FBC ACC | | | 608.2.2.1, 608.3.2, 608.5.2. NOTE THAT THE SPACE AND | | | CONFIGURATION ALLOWED BY THE ARCHITECT DOES NOT MEET | | | THE REQUIREMENTS FOR A STANDARD ROLL IN SHOWER | | | COMPARTMENT. | | | B. ARCHITECTURAL ISSUE: THE SEAT IS BEING SHOWN ON THE | | | SAME SIDE AS THE END GRAB BAR IT SHALL BE ON THE | | | OPPOSITE END IT WILL BE DIFFICULT TO COMPLY WITH THE | | | ANGLE WALL. FBC ACC 608.3.2. THE ARCHITECT HAS MOVED | | | THE SEAT TO THE OPPOSITE SIDE OF THE SHOWER STALL ON | | | A6.0, DETAIL 1. ADDITIONALLY, HE HAS MADE THE STALL 36? | | | WIDE AND OFFSET THE SEAT TO THE CURB SIDE OF THE SHOWER | | | (DUE TO AN OBSTRUCTION LESS THAN 10?) AS OPPOSED TO | | | BEING WITHIN 30? MINIMUM WIDTH SPACE, INCREASING THE | | | SIDE REACH SPACE BETWEEN THE USER AND GRAB BARS BY 6?. | | | PLEASE REVIEW FBC ACC 308.3, 308.3.1, (1), (2), | | | 308.3.2, (1), (2) AND 309 FOR COMPLIANCE AND NOTE | | | ACTUAL OBSTRUCTION DIMENSION (I.E. 6? OBSTRUCTION DUE | | | TO ANGLE WALL) IF APPLICABLE ON PLAN SHEET A6.0, DETAIL | | | 1. | | | C. ARCHITECTURAL ISSUE: THE ENDS OF THE GRAB BARS SHALL | | | BE 6" MAX FROM ADJACENT WALL. FBC ACC 608.3.2. THIS IS | | | APPROVED | | | D. ARCHITECTURAL ISSUE: SHOW CLEAR FLOW SPACE FOR | | | SHOWER. FBC ACC 608.2.2.1. NOT ADDRESSED | | | 6. ADDITIONAL COMMENTS (3D REVIEW) CONCERNING TOILET RM | | | W/ SHOWER STAFF RM #110: | | | A. ARCHITECTURAL ISSUE: FBC ACC 604.2 REQUIRES THAT THE | | | WATER CLOSET POSITIONED WITH A WALL OR PARTITION TO THE | | | REAR AND ONE SIDE OF THE FIXTURE; SIDE AND REAR HAND | | | BARS SHALL CONFORM TO FBC ACC 604.5.1 AND 605.2. A | | | PULLDOWN GRAB BAR IS NOT COMPLIANT AND SHALL NOT BE | | | USED. TO BE CLEAR, THIS COMMENT WAS DIRECTED AT THE | | | TOILET ROOM WITH SHOWER AND HAS NOT BEEN ADDRESSED. | | | FURTHERMORE, AS A PULLDOWN GRAB BAR IS NOT COMPLIANT, | | | PLEASE REMOVE DETAIL 10 FROM PLAN SHEET A6.0. | | | B. ARCHITECTURAL ISSUE: FBC ACC 604.7 REQUIRES TOILET | | | PAPER DISPENSER TO BE LOCATED ON THE SIDE WALL 7?-9? | | | FRONT OF THE WATER CLOSET TO CENTER OF DISPENSER AND | | | INSIDE THE SPACE OF 15? MINIMUM TO 48?? MAXIMUM ABOVE | | | THE FLOOR. TO BE CLEAR, THIS COMMENT WAS DIRECTED AT | | | THE TOILET ROOM WITH SHOWER AND HAS NOT BEEN ADDRESSED. | | | C. ARCHITECTURAL ISSUE: NOTE THAT PER 604.8.1.2, THE | | | ENTRY DOOR SHALL BE LOCATED IN THE FRONT PARTITION OR | | | IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER | | | CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR | | | OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE | | | SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. | | | WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR | | | OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE | | | FRONT PARTITION. TO BE CLEAR, THIS COMMENT WAS DIRECTED | | | AT THE TOILET ROOM WITH SHOWER AND HAS NOT BEEN | | | ADDRESSED. | | | | | | 7. 3RD REVIEW ADDITIONAL COMMENTS | | | A. PLAN SHEET P-1 AND P-3; MOP SINK LOCATION. RECONCILE | | | SANITARY ISOMETRIC ON P-3 WITH THE FLOOR PLAN ON P-1. | | | NOT ADDRESSED | | | B. REGARDING THE FOLLOWING ORIGINAL COMMENT: TEMPERED | | | WATER IS REQUIRED AT THE LAVATORIES IN THE TOILET ROOMS | | | AND BATHROOM PER FBC-PLUMBING. SEC. 416.5. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. PER WPB FBC 107.2.1, PROVIDE CUT | | | SHEET AND SPEC FOR OWNER FURNISHED WALL MOUNTED, ADA | | | COMPLIANT ANTI-SCALD VALVE SHOWING COMPLIANCE WITH ASSE | | | 1070 OR CSA B125.3 AS REQUIRED BY FBC PL 416.5 FOR THE | | | HANDICAPPED LAVATORIES. ALSO PROVIDE A DETAIL OF | | | INSTALLATION TO SHOW COMPLIANCE WITH FBC ACC 309. NOT | | | ADDRESSED, WILL ALLOW DEFERRED SUBMITTAL | | | 4TH REVIEW ADDITIONAL COMMENTS | | | 1. RE: PLAN SHEET A6.0, ACCESSIBLE DETAIL 5; THRESHOLD | | | SHALL BE A MAXIMUM OF ?? PER FBC ACC 608.7 AND GRAB | | | BARS SHALL BE 33? MINIMUM-36? MAXIMUM TO TOP SURFACE OF | | | GRAB BAR. | | | 2. RE: PLAN SHEET A7.0, DETAIL C; DIMENSION 2?-10? | | | MAXIMUM TO RIM OF FIXTURE NOT TO TOP OF CABINET AS RIM | | | IS HIGHER THAN THE CABINET TOP PER FBC ACC 606.3. | | | 3. RE: PLAN SHEET A6.0, ACCESSIBLE WATER FOUNTAIN | | | DETAIL; PROVIDE KNEE AND TOE CLEARANCES CONFORMING TO | | | FBC ACC 306.2 AND 306.3 AND CONFORM TO FBC ACC 602.4 | | | AND 602.5. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19030897 1411 N FLAGLER DR # 8900 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-05-28 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-05-28 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2019-05-28 14:32:23 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | 3RD REVIEW | | | PLUMBING COMMEMTS: DENIED | | | PLEASE NOTE THAT PLUMBING WILL NOT BE APPROVED UNTIL | | | THE ISSUES ON THE ARCHITECTURAL PLANS HAVE BEEN | | | CORRECTLY ADDRESSED | | | | | | 1. 3RD REQUEST- ARCHITECTURAL ISSUE: PLAN SHEET A6.0; | | | THE LOCATION OF THE REAR GRAB BAR SHALL COMPLY WITH | | | FBC-ACCESS. SEC.604.5.2. 24" OPPOSITE THE 12" NOT SHOWN | | | ON DETAIL (GRAB BAR AT WATER CLOSET) SHT. A6.0. TO | | | CLARIFY THE DETAIL, DIMENSION FROM CENTER OF WATER | | | CLOSET TO LEFT SHALL BE 24? MIN., NOT 12?. | | | | | | 2. 3RD REQUEST-PLAN SHEET P-2: PLUMBING GENERAL NOTE #1 | | | REFERS TO THE 2014 FBC. THE CODE IN EFFECT IS THE 2017 | | | FBC. REVISE AND RESUBMIT. | | | | | | 3. 3RD REQUEST-PER WPB FBC 107.2.1, SUBMIT | | | MANUFACTURER'S SPECIFICATIONS FOR THE TANKLESS WATER | | | HEATERS. | | | | | | 4. 2ND REQUEST- ARCHITECTURAL ISSUE: SHT. A6.0 DETAIL | | | #9 SHOWS GRAB BARS MEASURED TO THE ESCUTCHEON RING; THE | | | DETAIL FOR THE GRAB BARS AT WATER CLOSET SHOWS MEASURED | | | TO THE CENTER OF THE GRAB BAR, THEY BOTH SHALL SHOW | | | MEASURED TO THE TOP OF THE GRIPPING SURFACE. FBC ACC | | | 609.4. PLEASE NOTE THAT DETAIL #7 BATHROOM BACKING | | | DETAIL CORRECTLY SHOWS THE REQUIREMENTS. RECONCILE | | | DETAIL #9 WITH #7. | | | | | | 5. REGARDING THE FOLLOWING COMMENTS MADE DURING THE | | | SECOND REVIEW CONCERNING THE SHOWER IN THE TOILET RM W/ | | | SHOWER STAFF RM #110, PLEASE NOTE: | | | A. ARCHITECTURAL ISSUE: SHT. A6.0 DETAIL #5 THE | | | ACCESSIBLE SHOWER DETAIL DOES NOT MATCH DETAIL #1 | | | ENLARGED BATHROOM THE SHOWER SHALL COMPLY WITH FBC ACC | | | 608.2.2.1, 608.3.2 , 608.5.2. NOTE THAT THE SPACE AND | | | CONFIGURATION ALLOWED BY THE ARCHITECT DOES NOT MEET | | | THE REQUIREMENTS FOR A STANDARD ROLL IN SHOWER | | | COMPARTMENT. | | | B. ARCHITECTURAL ISSUE: THE SEAT IS BEING SHOWN ON THE | | | SAME SIDE AS THE END GRAB BAR IT SHALL BE ON THE | | | OPPOSITE END IT WILL BE DIFFICULT TO COMPLY WITH THE | | | ANGLE WALL. FBC ACC 608.3.2 | | | C. ARCHITECTURAL ISSUE: THE ENDS OF THE GRAB BARS SHALL | | | BE 6" MAX FROM ADJACENT WALL. FBC ACC 608.3.2 | | | D. ARCHITECTURAL ISSUE: SHOW CLEAR FLOW SPACE FOR | | | SHOWER. FBC ACC 608.2.2.1 | | | | | | 6. ADDITIONAL COMMENTS CONCERNING TOILET RM W/ SHOWER | | | STAFF RM #110: | | | A. ARCHITECTURAL ISSUE: FBC ACC 604.2 REQUIRES THAT THE | | | WATER CLOSET POSITIONED WITH A WALL OR PARTITION TO THE | | | REAR AND ONE SIDE OF THE FIXTURE; SIDE AND REAR HAND | | | BARS SHALL CONFORM TO FBC ACC 604.5.1 AND 605.2. A | | | PULLDOWN GRAB BAR IS NOT COMPLIANT AND SHALL NOT BE | | | USED. | | | B. ARCHITECTURAL ISSUE: FBC ACC 604.7 REQUIRES TOILET | | | PAPER DISPENSER TO BE LOCATED ON THE SIDE WALL 7?-9? | | | FRONT OF THE WATER CLOSET TO CENTER OF DISPENSER AND | | | INSIDE THE SPACE OF 15? MINIMUM TO 48? MAXIMUM ABOVE | | | THE FLOOR. | | | C. ARCHITECTURAL ISSUE: NOTE THAT PER 604.8.1.2, THE | | | ENTRY DOOR SHALL BE LOCATED IN THE FRONT PARTITION OR | | | IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER | | | CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR | | | OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE | | | SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. | | | WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR | | | OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE | | | FRONT PARTITION. | | | | | | 7. NEW COMMENTS | | | A. PLAN SHEET P-1 AND P-3; MOP SINK LOCATION. RECONCILE | | | SANITARY ISOMETRIC ON P-3 WITH THE FLOOR PLAN ON P-1. | | | B. REGARDING THE FOLLOWING ORIGINAL COMMENT: ?TEMPERED | | | WATER IS REQUIRED AT THE LAVATORIES IN THE TOILET ROOMS | | | AND BATHROOM PER FBC-PLUMBING. SEC. 416.5. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3.? PER WPB FBC 107.2.1, PROVIDE CUT | | | SHEET AND SPEC FOR OWNER FURNISHED WALL MOUNTED, ADA | | | COMPLIANT ANTI-SCALD VALVE SHOWING COMPLIANCE WITH ASSE | | | 1070 OR CSA B125.3 AS REQUIRED BY FBC PL 416.5 FOR THE | | | HANDICAPPED LAVATORIES. ALSO PROVIDE A DETAIL OF | | | INSTALLATION TO SHOW COMPLIANCE WITH FBC ACC 309. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 19030897 1411 N FLAGLER DR # 8900 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-05-06 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-05-02 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2019-05-06 15:25:53 | | | | 2ND REVIEW: 19030897 | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PREVIOUS COMMENTS NOT COMPLIED IT APPEARS THAT PLUMBING | | | PAGES WERE NOT REVISED THE RESPONSE LETTER REFERRED TO | | | MEP LETTER IT WAS NOT IN PERMIT DOCUMENT PACKAGE. | | | | | | 10) THE LOCATION OF THE REAR GRAB BAR SHALL COMPLY WITH | | | FBC-ACCESS. SEC.604.5.2. 24" OPPOSITE THE 12" NOT SHOWN | | | ON DETAIL SHT. A6.0 | | | 13) SHT. A7.1 - THE MAXIMUM HEIGHT OF THE KITCHEN | | | CABINETS ( DETAIL "D") SHALL BE 34 INCHES ABOVE THE | | | FINISH FLOOR. FBC-ACCESS. SEC. 606.3. | | | 14) A MOP SINK IS REQUIRED PER 2017 FBC-PLUMBING TABLE | | | 403.1. NOT SHOWN ON PLUMBING PLAN. | | | 15) THE SINK IN EXAM ROOM #1 IS NOT SHOWN ON THE | | | SANITARY OR WATER RISER DIAGRAM. CLARIFY. | | | 16) SHOW THE LOCATION OF THE DRINKING FOUNTAINS ON SHT. | | | A2.0. DRINKING FOUNTAINS SHALL COMPLY WITH FBC-ACCESS. | | | SEC.307 FOR PROTRUDING OBJECTS. | | | 17) THE LAYOUT OF EXAM ROOM #7 ON SHT. A2.0 DOES NOT | | | CORRELATE WITH THE LAYOUT ON SHT. P-1. CLARIFY. | | | 18) TEMPERED WATER IS REQUIRED AT THE LAVATORIES IN THE | | | TOILET ROOMS AND BATHROOM PER FBC-PLUMBING. SEC. | | | 416.5.TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | 19) SHT. P-2, GENERAL NOTE #1 REFERS TO THE 2014 FBC. | | | THE CODE IN EFFECT IS THE 2017 FBC. | | | 20) SHT. P-2 - PLUMBING FIXTURE CONNECTION SCHEDULE - | | | NOTE #2 REFERS TO ORDINANCE 8.31 OF MIAMI DADE COUNTY. | | | REMOVE THIS NOTE FROM THE PLAN. NOTE #3 REFERS TO THE | | | RESIDENTIAL PLUMBING CODE. REMOVE THIS NOTE FROM THE | | | PLANS. | | | 21) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | TANKLESS WATER HEATERS. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | NEW COMMENTS: | | | | | | 1. SHT. A6.0 DETAIL #5 THE ACCESSIBLE SHOWER DETAIL | | | DOES NOT MATCH DETAIL #1 ENLARGED BATHROOM THE SHOWER | | | SHALL COMPLY WITH FBC ACC 608.2.2.1, 608.3.2 , 608.5.2 | | | THE SEAT IS BEING SHOWN ON THE SAME SIDE AS THE END | | | GRAB BAR IT SHALL BE ON THE APOSTATE END IT WILL BE | | | DIFFICULT TO COMPLY WITH THE ANGLE WALL. FBC ACC | | | 608.3.2 | | | THE ENDS OF THE GRAB BARS SHALL BE 6" MAX FROM ADJACENT | | | WALL. FBC ACC 608.3.2 | | | SHOW CLEAR FLOW SPACE FOR SHOWER.FBC ACC 608.2.2.1 | | | | | | 2. SHT. A6.0 DETAIL #9 SHOWS GRAB BARS MEASURED TO THE | | | THE ESCUTCHEON RING THE DETAIL FOR THE GRAB BARS AT | | | WATER CLOSET SHOWS MEASURED TO THE CENTER OF THE GRAB | | | BAR, THEY BOTH SHALL SHOW MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE. FBC ACC 609.4 | | | | | | 3. A6.0 PROVIDE DETAIL FOR PULL DOWN GRAB BAR AND SHOW | | | ON SHOW ON ACCESSORY SCHEDULE. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4. MOP SINK AND WATER FOUNTAIN ARE NOT SHOWN ON THE | | | PLUMBING PAGES THEY ARE SHOWN ARCHITECTURAL PAGES | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. THE FLOOR PLAN ON SHT A2.0 IS SHOWING A CORRIDOR | | | ALONG SIDE BATHROOM 110 A CLOSET 103 THIS IS NOT SHOWN | | | ON THE MEP PAGES AT THE END OF THE CORRIDOR IS THE | | | REQUIRED WATER FOUNTAIN. PLEASE CLARIFY. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-04-03 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-04-03 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2019-04-03 08:46:25 | 1) SHEET A2.0 HAS (2) NOTES THAT DEAL WITH THE | | | RESIDENTIAL CODE FBC-R 308. PLEASE REMOVE ALL NOTES | | | DEALING WITH THE ONE & TWO FAMILY RESIDENTIAL CODE. | | | 107.2.1 | | | 2) SHEET A2.0 HAS NOTES REFERRING TO THE FLORIDA | | | ACCESSIBILITY CODE AND THE ADA. THE CODE SECTIONS NOTED | | | ARE NOT IN THE FLORIDA ACCESSIBILITY CODE. THE HANDICAP | | | CODE IN EFFECT IN FLORIDA IS THE FLORIDA ACCESSIBILITY | | | CODE, NOT THE ADA. DELETE THESE CODE SECTIONS AND | | | REFERENCE TO THE ADA FROM THE PLANS. | | | 3) ONE OF THE EXAM ROOM SINKS SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE 2017 FBC-ACCESS. SEC.212.3, SEC. | | | 606. THE MAXIMUM HEIGHT OF THE FROM THE FINISH FLOOR TO | | | THE SINK SHALL BE 34 INCHES. A CLEAR FLOOR SPACE | | | COMPLYING WITH 2017 FBC-ACCESS. SEC. 305, POSITIONED | | | FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH306 SHALL BE PROVIDED. FAUCETS SHALL | | | COMPLY WITH SEC. 309. EXPOSED PIPE AND SURFACES SHALL | | | COMPLY WITH SEC. 606.5. | | | 4) SHT. A2.0 & A6.0 - SHOW THE CLEAR FLOOR SPACE FOR | | | THE LAVATORY AND THE WATER CLOSET IN ALL OF THE TOILET | | | ROOMS AND ALSO FOR THE SHOWER.2017 FBC - ACCESS. | | | SECS.604.3.1, 606.2, 608.2.2.1. | | | 4A) THE PLAN SHOWS AN ACCESSIBLE RESTROOM & BATHROOM | | | WITHIN THE RESTROOM & BATHROOM THE PLAN FAILS TO SHOW | | | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY SECTION | | | 604.3.1 CLEARANCE/ SIZE. 604.3.1 SIZE. CLEARANCE AROUND | | | A WATER CLOSET SHALL BE 60 INCHES (1525 MM) MINIMUM | | | MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES | | | (1420 MM) MINIMUM MEASURED PERPENDICULAR FROM THE REAR | | | WALL. | | | 4B) THE PLAN ALSO SHOWS WHAT APPEARS TO BE AN | | | ACCESSIBLE BATHROOM EQUIPPED WITH A ROLL-IN SHOWER. | | | PLEASE NOTE THIS BATHROOM HAS TO MEET ALL OF THE | | | REQUIREMENTS FOR AN ACCESSIBLE RESTROOM, IT DOES NOT | | | MEET THE REQUIREMENT FOR A PRIVATE BATHROOM. | | | 4C)THE DOOR FOR THE BATHROOM WITH THE SHOWER SWINGS | | | INTO THE CLEAR FLOOR SPACE FOR THE WATER CLOSET AND | | | SHOWER.DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE | | | REQUIRED FOR ANY FIXTURE PER 2017 FBC-ACCESS SEC. | | | 603.2.3. | | | 4D) THE BATHROOM SHOWS A SHOWER BUT DOES NOT SHOW ANY | | | DETAILS OF GRAB BARS, BACKING, OR THE WALL OF WHICH | | | WHERE THE CONTROLS ARE INSTALLED, CLEAR FLOOR SPACE, | | | NOTHING. 609.4, 608.5.2, & 608.2.2. | | | 5) SHOW THE SHOWER WIDTH DIMENSIONS ON SHT. A6.0. | | | COMPLY WITH 2017 FBC - ACCESS. SEC.608.2.2. | | | 6) PLEASE REVIEW DETAIL # 6 SINKS FOR HEIGHT | | | REQUIREMENTS. THIS DETAIL SHOWS THE HEIGHT OF 2 FOOT 10 | | | INCHES TAKEN FROM THE FLOOR TO THE COUNTER TOP. THE | | | CODE READS LAVATORIES AND SINKS SHALL BE INSTALLED WITH | | | THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE | | | 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. THE HIGHER OF THE 2 SURFACES, DEPENDING ON THE | | | FLANGE HEIGHT OF THE SINK YOU MAY BE OVER CONSTRUCTION | | | TOLERANCES. 606 LAVATORIES AND SINKS> 2017 | | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | 7) SHEET A7.0 DETAIL C IS TAKEN IN THE CONFERENCE ROOM | | | BREAK AREA SINK. THE HEIGHT OF THE CABINET COUNTERTOP | | | IS 36 INCHES FROM THE FLOOR PLUS THE THICKNESS OF THE | | | SINK RIM. THE MAXIMUM HEIGHT SHALL BE 34 INCHES. 2017 | | | FBC-ACCESS. SEC.606.3. | | | 8) SHT. A6.0 - THE TOILET PAPER DISPENSER SHALL BE | | | LOCATED A MINIMUM OF 7 INCHES AND A MAXIMUM OF 9 INCHES | | | TO THE CENTER OF THE DISPENSER FROM THE FRONT OF THE | | | TOILET BOWL. FBC-ACCESS. SEC.604.7. | | | 9) THE GRAB BARS SHALL BE MOUNTED 33 INCHES MINIMUM AND | | | 36 MAXIMUM FROM THE FINISH FLOOR TO THE TOP OF THE | | | GRIPPING SURFACE. FBC-ACCESS. SEC.609.4. | | | 10) THE LOCATION OF THE REAR GRAB BAR SHALL COMPLY WITH | | | FBC-ACCESS. SEC.604.5.2. | | | 11) SHT. A6.0 - RESTROOM FLOOR PLAN - CHECK THE TOILET | | | ACCESSORY ITEM SCHEDULE LOCATION . THE FLOOR PLAN SHOWS | | | ITEM J IN THE MIDDLE OF THE DOORWAY, ITEM H AS A SOAP | | | DISPENSER, ITEM G AS A TOILET PAPER DISPENSER AND SHOWN | | | AT THE LAVATORY, ITEM C IS CALLED OUT AS A GRAB BAR AND | | | SHOWN AT THE LAVATORY, ITEM E IS SHOWN AS A GRAB BAR | | | BUT LISTED AS A PAPER TOWEL DISPENSER, AND THE LAVATORY | | | IS CALLED OUT AS "NON-ADA.." CLARIFY.THE LAVATORY IS | | | REQUIRED TO COMPLY WITH THE FLORIDA ACCESS. CODE. | | | 12) SHT. A6.0 - ACCESSIBILITY NOTE #5 - THE HEIGHT OF | | | THE WATER CLOSET TO THE TOP OF THE SEAT SHALL BE 17 | | | INCHES MINIMUM AND 19 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR.FBC-ACCESS. SEC.604.4. | | | 13) SHT. A7.1 - THE MAXIMUM HEIGHT OF THE KITCHEN | | | CABINETS ( DETAIL "D") SHALL BE 34 INCHES ABOVE THE | | | FINISH FLOOR. FBC-ACCESS. SEC. 606.3. | | | 14) A MOP SINK IS REQUIRED PER 2017 FBC-PLUMBING TABLE | | | 403.1. | | | 15) THE SINK IN EXAM ROOM #1 IS NOT SHOWN ON THE | | | SANITARY OR WATER RISER DIAGRAM. CLARIFY. | | | 16) SHOW THE LOCATION OF THE DRINKING FOUNTAINS ON SHT. | | | A2.0. DRINKING FOUNTAINS SHALL COMPLY WITH FBC-ACCESS. | | | SEC.307 FOR PROTRUDING OBJECTS. | | | 17) THE LAYOUT OF EXAM ROOM #7 ON SHT. A2.0 DOES NOT | | | CORRELATE WITH THE LAYOUT ON SHT. P-1. CLARIFY. | | | 18) TEMPERED WATER IS REQUIRED AT THE LAVATORIES IN THE | | | TOILET ROOMS AND BATHROOM PER FBC-PLUMBING. SEC. | | | 416.5.TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. | | | 19) SHT. P-2, GENERAL NOTE #1 REFERS TO THE 2014 FBC. | | | THE CODE IN EFFECT IS THE 2017 FBC. | | | 20) SHT. P-2 - PLUMBING FIXTURE CONNECTION SCHEDULE - | | | NOTE #2 REFERS TO ORDINANCE 8.31 OF MIAMI DADE COUNTY. | | | REMOVE THIS NOTE FROM THE PLAN. NOTE #3 REFERS TO THE | | | RESIDENTIAL PLUMBING CODE. REMOVE THIS NOTE FROM THE | | | PLANS. | | | 21) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | TANKLESS WATER HEATERS. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-07-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-07-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-07-17 16:14:47 | INTERIOR MODIFICATIONS ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-25 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2019-03-25 16:52:42 | INTERIOR MODIFICATIONS ONLY. | | | | | | | | | NOTE: | | | | | | * Z = CSPD |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |