Plan Review Details - Permit 19030514
| Plan Review Stops For Permit 19030514 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-09 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-05 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-04-09 13:43:05 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLAN PAGE 2 OF 2 HAS ACCESSIBLE PARKING DETAILS AND | | | ASPHALT PAVING DETAILS. THESE ARE NOT PART OF THE SCOPE | | | OF WORK. REMOVE FROM PLAN. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. TEMPRARY PERMITS ARE VALID FOR 180 DAYS. STATE DATE | | | OF INSTALLATION AND DATE OF REMOVAL ON PLAN. | | | [A] 108.1 GENERAL. | | | THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT | | | FOR TEMPORARY STRUCTURES AND TEMPORARY USES. SUCH | | | PERMITS SHALL BE LIMITED AS TO TIME OF SERVICE, BUT | | | SHALL NOT BE PERMITTED FOR MORE THAN 180 DAYS. THE | | | BUILDING OFFICIAL IS AUTHORIZED TO GRANT EXTENSIONS FOR | | | DEMONSTRATED CAUSE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-27 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2019-03-27 14:17:23 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE SITE PLAN INDICATES THE FENCE BLOCKING THE | | | ROASDWAY. | | | | | | THE TRAVLE PATH APPEARS TO BE A FIRE LANE AROUND THE | | | BUILDING AND CANNOT BE BLOCKED, | | | | | | PLEASE MOVE THE FENCE OUT OF THE VEHILCE TRAVEL PATH OR | | | PROVIDE A FULL SITE PLAN SHOWING ALL ACCESS POINTS TO | | | THE BUILDING | | | FOR CONSIDERATION TO BLOCK THE VEHICLE TRAVEL PATH. | | | | | | | | | | | | 2) NO GATES/DOORS ARE LOCATED ALONG THE FENCE LINE. | | | | | | PLEASE PROVIDE A DOOR/GATE ALONG THE CURRENT ACCESS | | | POINT OF THE GENERATOR. | | | | | | | | | | | | 3) WHAT IS THE PURPOSE FOR THE FENCE? | | | | | | | | | | | | | | | 4) HOW LONG WILL THE FENCE BE INSTALLED? | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-04-10 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-26 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-09 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-05 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-04-09 13:48:20 | BUILDING PLAN REVIEW - DIGITAL SIGNATURE AND SEAL | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SIGNATURE AND SEAL OF DESIGN PROFESSIONAL IS | | | INVALID. | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-04-10 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-04-10 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2019-04-10 15:19:19 | TEMPORARY FENCE IS ENCROACHING INTO THE ROW AND | | | BLOCKING PORTION OF THE SIDEWALK. A ROW PERMIT WILL BE | | | NECESSARY. IF APPROVED BY ENGINEERIGN PLEASE RESUBMIT | | | PERMIT FOR TEMPORARY FENCE AND INCLUDE COPY OF THE | | | APPROVED ROW PERMIT. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |