Plan Review Details - Permit 19030673
Plan Review Stops For Permit 19030673
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-09-30 Cont ID  
Sent By jwitmer Date 2019-09-30 Time 15:22 Rev Time 0.00
Received By jwitmer Date 2019-09-30 Time 11:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-06-05 Cont ID  
Sent By jwitmer Date 2019-06-05 Time 09:05 Rev Time 0.00
Received By jwitmer Date 2019-06-05 Time 07:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-10-03 Cont ID  
Sent By jpearson Date 2019-10-03 Time 08:24 Rev Time 0.00
Received By jpearson Date 2019-10-03 Time 08:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-06-12 Cont ID  
Sent By jpearson Date 2019-06-12 Time 15:45 Rev Time 0.00
Received By jpearson Date 2019-06-12 Time 12:27 Sent To  
Notes
2019-06-12 12:47:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SHEET E01.01, PLAN STATES THAT PUBLIX IS SUPPLYING
 THE LIGHT FIXTURES. IN REFERENCE TO VALUE OF THE STATED
 WORK, ALL MATERIALS AND LABOR SHOULD BE INCLUDED IN THE
 STATED VALUE. UNDER THIS PERMIT, THE VALUES FOR
 BUILDING, MECHANICAL, ELECTRICAL, AND PLUMBING SHOULD
 BE INCLUDED. REMOVE ANY VALUES FOR SYSTEMS THAT REQUIRE
 A SEPARATE PERMIT, AS THOSE VALUES WILL BE REQUIRED
 WHEN PERMIT APPLICATION IS MADE FOR THOSE SEPARATE
 PERMITS. SEE NOTE 2 BELOW. PROVIDE COPY OF SIGNED
 CONTRACT WITH SCOPE AND VALUE OF WORK, TO INCLUDE ALL
 MATERIALS AND LABOR. THIS IS FOR TOTAL PROJECT, NOT
 JUST ELECTRICAL. WPB FBC 109.3
 2. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC
 105.1, 107.2.1
 3. LOAD CALCULATION DOES NOT DETAIL THE ADDITIONAL
 LOAD, AND THE MATH APPEARS TO BE INCORRECT. IS THE NEW
 LOAD DECREASING BY 109 KVA? THE LOAD CALC SHOWS 481 -
 109 EQUALS 559. THIS MATH IS NOT WORKING. THE LOAD
 CALCULATION SHOULD INCLUDE THE EXISTING DEMAND, AND
 ADDITIONAL 25% OF THE EXISTING DEMAND, PLUS THE
 PROPOSED NEW LOAD TO COMPLY WITH NEC 220.87.
 ADDITIONALLY, PROVIDE PROOF OF STATED FPL LOAD FOR ONE
 YEAR. PROVIDE CORRECTION. NEC 220.87
 4. DEMAND FACTOR APPLIED TO PANEL K IS NOT PER CODE.
 THERE ARE ONLY 5 PIECES OF EQUIPMENT SHOWN IN THE PANEL
 SCHEDULE. THEREFORE, THE DEMAND FACTOR SHOULD BE 70%.
 PROVIDE CORRECTION. NEC 220.56
 5. POWER PLAN SHEET E02.01 DOES NOT SHOW DARKENED LINES
 ON THE NEW REFRIGERATED/FROZEN CASES THAT ARE SHOWN AS
 NEW ON SHEET EQ01.01. PROVIDE CLARIFICATION/CORRECTIONS
 AS NEEDED. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-05-09 Cont ID  
Sent By pleduc Date 2019-05-09 Time   Rev Time 0.00
Received By pleduc Date 2019-05-08 Time 10:44 Sent To  
Notes
2019-05-09 12:50:17THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET D 1 0.1 - UNDER SPECILATIES, THERE IS AN
 INDICATION OF FIRE ALARM EQUIPMENT/WORK.
  
 ANY WORK ON THE FIRE ALARM SYSTEM/EQUIPMENT SHALL BE
 DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY
 LICENSED FIRE ALARM CONTRACTORS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-10-03 Time   Rev Time 0.00
Received By lmarchan Date 2019-09-11 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-13 Cont ID  
Sent By lmarchan Date 2019-06-13 Time 16:02 Rev Time 0.00
Received By lmarchan Date 2019-04-30 Time 09:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-06-05 Cont ID  
Sent By jwitmer Date 2019-06-05 Time 09:05 Rev Time 0.00
Received By jwitmer Date 2019-06-05 Time 07:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-09-27 Cont ID  
Sent By ccole Date 2019-09-27 Time 11:44 Rev Time 0.00
Received By ccole Date 2019-09-27 Time 11:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-06-05 Cont ID  
Sent By ccole Date 2019-06-05 Time 14:53 Rev Time 0.00
Received By ccole Date 2019-06-05 Time 12:30 Sent To  
Notes
2019-06-05 15:10:541ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19030673
 6/5/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COMMISSIONING OF THE MECHANICAL AND ELECTRICAL
 LIGHTING SYSTEMS IS REQUIRED PER SECTION C408.1 FBC-17
 ENERGY CONSERVATION. SUBMIT A COMMISSIONING PLAN AS
 OUTLINED IN SECTION C408.2.1 AND DESCRIBED IN SECTIONS
 C403.2.2- C408.2.3.3. PLEASE NOTE THAT A COPY OF THE
 COMMISSIONING REPORT SHALL BE SUBMITTED FOR REVIEW AT
 FINAL INSPECTION.
  
 2) A SEPARATE PERMIT IS REQUIRED FOR THE REFRIGERATRION
 WORK- SECTION 107.2.1 WPB. PLEASE REMOVE THE
 REFRIGERATIONS PLANS FROM THE SETS AND RESUBMIT UNDER A
 SEPARATE PERMIT.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-10-03 Cont ID  
Sent By shill Date 2019-10-03 Time 06:33 Rev Time 0.00
Received By shill Date 2019-10-01 Time 17:15 Sent To  
Notes
2019-10-03 16:55:56REVIEWED REMOTELY BY TIM HUNT
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-06-11 Cont ID  
Sent By tklarge Date 2019-06-11 Time 09:20 Rev Time 0.00
Received By tklarge Date 2019-05-23 Time 14:20 Sent To  
Notes
2019-06-10 14:43:301) SHT. A08.01 - DETAIL B1 - SHOW THE CLEAR FLOOR SPACE
 FOR THE LAVATORY AND THE WATER CLOSET.
 2) SHT. A08.01 - DETAIL C 3 - THE TOILET PAPER
 DISPENSER SHALL BE LOCATED A MINIMUM OF 15 INCHES AND A
 MAXIMUM OF 48 INCHES FROM THE FINISH FLOOR.
 3) SHT. A08.01 - DETAIL D3 - THE GRAB BARS SHALL BE
 MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT TO THE
 CENTERLINE.
 4) SHT. P01.02 - IDENTIFY ALL OF THE PLUMBING FIXTURES
 ON ALL OF THE WATER PIPING IAOMETRICS. WPB AMEND. TO
 FBC SEC. 107.2.1.
 5) P01.02 - IDENTIFY THE CONTINUATION POINTS OF THE
 WATER LINES FOR EACH PIPING ISOMETRIC EITHER BY ALPHA
 OR NUMERICAL IDENTIFIERS. AS DRAWN, I CANNOT DETERMINE
 WHERE THE CONTINUATION OF THE WATER LINES START OR END.
 WPB AMEND. TO FBC SEC. 107.2.1.
 6) P01.02 - ALTHOUGH IT IS SHOWN AS EXISTING, PLEASE
 SHOW THE TEMPERATURE AND PRESSURE RELIEF LINE FOR THE
 WATER HEATER AND THE LOCATION OF THE TERMINATION POINT
 OF THE RELIEF LINE.
 7) SHT. P02.02 - IDENTIFY THE CONTINUATION POINTS OF
 THE SANITARY LINES FOR EACH PIPING ISOMETRIC BY EITHER
 ALPHA OR NUMERICAL IDENTIFIERS.WPB AMEND. TO FBC SEC.
 107.2.1.
 8) BACKFLOW PREVENTION DEVICES SHALL BE REQUIRED ON
 BEVERAGE DISPENSERS (ASSE 1022), COFFEE MACHINES AND
 NONCARBONATED BEVERAGE DISPENSERS (ASSE 1022) AND ON
 ANY ICEMAKER.
  
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-10-03 Cont ID  
Sent By shill Date 2019-10-03 Time 06:40 Rev Time 0.00
Received By shill Date 2019-10-03 Time 06:38 Sent To  
Notes
2019-10-03 06:41:21DIGITAL SIGNATURE ISSUED BY IDENTRUST. SIGNATURE IS
 INVALID IN ADOBE BUT VALID IN OTHER PDF READERS; SEE
 AUTHENTICATION IN PROPERTIES.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-06-12 Cont ID  
Sent By jpearson Date 2019-06-12 Time 12:30 Rev Time 0.00
Received By jpearson Date 2019-06-12 Time 12:30 Sent To  
Notes
2019-07-03 11:14:54***CORRECT ALL PAGES BUT ONLY UPLOAD PAGES WHICH CHANGE
 DUE TO CODE RELATED COMMENTS*** [email protected],
 561-805-6724
  
  
2019-06-12 12:30:14DIGITAL SIGNATURE NEEDS TO STATE THAT THE PLAN IS
 DIGITALLY SIGNED AND SEALED OR OTHERWISE COMPLY WITH
 FAC 61G15-23.004. PROVIDE CORRECTIONS FOR ALL
 SIGNATURES. WPB FBC 107.1, 107.2.1
  
  
2019-06-11 09:23:55VALID DIGITAL SIGNATURE ON PLUMBING SHEETS. T.LARGE
2019-06-05 15:12:02MECH DIG/SIGS GOOD.
2019-06-05 09:00:20T01 SHEET, ARCHITECTURAL AND STRUCTURAL SHEETS CHECKED
 FOR SIGNATURES, SHEET A03 SIGNATURE PROCESSING ERROR.
 ERROR DURING SIGNATURE VERIFICATION. JW

Review Stop Z ZONING
Rev No 1 Status P Date 2019-06-13 Cont ID  
Sent By llouie Date 2019-06-13 Time   Rev Time  
Received By llouie Date 2019-06-13 Time   Sent To  
Notes
2019-06-13 14:30:23INTERIOR MODIFICATIONS ONLY.