| Plan Review Stops For Permit 19030580 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-04-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-04-17 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2019-04-03 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-04-03 07:33:49 | PLEASE ADDRESS FIRE COMMENTS. | | | | | | PLEASE PROVIDE WATER, SEWER, STORMWATER | | | ELEVATIONS/SEPARATIONS AT CONFLICT POINTS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2019-03-18 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2019-03-18 |
Time |
|
Sent To |
I |
|
| Notes |
| 2019-03-18 06:42:39 | PLEASE SUBMIT PLANS. | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-18 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-18 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-04-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-04-17 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-25 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-25 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2019-03-25 08:57:31 | PERMIT # 19030580 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED DURING PLAN RESUBMISSION. | | | | | | 2) SHOP DRAWINGS WERE SUBMITTED FOR A DOUBLE CHECK | | | VALVE ASSEMBLY HOWEVER THE INSTALLATION LOCATION FOR | | | THIS ASSEMBLY IS NOT IDENTIFIED ON ANY OF THE DRAWINGS | | | PROVIDED. PLEASE MARK THE LOCATION OF THE DDCV TO | | | ENSURE COMPLIANCE WITH THE | | | REQUIREMENTS OF NFPA 24. | | | | | | 3) PER NFPA 24 SECTION 6.2.1, ALL CONNECTIONS TO | | | PRIVATE FIRE SERVICE MAINS FOR FIRE PROTECTION SYSTEMS | | | SHALL BE ARRANGED IN ACCORDANCE WITH ONE OF THE | | | FOLLOWING SO THAT THEY CAN BE ISOLATED: | | | (1)A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40 | | | FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST | | | INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED | | | CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE | | | BUILDING AS THE HEIGHT OF THE WALL FACING THE POST | | | INDICATOR VALVE. | | | (2) A WALL POST INDICATOR VALVE | | | (3) AN INDICATING VALVE IN A PIT, INSTALLED IN | | | ACCORDANCE WITH SECTION 6.4 | | | (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING | | | VALVE NOT LESS THAN 40 FEET FROM THE BUILDING. | | | (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A | | | BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE | | | SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET | | | BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF | | | THE WALL FACING THE BACKFLOW PREVENTER. | | | (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM | | | ACCESSIBLE FROM THE EXTERIOR | | | (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE | | | ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE | | | AUTHORITY HAVING JURISDICTION | | | | | | 4) JOINT RESTRAINT: PER NFPA 13 & 24, SECTION 10.8.1.1, | | | ALL TEES, PLUGS, CAPS, BENDS, REDUCERS, VALVES, AND | | | HYDRANT BRANCHES SHALL BE RESTRAINED AGAINST MOVEMENT | | | BY USING THRUST BLOCKS OR RESTRAINED JOINT SYSTEMS. | | | | | | 5) CORROSION RESISTANCE: PER NFPA 13 & 24, SECTION | | | 10.8.3.5, AFTER INSTALLATION, RODS, NUTS, BOLTS, | | | WASHERS, CLAMPS, AND OTHER RESTRAINING DEVICES SHALL BE | | | CLEANED AND THOROUGHLY COATED WITH A BITUMINOUS OR | | | OTHER ACCEPTABLE CORROSION-RETARDING MATERIAL. | | | | | | 6) ACCEPTANCE REQUIREMENTS: PER NFPA 13 & 24, SECTION | | | 10.10.2.1.3, UNDERGROUND PIPING, FROM THE WATER SUPPLY | | | TO THE SYSTEM RISER, AND LEAD-IN CONNECTIONS TO THE | | | SYSTEM RISER SHALL BE COMPLETELY FLUSHED BEFORE | | | CONNECTION IS MADE TO DOWNSTREAM FIRE PROTECTION SYSTEM | | | PIPING. THE MINIMUM RATE OF FLOW SHALL BE NOT LESS THAN | | | THE FLOW NECESSARY TO PROVIDE A VELOCITY OF 10 FEET PER | | | SECOND. | | | | | | 7) FLUSHING PAPERS: PER NFPA 13 & 24, SECTION 10.10.1, | | | THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR THE | | | COMPLETING AND SIGNING THE CONTRACTOR?S MATERIAL AND | | | TEST CERTIFICATE(S) SHOWN IN FIGURE 10.10.1. | | | | | | 8) HYDROSTATIC TESTING: PER NFPA 13 & 24, SECTION | | | 10.10.2.2.1 ALL PIPING AND ATTACHED APPURTENANCES | | | SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE | | | HYDROSTATICALLY TESTED AT | | | 200 PSI OR 50 PSI IN EXCESS OF THE SYSTEM WORKING | | | PRESSURE, WHICHEVER IS GREATER, AND SHALL MAINTAIN THAT | | | PRESSURE +/-5 PSI FOR 2 HOURS. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
sathomas |
Date |
2019-03-15 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
sathomas |
Date |
2019-03-15 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2019-03-15 10:47:51 | NO PLANS SUBMITTED IN PACKET. | | | | | | S. THOMAS | | | 561-804-4728 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-04-18 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-18 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-18 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-11 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-21 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-18 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-03-13 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2019-03-14 14:15:12 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-18 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-18 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-03 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-03 |
Time |
17:05 |
Sent To |
I |
|
| Notes |
| 2019-04-03 17:25:55 | | | | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19030580 | | | 4/3/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A SEPARATE PERMIT IS REQUIRED FOR THE BACKFLOW | | | PREVENTER. REQUIREMENTS FOR BACKFLOW PREVENTER | | | PERMITTING CAN BE FOUND UNDER "FORMS" ON THE CITY OF | | | WEST PALM BEACH WEB SITE. THE FORM IS TITLED "BACKFLOW | | | PREVENTION DEVICE PERMIT REQUIREMENTS". FOLLOW THE | | | LINKS TO DEVELOPMENT SERVICES TO FIND FORMS. | | | | | | 2) PLEASE PROVIDE SUBMITTALS FOR THE UNDERGROUND | | | PIPING, PIPE FITTINGS, AND JOINT RESTRAINT SYSTEM . | | | PLEASE NOTE THAT MATERIAL DATA SHEETS SHALL BE PROVIDED | | | TO THE ON-SITE INSPECTOR TO INDICATE CORRECT TORQUE | | | WRENCH SETTINGS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-03-15 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-03-15 |
Time |
13:33 |
Sent To |
ENG |
|
| Notes |
| 2019-03-15 13:33:55 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 NO PLANS | | | | | | CHRIS MONTELLO | | | 8056733 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-18 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-18 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2019-04-18 15:09:28 | PROVISO: ENGINEER TO COMPLY WITH FAC61G15-23.004 | | | EMAIL TO ENGINEER SENT | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-18 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-18 |
Time |
05:46 |
Sent To |
|
|
| Notes |
| 2019-04-18 05:50:30 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENT FROM FIRST REVIEW: | | | | | | 1. CIVIL PAGES ARE DIGITALLY SIGNED BY BRITT L. | | | STEPHENS. SEE FS471, FAC61G15-23.002; A SEAL AND | | | PRINTED LICENSE NUMBER IS REQUIRED. AN IMAGE OF A SEAL | | | IS ACCEPTABLE TO SATISFY BOTH REQUIREMENTS. | | | | | | SECOND REVIEW: | | | | | | IT IS NOT CLEAR IF THE COMMENT WAS PROPERLY CONVEYED TO | | | THE ENGINEER AS THE REPONSE NARRATIVE STATES THAT THIS | | | IS COMMENT #2 FOR ENGINEERING. IT IS ALSO NOT CLEAR IF | | | THE ENGINEER DISAGREES WITH THE COMMENT AS THE RESPONSE | | | STATES "PLEASE SEE THE ATTACHED PLANS WITH REQUESTED | | | SEAL." OF THE 13 PAGES SIGNED BY THE ENGINEER, ONLY TWO | | | NEW PAGES WERE UPLOADED, ALL PAGES ARE DIGITALLY SIGNED | | | BUT LACK A SEAL. | | | | | | PLEASE SEE FAC61G15-23.004 FOR LANGUAGE REQUIRED TO BE | | | INCLUDED IN THE DIGITAL SIGNATURE. | | | | | | AS DISCUSSED WITH BILL DUFFY AND DAVID PELLEGRI, THIS | | | ISSUE WILL NOT DELAY ISSUANCE OF THIS PERMIT, BUT | | | ENGINEER IS TO COMPLY IN THE FUTURE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-04-02 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-02 |
Time |
18:24 |
Sent To |
|
|
| Notes |
| 2019-04-02 18:26:23 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. CIVIL PAGES ARE DIGITALLY SIGNED BY BRITT L. | | | STEPHENS. SEE FS471, FAC61G15-23.002; A SEAL AND | | | PRINTED LICENSE NUMBER IS REQUIRED. AN IMAGE OF A SEAL | | | IS ACCEPTABLE TO SATISFY BOTH REQUIREMENTS. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2019-04-18 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2019-04-18 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2019-04-18 16:17:08 | VERSION 3 OF DRAWING C-600 PASSED ZONING REVIEW. | | | STAMPED BY MARGARITA CRUZ. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2019-04-18 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2019-04-18 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2019-04-17 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2019-04-17 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2019-04-17 13:54:20 | THE CONFLICT HAS NOT BEEN CORRECTED. THERE ARE 3 DATE | | | PALMS, TWO THAT ARE RELOCATED. THIS WAS A CONDITION OF | | | APPROVAL THAT THE 2 PALMS BE PLACED BACK CLOSE TO THEIR | | | ORIGINAL POSITIONS AFTER THE BUILDING WAS CONSTRUCTED, | | | AND THE THIRD PALM WAS TO REMAIN IN PLACE. THE | | | LOCATIONS OF THE WATER AND FIRE LINES NEED TO BE | | | ADJUSTED. PLEASE WORK WITH THE LANDSCAPE ARCHITECT TO | | | RESOLVE THE PROBLEM. | | | ALSO NOTE THAT A SEPARATE PERMIT IS NEEDED FOR | | | LANDSCAPING. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-22 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2019-03-22 |
Time |
10:59 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2019-03-22 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2019-03-22 11:03:19 | FAILED | | | | | | PROVIDE WRITTEN RESPONSE TO COMMENTS. | | | | | | 1) THE PROPOSED NEW FIRE SERVICE AND WATER SERVICE | | | LINES APPEAR TO BE IN DIRECT CONFLICT WITH TWO REQUIRED | | | PALMS. PROVIDE A PLAN SHOWING THE LINES AND THE PALMS | | | WITH ADEQUATE SEPARATION FROM THE PROPOSED AND EXISTING | | | UTILITIES IN THE AREA. COORDINATE WITH YOUR THE | | | LANDSCAPE ARCHITECT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] |
|
|