Plan Review Details - Permit 19030641
Plan Review Stops For Permit 19030641
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By cthroop Date 2019-04-19 Time 10:02 Rev Time 0.00
Received By cthroop Date 2019-04-19 Time 08:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-27 Cont ID  
Sent By cthroop Date 2019-03-27 Time 08:27 Rev Time 0.00
Received By cthroop Date 2019-03-21 Time 15:03 Sent To  
Notes
2019-03-27 08:37:19BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. VALUE INCREASED FROM $6,500 TO $10,100 PER CONTRACT.
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 2. PROVIDE FLOOR PLAN. IDENTIFY ALL LOCATIONS OF WORK.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. IDENTIFY LOCATION OF WINDOW TO BE REPLACED. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. PROVIDE WINDOW SCHEDULE. INCLUDE ROUGH OPENING,
 EXPOSURE AND OPENING DESIGN PRESSURE. FBC 107.3.5.3 ?
 PROVIDE WIND DESIGN LOADS/DESIGN PRESSURES PURSUANT TO
 FBC-R301.2.
  
 5. PROPOSED WINDOW IS NON-IMPACT RATED. PROVIDE SHUTTER
 SCHEDULE. FBC R 301, COMPLETE THE "SCHEDULE FOR
 INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE
 ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS
 EXCEL SPREADSHEET):
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 6. PROVIDE FOUNDATION DETAIL. IF FOUNDATION IS SLAB ON
 GRADE, PROVIDE REPAIRE DETAIL FOR UNDER SLAB PLUMBING
 WORK. IF FOUNDATION IS STEM WALL/FLOOR JOIST, PROVIDE
 HANGER DETAIL FOR PROPOSED PLUMBING. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-03-27 Cont ID  
Sent By cthroop Date 2019-03-27 Time 08:26 Rev Time 0.00
Received By cthroop Date 2019-03-21 Time 15:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-19 Cont ID  
Sent By cthroop Date 2019-04-19 Time 10:03 Rev Time 0.00
Received By cthroop Date 2019-04-16 Time 12:59 Sent To  
Notes
2019-04-17 13:00:01RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-27 Cont ID  
Sent By cthroop Date 2019-03-27 Time 08:37 Rev Time 0.00
Received By cthroop Date 2019-03-13 Time 14:41 Sent To  
Notes
2019-03-14 14:41:13R24

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By cthroop Date 2019-04-19 Time 10:03 Rev Time 0.00
Received By cthroop Date 2019-04-19 Time 08:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-03-27 Cont ID  
Sent By cthroop Date 2019-03-27 Time 08:37 Rev Time 0.00
Received By cthroop Date 2019-03-21 Time 15:03 Sent To  
Notes
2019-03-27 08:46:03PLUMBING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IDENTIFY LOCATION OF KITCHEN AND BATH LAV. ON RISER.
 PLUMBING RISER - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATION SECTION
 107.3.5.3 (12).
  
 2. VENTS REQUIRED AT LAV. AHEAD OF WC AND WASHER. SIZE
 ALL DRAINS, STACKS AND VENTS. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  