| Plan Review Stops For Permit 19030631 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-01 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-01 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-04-18 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-18 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-04-25 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-04-25 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2019-04-25 15:42:23 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | CONTRACT COPY STATES NO OPTIONS DECK, LIGHT, DIAMOND | | | BLUE GUNITE NOT INCLUDED WITH VALUE AND ANY OTHER | | | OPTION INCLUDED SHALL BE INCLUDED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-28 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-28 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2019-03-28 08:21:58 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | POOL PANEL ? | | | | | | WHAT SIZE WIRE TO POOL PANEL, WHAT SIZE POOL PANEL? | | | | | | VALUE FOR WORK TO LOW PLEASE SUBMIT A SIGNED CONTRACT | | | FOR POOL. | | | | | | SUBMIT SPECS FOR POOL LIGHT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-01 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-19 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-04-18 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-14 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-24 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-24 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2019-04-24 11:59:37 | NO VAC LINE SHOWN ON PLAN. REVISION REQUIRED IF VAC | | | LINE IS INSTALLED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-05 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-05 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2019-04-05 13:14:04 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE AND THE SIMPLIFIED TOTAL DYNAMIC HEAD | | | CALCULATION IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS | | | MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING | | | SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER, | | | FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT | | | THE PUMP. | | | | | | 2) PROVIDE MAIN DRAIN DETAIL SHOWINF G.P.M AND THAT | | | THEY COMPLY WITH V.G.B. FBC R 4501.6.6, 4501.21.3 | | | | | | 3) VALUE SEEMS LOW. PROVIDE A SIGNED BONA FIDE | | | CONTRACT.109.3 BUILDING PERMIT VALUATIONS. IF, IN THE | | | OPINION OF THE BUILDING OFFICIAL, THE CLAIMED VALUATION | | | OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-04-18 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-18 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-04-23 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-04-23 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2019-04-23 13:37:02 | PROVISOS | | | | | | 1. POOL EQUIPMENT SHALL BE AT LEAST ONE (1) FOOT FROM | | | THE SIDE PROPERTY LINE. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-03-27 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-03-27 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2019-03-27 09:41:09 | PROVISOS | | | | | | 1. POOL EQUIPMENT SHALL BE AT LEAST ONE (1) FOOT FROM | | | THE SIDE PROPERTY LINE. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|