Plan Review Details - Permit 19030507
Plan Review Stops For Permit 19030507
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-11 Cont ID  
Sent By dbattles Date 2019-06-11 Time 14:23 Rev Time 0.00
Received By dbattles Date 2019-06-11 Time 14:22 Sent To  
Notes
2019-06-11 14:31:29PROVISO-
 DEFERRED SUBMITTAL:
 EXTERIOR DOOR PRODUCT APPROVALS.
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE CITY OF WEST PALM BEACH
 BUILDING PLANS EXAMINER PX4191
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By dbattles Date 2019-05-07 Time 11:28 Rev Time 0.00
Received By dbattles Date 2019-05-06 Time 16:16 Sent To  
Notes
2019-05-07 11:29:10****CORRECTIONS****
 W.P.B. PERMIT: 19030507
 REVIEWED: MAY 6, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) 301.1 FBC[EXISTING] GENERAL. THE REPAIR, ALTERATION,
 CHANGE OF OCCUPANCY, ADDITION OR RELOCATION OF ALL
 EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE METHODS
 LISTED IN SECTIONS 301.1.1 THROUGH 301.1.3 AS SELECTED
 BY THE APPLICANT. SECTIONS 301.1.1 THROUGH 301.1.3
 SHALL NOT BE APPLIED IN COMBINATION WITH EACH OTHER.
  - WHICH METHOD IS BEING USED FOR COMPLIANCE?
 (PRESCRIPTIVE,WORK AREA OR PERFORMANCE)
  
 2) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVAL FOR
 EXTERIOR DOORS, OR INDICATE THAT THEY WILL BE A
 DEFERRED SUBMITTAL.
  
 3) 425.1 HYPERBARIC FACILITIES. HYPERBARIC FACILITIES
 SHALL MEET
 THE REQUIREMENTS CONTAINED IN CHAPTER 14 OF NFPA 99.
 (NO RESPONSE REQUIRED)
  
 4) 451.3.4.1 NO DOORS SHALL SWING INTO THE CORRIDOR
 EXCEPT
 THOSE TO SMALL CLOSETS OR SMALL MECHANICAL OR
 ELECTRICAL
 ROOMS THAT CANNOT BE USEFULLY OCCUPIED WITH THE DOORS
 IN THE CLOSED POSITION.
  -VERIFY SWING OF DOOR 101
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2019-08-15 Cont ID  
Sent By jleahy Date 2019-08-15 Time 10:22 Rev Time 0.00
Received By jleahy Date 2019-08-15 Time 10:22 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2019-08-07 Cont ID  
Sent By jleahy Date 2019-08-07 Time 14:19 Rev Time 0.00
Received By jleahy Date 2019-08-07 Time 14:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2019-07-31 Cont ID  
Sent By jleahy Date 2019-07-31 Time 10:06 Rev Time 0.00
Received By jleahy Date 2019-07-31 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-07-03 Cont ID  
Sent By jleahy Date 2019-07-03 Time 09:07 Rev Time 0.00
Received By jleahy Date 2019-07-03 Time 08:53 Sent To  
Notes
2019-07-03 09:08:07SEE COMMENT #6 FROM FIRST PLAN REVIEW JLEAHY
  
 ALL OTHER COMMENTS COMPLIED JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-04-22 Cont ID  
Sent By fgiaquin Date 2019-04-22 Time 07:11 Rev Time 0.00
Received By fgiaquin Date 2019-04-22 Time 05:45 Sent To  
Notes
2019-04-22 07:08:24ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
  
 2. PROVIDE ITEMIZED LOAD CALCULATION SHOWING THE TOTAL
 CALCULATED LOAD BEFORE APPLYING DEMAND FACTORS, THE
 METHOD USED FOR DEMAND FACTORS, AND THE CALCULATED LOAD
 AFTER APPLYING DEMAND FACTORS. FBC 107.2.1 NEC 220.
  
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL NEC 110.9, 110.10
  
 4. PROVIDE CUT SHEETS FOR PRODUCT APPROVAL FOR ALL
 SPECIAL EQUIPMENT. HYPERBARIC CHAMBER, OXYGEN
 DISPENSING MACHINES ETC. FBC 107.2.1 NEC 90.7, 110.2,
 110.3B
  
 5. ARE THERE ANY CLASSIFIED LOCATIONS/ZONES? PLEASE
 PROVIDE DOCUMENTATION STATING WHETHER THERE IS OR IS
 NOT. FBC 107.2.1.
  
 6. VALUE FOR AMOUNT OF WORK SHOWN APPEARS LOW. PROVIDE
 COPY OF SIGNED CONTRACT (SIGNED BY BOTH OWNER AND
 CONTRACTOR).
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By pleduc Date 2019-06-03 Time   Rev Time 0.00
Received By pleduc Date 2019-06-03 Time 13:46 Sent To  
Notes
2019-06-03 13:55:226/3/19
  
 IN AN EFFORT TO MOVE THIS PROJECT FORWARD THE FOLLOWING
 IS REQUIRED:
  
 FIRE SPRINKLER DOCUMENTS ARE REQUIRED OF THE EOR BY
 FLORIDA STATUTE (BELOW) FOR THIS MASTER PERMIT. SHOULD
 THE EOR DEFER THE DESIGN TO A QUALIFIED SUBCONTRACTOR,
 AN OFFICIAL SIGNED AND SEALED LETTER IS REQUIRED UNDER
 THIS MASTER PERMIT.
  
 HOWEVER,
  
 THE DELGATED SUBCONTRACTOR IS REQUIRED TO PROVIDED FIRE
 SPRINKLER DOCUMENTS BY FLORIDA STATUTE (BELOW) WITH
 THIS MASTER PERMIT.
  
 ONCE THE REQUIRED DOCUMENTS ARE PROVIDED, SEPARATE SHOP
 DRAWINGS UNDER SEPARATE PERMIT CAN BE
 DESIGNED/SUBMITTED.
  
 PLEASE TAKE NOTICE
  
 SHOP DRAWINGS SUBMITTED UNDER A SPERATE PERMIT WILL BE
 DENIED UNTIL THE REQUIRED DOCUMENTS ARE SUBMITTED UNDER
 THIS MASTER PERMIT.
  
 1) PER FLORIDA ADMINISTRATIVE CODE SECTION
 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS
 SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER
 SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE
 TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR
 EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN
 DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT
 FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION
 SUCH AS PRE-ENGINEERED SYSTEMS.
  
 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING
 DOCUMENTS.
 (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF
 PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR
 INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING
 PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER?S
 RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31,
 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE AHJ. THE DOCUMENTS SHALL INCLUDE:
 (A) INFORMATION THAT PROVIDES MATERIAL SPECIFICATIONS
 REQUIRED FOR THE SAFE OPERATION OF THE SYSTEM THAT IS A
 RESULT OF ENGINEERING CALCULATIONS, KNOWLEDGE AND
 EXPERIENCE.
 (B) LIST FEDERAL, STATE, MUNICIPAL, AND COUNTY
 STANDARDS, CODES, ORDINANCES, LAWS, AND RULES, WITH
 THEIR EFFECTIVE DATES, THAT THE ENGINEERING DOCUMENTS
 ARE INTENDED TO CONFORM TO.
 (C) INFORMATION, AS DETERMINED BY THE ENGINEER OF
 RECORD, NEEDED FOR THE SAFE AND EFFICIENT OPERATION OF
 THE SYSTEM.
 (D) LIST ENGINEERING DESIGN CRITERIA; REFERENCE PROJECT
 SPECIFIC STUDIES, REPORTS, AND DELEGATED ENGINEERING
 DOCUMENTS.
 (E) IDENTIFY CLEARLY ELEMENTS OF THE DESIGN THAT VARY
 FROM THE GOVERNING STANDARDS AND DEPICT/IDENTIFY THE
 ALTERNATE METHOD USED TO ENSURE COMPLIANCE WITH THE
 STATED PURPOSE OF THESE RESPONSIBILITY RULES.
 (2) ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND
 BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING
 DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR
 CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE
 OF SUCH DOCUMENTS.
 (3) WHEN ELEMENTS OF THE PROJECT ARE SHOWN ON AN
 ENGINEERING DOCUMENT ONLY FOR INFORMATION OR
 CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO
 ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER
 SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS
 RESPONSIBILITY.
 (4) ENGINEERING DRAWINGS SHALL BE LEGIBLE AND CLEARLY
 DEFINE AND DELINEATE THE WORK IN THE PROJECT. THEY MUST
 ALSO COMPLY WITH CHAPTER 61G15-23, F.A.C., SEALS.
 (5) ENGINEERS SHALL CLEARLY NOTE ON ANY PRELIMINARY
 ENGINEERING DOCUMENTS THAT SUCH DOCUMENTS ARE NOT IN
 FINAL FORM, BUT ARE BEING TRANSMITTED TO THE PUBLIC
 AGENCY TO RECEIVE AGENCY REVIEWS, COMMENTS AND
 INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE
 REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES
 WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE
 AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A
 PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR
 AGENCY APPROVAL ACTION ON THE SAME PROJECT.
 SPECIFIC AUTHORITY 471.033(2), 471.008 FS. LAW
 IMPLEMENTED 471.033(1)(G), 471.025(3) FS. HISTORY?NEW
 1-26-93, FORMERLY 21H-30.003, AMENDED 11-13-08.
  
  
 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION
 ENGINEERING
 DOCUMENTS.
 (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS
 SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED
 IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT
 DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE
 WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND
 DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S),
 MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND
 UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE
 SAFEGUARDING OF LIFE, HEALTH OR PROPERTY.
 (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS
 SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE
 ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND
 COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES
 AND STANDARDS, WHERE AVAILABLE.
 (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A
 SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION
 SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENTS.
 (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE
 PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT
 DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT
 AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE
 TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND
 ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT
 SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENTS.
 (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED
 BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE
 FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL
 BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS.
 (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION
 FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM
 ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT
 COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED
 ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER
 OF RECORD FOR THE FIRE PROTECTION SYSTEM.
 (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS,
 SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY
 RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN
 ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS,
 UNLESS SHOWN ON OTHER RELATED DOCUMENTS.
 (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER
 OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION
 IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED
 PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE
 SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR
 OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE
 SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION
 SYSTEM ENGINEERING DOCUMENTS.
 SPECIFIC AUTHORITY 471.008, 471.033(2), FS
 LAW IMPLEMENTED 471.005(7), 471.033(2), FS
 HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED
 4-2-2000, 6-26-01
  
 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION
 SYSTEMS.
 (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT
 ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET,
 DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE
 CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE
 WATER MAINS AND DEDICATED FIRE PROTECTION WATER
 SOURCES.
 (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION
 SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL
 INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN
 APPLICABLE:
 (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER
 SUPPLY AS DEFINED BY 633.021(18) F.S.
 (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE
 CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING
 STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND
 CONCLUSIONS.
 (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA.
 (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE,
 DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR
 EACH SEPARATE 42 HAZARD OCCUPANCY.
 (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS
 MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR
 CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE
 NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM
 DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY
 DEMANDING DESIGN AREA.
 (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE
 FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO
 CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION,
 STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH
 RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND
 LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF
 SERVICE.
 (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE
 POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF
 WATER.
 (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF
 RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER
 SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION
 (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE
 LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY
 WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY
 TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND
 THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE
 PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE
 MEASURES.
 (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND
 DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS
 INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP.
 (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD
 AND INTERIOR FIRE PROTECTION COMPONENTS.
 (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE
 MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL
 DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING
 APPROVAL AND DOCUMENTATION.
 (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE
 INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE
 OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL
 ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE
 CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES.
 SPECIFIC AUTHORITY 471.008, 471.033(2), FS
 LAW IMPLEMENTED 471.005(7), 471.033(2), FS
 HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED
 4-2-2000, 6-26-01, 7-12-05
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-03-18 Cont ID  
Sent By scaldero Date 2019-03-18 Time 10:46 Rev Time 0.00
Received By scaldero Date 2019-03-18 Time 10:12 Sent To  
Notes
2019-03-18 10:46:09PERMIT # 19030507
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED COMMENTS:
  
 1) SHEET T.1 INDICATES THAT THIS BUILDING IS NOT
 CURRENTLY EQUIPPED WITH A FIRE SPRINKLER SYSTEM.
 HOWEVER, SHEET LS.1 (LIFE SAFETY) IDENTIFIES THAT A
 FIRE SPRINKLER SYSTEM WILL BE INSTALLED FOR COVERAGE IN
 ROOMS 128 & 129, ONLY.
 BECAUSE THIS BUILDING DOES NOT CURRENTLY HAVE FIRE
 SPRINKLER SYSTEM INSTALLED, ENGINEERED FIRE ALARM AND
 FIRE SPRINKLER CONSTRUCTION DOCUMENTS ARE REQUIRED FOR
 A GENERAL BUILDING PERMIT.
 AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE
 SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS
 (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS)
 FOR A SUB-PERMIT.
  
 2) PER FLORIDA ADMINISTRATIVE CODE SECTION
 61G15-32.004, FIRE PROTECTION ENGINEERING DOCUMENTS
 SHALL INCLUDE THE POINT OF SERVICE FOR THE WATER
 SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS APPLICABLE
 TO THE PROJECT, CLASSIFICATION OF HAZARD OCCUPANCY FOR
 EACH ROOM OR AREA, SUPPRESSION SYSTEM TYPE, DESIGN
 DENSITIES, WATER SUPPLY DATA (FIRE PUMP DATA, HYDRANT
 FLOW TEST DATA) AND ANY PERFORMANCE BASED INFORMATION
 SUCH AS PRE-ENGINEERED SYSTEMS.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-08-15 Cont ID  
Sent By cmontell Date 2019-08-15 Time 11:34 Rev Time 0.00
Received By cmontell Date 2019-08-15 Time 11:34 Sent To  
Notes
2019-08-14 14:52:11RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-06 Cont ID  
Sent By cmontell Date 2019-08-06 Time 13:16 Rev Time 0.00
Received By cmontell Date 2019-08-06 Time 13:16 Sent To  
Notes
2019-08-06 08:01:29CHRIS MONTELLO'S DESK
2019-07-15 13:09:43C11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-03 Cont ID  
Sent By jleahy Date 2019-07-03 Time 09:08 Rev Time 0.00
Received By jleahy Date 2019-05-28 Time 10:28 Sent To  
Notes
2019-05-30 10:28:42C11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-08 Cont ID  
Sent By cpuell Date 2019-05-08 Time 13:08 Rev Time 0.00
Received By cpuell Date 2019-03-12 Time 14:51 Sent To  
Notes
2019-03-13 14:51:12C07

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-08-21 Cont ID  
Sent By dbattles Date 2019-08-21 Time 14:43 Rev Time 0.00
Received By dbattles Date 2019-08-21 Time 14:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By dbattles Date 2019-05-07 Time 11:29 Rev Time 0.00
Received By dbattles Date 2019-05-07 Time 11:29 Sent To  
Notes
2019-05-07 11:30:21PLEASE PROVIDE VERIFICATION OF PREVIOUS USE AND THAT NO
 CHANGE OF OCCUPANCY IS OCCURING.
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2019-08-15 Cont ID  
Sent By cmontell Date 2019-08-15 Time 11:33 Rev Time 0.00
Received By cmontell Date 2019-08-15 Time 11:33 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2019-08-06 Cont ID  
Sent By cmontell Date 2019-08-06 Time 13:15 Rev Time 0.00
Received By cmontell Date 2019-08-06 Time 13:14 Sent To I
Notes
2019-08-06 13:15:36PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M.1: AHU-1 CANNOT BE HOUSED INSIDE THE
 HYBERBARIC ROOM. REFER TO SECTION 14.2.1.1.7 NFPA 99:
 ROOMS HOUSING CLASS OR CLASS B CHAMBERS SHALL BE FOR
 THE EXCLUSIVE USE OF THE HYPERBARIC OPERATION. AHU-1
 MAY REMAIN AND SERVICE THE HYBERBARIC ROOM EXCLUSIVELY
 BUT THE CURRENT PLAN INDICATES THE UNIT IS SEVICING
 OTHER ROOMS.
  
 CHRIS MONTELLO
 561-805-6733
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-06-27 Cont ID  
Sent By ccole Date 2019-06-27 Time 09:01 Rev Time 0.00
Received By ccole Date 2019-06-18 Time 14:38 Sent To  
Notes
2019-06-27 09:21:251ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19030507
 6/27/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M.1: AHU-1 CANNOT BE HOUSED INSIDE THE
 HYBERBARIC ROOM. REFER TO SECTION 14.2.1.1.7 NFPA 99:
 ROOMS HOUSING CLASS OR CLASS B CHAMBERS SHALL BE FOR
 THE EXCLUSIVE USE OF THE HYPERBARIC OPERATION. AHU-1
 MAY REMAIN AND SERVICE THE HYBERBARIC ROOM EXCLUSIVELY
 BUT THE CURRENT PLAN INDICATES THE UNIT IS SEVICING
 OTHER ROOMS.
  
 2) M.1:THE FIRE DAMPER IN THE 10X8 OXYGEN ROOM EXHAUST
 DUCT IS PROHIBITED PER SECTION 510.7 FBC M. IN
 ACCORDANCE WITH SECTION 510.7.3, THE EXHAUST DUCT SHALL
 BE ENCLOSED IN FIRE-RATED CONSTRUCTION FROM THE POINT
 OF PENETRATION OF THE WALL TO THE OUTLET TERMINAL. THE
 DUCT SHALL BE ENCLOSED IN ACCORDANCE WITH THE FLORIDA
 BUILDING CODE, BUILDING REQUIREMENTS FOR SHAFT
 CONSTRUCTION AND SUCH ENCLOSURE SHALL HAVE A MINIMUM
 FIRE-RESISTANCE RATING OF NOT LESS THAN THE HIGHEST
 FIRE-RESISTANCE-RATED WALL ASSEMBLY PENETRATED. PLEASE
 SEE SECTION 510.9 FOR ALLOWABLE DUCT MATERALS- THE
 CURRENT SPECIFICATION IS NON-COMPLIANT. PLEASE NOTE
 THAT A 2-HR FIRE-RATED HAZARDOUS EXHAUST DUCT WRAP IS
 AN ACCEPTABLE ALTERNATIVE TO A CONSTRUCTED FIRE-RATED
 SHAFT ENCLOSURE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-04-18 Cont ID  
Sent By ccole Date 2019-04-18 Time 11:48 Rev Time 0.00
Received By ccole Date 2019-04-18 Time 11:10 Sent To  
Notes
2019-04-18 14:37:191ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19030507
 4/18/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017FBC
 FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
 NFPA 99- 2015 HEALTH CARE FACILITIES CODE
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET T.1: REFER TO SECTION 425.1 FBC B- ADD THE
 NFPA 99-2015 TO THE LIST OF APPLICABLE CODES LISTED
 UNDER PROJECT DATA.
  
 2) T.1: REFER TO SECTION 14.1.2.1 NFPA-99- PROVIDE THE
 CLASSIFICATION OF THE CHAMBER ON THE PLANS- CLASS A-
 HUMAN MULTIPLE OCCUPANCY.
  
 3) T.1: REFER TO SECTION 14.2.1.2 NFPA 99- A
 HYDAULICALLY CALCULATED AUTOMATIC WET PIPE SPRINKLER
 SYSTEM MEETING THE REQUIRMENTS OF NFPA 13 OR A WATER
 MIST SYSTEM PER NFPA 70 IS REQUIRED FOR THE HYPERBARIC
 AND OXYGEN ROOMS.
  
 4) P.3: REFER TO SECTIONS 14.2.1.4- 14.2.1.5 NFPA 99-
 VERIFY THE MEDICAL OXYGEN SYSTEM MEETS ALL THE
 REQUIREMENTS FOR PIPING AND STORAGE OF THE OXYGEN.
  
 5) M.1: A FIRE DAMPER IS REQUIRED FOR THE WALL DIFFUSER
 PENETRATING THE FIRE-RATED OYXGEN ROOM WALL- SECTION
 607.5.2 FBC M.
  
 6) LS.1, M.1, P.3: REFER TO TABLE 307.1(1) FBC B- THE
 OXYGEN ROOM IS CLASSIFIED AS AN H-3 OCCUPANCY BASED ON
 THE 20, 048 CU. FT. OF OXYGEN BEING STORED IN THE ROOM.
 PLEASE SEE SECTION 510.1 FBC M. AND PROVIDE A HAZARDOUS
 EXHAUST SYSTEM FOR THE ROOM. SHOW THE EXHAUST DUCT RUN,
 TYPE OF DUCT TO BE USED, AND TERMINATION LOCATION- SEE
 SECTIONS 510.4, 510.6.5, 510.6.7, 510.7, AND 510.9 FBC
 M. A) PROVIDE A ROOF PLAN SHOWING THE LOCATION OF THE
 FAN AND CLEARANCE DISTANCES IN ACCORDANCE WITH SECTION
 501.3.1 FBC M, AND IN ACCORDANCE WITH SECTION 304.11-
 MINIMUM 10' TO ROOF EDGE OR PROVIDE A GUARD. A) REFER
 TO SECTION 9.3.6.5.3 FOR MECHANICAL VENTILATION RATE,
 LOCATION OF EXHAUST INLETS, AND REQUIRED CONTINOUS
 OPERATION- REMOVE THE THERMOSTAT FROM THE PLAN. B)
 PROVIDE A FL. PRODUICT APPROVAL AND/OR MIAMI-DADE NOA
 FOR THE MAKEUP AIR LOUVER IN THE OXYGEN ROOM- SECTION
 9N-03 FAC. THE LOUVER SHALL BE AMCA 550 RATED )401.5
 FBC M), AND MAY REQUIRED A FIRE DAMPER IF IT IS
 DETERMINED THE EXTERIOR WALL HAS TO BE FIRE-RATED.
  
 7) LS.1: THE WALLS ENCLOSING THE OXYGEN ROOM MUST BE
 3-HR FIRE-RESISTANT IN ACCORDANCE WITH TABLE 508.4 FBC
 B.
  
 8) M.1: PROVIDE EQUIPMENT SCHEDULES FOR THE NEW AC
 SYSTEMS, AND SHOW THE LOCATIONS OF THE NEW CONDENSERS-
 TABLE C403.2.3(1) AND SECTION C501.7 FBC EC, AND
 SECTION 107.2.1 WPB.
  
 9) M.1: PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION
 OF THE CONDENSERS AND ROOF FANS- SECION 301.15 FBC M.
  
 10) M.1: PROVIDE CONDENSATE DISPOSAL PLANS FOR THE NEW
 SYSTEMS- SECTION 307.2.1 FBC M.
  
 11) M.1, P.3: SUBMIT PRODUCT DATA SHEETS FOR THE
 HYPERBARIC CHAMBERS- SECTION 304.1 FBC M.
  
 12) M.1, P.3: REFER TO SECTION 5.1.3.1.1 & 5.1.3.1.2-
 PROVIDE PRODUCT SPECIFICATION SHEETS FOR THE OXYGEN
 TANKS AND CYLINDERS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop MEDGAS MEDICAL GAS
Rev No 3 Status P Date 2019-07-30 Cont ID  
Sent By jesmith Date 2019-07-30 Time 15:02 Rev Time 0.00
Received By jesmith Date 2019-07-30 Time 14:57 Sent To  
Notes
2019-07-30 15:02:36COMMEMTS: MED GAS APPROVED
  

Review Stop MEDGAS MEDICAL GAS
Rev No 2 Status F Date 2019-06-19 Cont ID  
Sent By jesmith Date 2019-06-19 Time 13:36 Rev Time 0.00
Received By jesmith Date 2019-06-19 Time 13:18 Sent To  
Notes
2019-06-19 13:36:30CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 99
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
 MED GAS COMMEMTS: DENIED
 ORIGINAL COMMENTS
 1. NOTE ON THE PLAN THE MED GAS CONTRACTOR AND THE
 INSTALLERS SHALL PROVIDE PROOF OF COMPLIANCE WITH FAC
 61G4-15.031(1)(4)(A)(B)
 A. COMMENT WAS SATISFACTORILY RESPONDED TO.
 2. PROVIDE A DETAIL FOR RESTRAINTS ON THE OXYGEN TANK
 INCLUDING WALL ANCHORAGE. PER WPB AMEND TO FBC 107.2.1
 A. COMMENT WAS SATISFACTORILY RESPONDED TO.
 3. PROVIDE PIPING DETAIL FOR ALL CONNECTION OF THE MED
 GAS SYSTEM. PER WPB AMEND TO FBC 107.2.1
 A. EQUIPMENT SPECIFICATIONS DO PROVIDE GENERIC DETAILS
 FOR CONNECTIONS, BUT DO NOT ADDRESS THE DISTRIBUTION
 AND CONFIGURATIONS OF THIS EQUIPMENT LAY OUT THAT IS
 NEEDED TO GUIDE THE CONTRACTOR AND INSTALLERS AS WELL
 AS ALLOWING THE INSPECTOR TO INSPECT FOR NFPA 99
 COMPLIANCE AND TO CONFIRM THAT THE INSTALLATION
 CONFORMS TO THE DESIGNER?S INTENT. PER WPB FBC 107.2.1,
 PROVIDE DETAIL S ON THE PLAN THAT CLEARLY INDICATE THE
 MANIFOLDS AND PIPING DISTRIBUTION AND CONFIGURATIONS
 REQUIRED FOR A COMPLETE INSTALLATION. THIS INCLUDES A
 RISER DIAGRAM.
 4. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION
 GUIDES FOR ALL MED GAS EQUIPMENT. PER WPB AMEND TO FBC
 107.2.1
 A. REQUIRE ADDITIONAL INFORMATION; THE EQUIPMENT
 SPECIFICATIONS AND CUT SHEETS SHALL BE IDENTIFIED IN A
 WAY THAT MATCHES THEM TO THE PLAN. IDENTIFY APPLICABLE
 OPTIONS ON THE CUT SHEETS AND CROSS OUT OPTIONS NOT
 USED
 NEW COMMENT
 1. THE HYPERBARIC CHAMBER SUPPLIER REQUIRES THAT THE O2
 SUPPLY LINE SHALL BE PROVIDED WITH AN INSTALLED AND
 CERTIFIED O2 SUPPLY OUTLET CONNECTION WITH PRESSURE
 GAUGE (SET BETWEEN 50 AND 90 PSIG) AND SHUT OFF VALVE.
 PROVIDE DETAIL AND SPECS FOR THE SAME.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19030507 2580 METROCENTRE BLVD W # 6
  
  
  

Review Stop MEDGAS MEDICAL GAS
Rev No 1 Status F Date 2019-04-15 Cont ID  
Sent By gjohnson Date 2019-04-15 Time 10:54 Rev Time 0.00
Received By gjohnson Date 2019-04-15 Time 10:54 Sent To  
Notes
2019-04-15 11:18:561ST REVIEW: 19030507
  
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 MED GAS COMMENTS:
  
 1. NOTE ON THE PLAN THE MED GAS CONTRACTOR AND THE
 INSTALLERS SHALL PROVIDE PROFF OF COMPLIANCE WITH FAC
 61G4-15.031(1)(4)(A)(B)
  
 2. PROVIDE A DETAIL FOR RESTRAINTS ON THE OXYGEN TANK
 INCLUDING WALL ANCHORAGE. PER WPB AMEND TO FBC 107.2.1
  
 3. PROVIDE PIPING DETAIL FOR ALL CONNECTION OF THE MED
 GAS SYSTEM. PER WPB AMEND TO FBC 107.2.1
  
 4. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTILLATION
 GUIDES FOR ALL MED GAS EQUIPMENT. PER WPB AMEND TO FBC
 107.2.1
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-08-06 Cont ID  
Sent By jesmith Date 2019-08-06 Time 08:00 Rev Time 0.00
Received By jesmith Date 2019-08-06 Time 07:50 Sent To  
Notes
2019-08-06 07:59:59PLUMBING COMMEMTS: APPROVED

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-06-19 Cont ID  
Sent By jesmith Date 2019-06-19 Time 13:18 Rev Time 0.00
Received By jesmith Date 2019-06-19 Time 13:17 Sent To  
Notes
2019-06-19 13:17:59PLUMBING COMMEMTS: APPROVED
 PROVISO
 1. SEE REDLINED NOTE ON P.2 WATER RISER DIAGRAM; WATER
 HEATER. REFER TO P.4 DETAIL
 2. SEE REDLINED COMMENT ON P.4 AT WATER HEATER DETAIL
 REQUIRING AN AIR GAP FOR THE T&P RELIEF DISCHARGE LINE
  
 19030507 2580 METROCENTRE BLVD W # 6
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-15 Cont ID  
Sent By gjohnson Date 2019-04-15 Time 10:54 Rev Time 0.00
Received By gjohnson Date 2019-04-12 Time 14:51 Sent To  
Notes
2019-04-15 11:31:151ST REVIEW: 19030507
  
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. INDICATE ON THE PLAN THE CODES THAT THIS PROJECT
 SHALL COMPLY WITH FLORIDA BUILDING CODE PLUMBING,
 ACCESSIBILITY AND NFPA 99
  
 2. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5
  
 3. PROVIDE PIPING DETAIL FOR WATER HEATER. PER WPB
 AMEND TO FBC 107.2.1
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2019-06-13 Time   Rev Time 0.00
Received By pgreilic Date 2019-06-13 Time 13:00 Sent To  
Notes
2019-06-13 13:00:541.) LANDSCAPE PERMIT REQUIRED
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By pgreilic Date 2019-05-08 Time   Rev Time 0.00
Received By pgreilic Date 2019-05-08 Time 11:27 Sent To  
Notes
2019-05-08 11:28:281.) PROVIDE SURVEY OR SITE PLAN WITH A NOTE INDICATING
 BUILDING FOOTPRINT WILL NOT BE EXPANDED
 2.) LANDSCAPE PERMIT REQUIRED
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]