Plan Review Details - Permit 19030505
Plan Review Stops For Permit 19030505
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-05-02 Cont ID  
Sent By rmcdouga Date 2019-05-02 Time 08:29 Rev Time 0.00
Received By rmcdouga Date 2019-05-02 Time 08:29 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-04-23 Cont ID  
Sent By rmcdouga Date 2019-04-23 Time 06:32 Rev Time 0.00
Received By rmcdouga Date 2019-04-23 Time 06:05 Sent To I
Notes
2019-04-23 06:33:57PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ADDRESS PLUMBING COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-04-01 Cont ID  
Sent By rmcdouga Date 2019-04-01 Time 09:44 Rev Time 0.00
Received By rmcdouga Date 2019-04-01 Time 09:44 Sent To I
Notes
2019-04-01 09:44:54PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SEE PLUMBING COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2019-03-26 Cont ID  
Sent By jleahy Date 2019-03-26 Time 15:02 Rev Time 0.00
Received By jleahy Date 2019-03-26 Time 15:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-02 Cont ID  
Sent By rmcdouga Date 2019-05-02 Time 08:29 Rev Time 0.00
Received By rmcdouga Date 2019-04-26 Time 15:01 Sent To  
Notes
2019-04-29 15:01:48RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-23 Cont ID  
Sent By rmcdouga Date 2019-04-23 Time 06:32 Rev Time 0.00
Received By rmcdouga Date 2019-04-12 Time 13:12 Sent To  
Notes
2019-04-16 13:12:19RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-01 Cont ID  
Sent By rmcdouga Date 2019-04-01 Time 09:45 Rev Time 0.00
Received By rmcdouga Date 2019-03-12 Time 15:08 Sent To  
Notes
2019-03-13 15:08:10ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-04-30 Cont ID  
Sent By thunt Date 2019-04-30 Time 07:22 Rev Time 0.00
Received By thunt Date 2019-04-30 Time 07:22 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-04-22 Cont ID  
Sent By thunt Date 2019-04-22 Time 14:20 Rev Time 0.00
Received By thunt Date 2019-04-22 Time 14:20 Sent To  
Notes
2019-04-22 14:22:12PLUMBING 2ND REVIEW**DENIED**
  
 1) PROVIDE PLAN SHOWING EXISTING POOL IS EITHER ALREADY
 COMPLYING WITH OR THAT YOUR PLAN ON MODIFICATION TO
 MAKE IT COMPLY WITH THE FOLLOWING SECTIONS:FBC 454.1
  
 454.1.10.1.1 THE LIP OF THE GUTTER MUST BE LEVELED TO
 WITHIN 1/4 INCH (6.4 MM) BETWEEN THE HIGHEST AND LOWEST
 POINT AND THE DOWNWARD SLOPE FROM THE LIP TO THE DRAIN
 MUST BE MAINTAINED AS ORIGINALLY DESIGNED OR INCREASED,
 BUT SHALL NOT EXCEED NEW CONSTRUCTION STANDARDS.
  
 454.1.10.1.2 TILE STEP MARKINGS MUST BE INSTALLED
 MEETING THE REQUIREMENTS OF SECTION 454.1.2.5.3.
  
 454.1.10.1.3 WHERE APPLICABLE THE SLOPE BREAK MARKING
 MUST BE INSTALLED MEETING THE REQUIREMENTS OF SECTION
 454.1.2.2.3.2 AND SAFETY LINE MUST BE INSTALLED 2 FEET
 (610 MM) BEFORE THE MARKING.
  
 454.1.10.1.4 DEPTH MARKERS AND NO DIVING MARKERS MUST
 BE INSTALLED IN ACCORDANCE WITH SECTION 454.1.2.3.
  
 454.1.10.1.5 THE POOL LADDER MUST HAVE A 3 TO 6 INCH
 (76 TO 152 MM) CLEARANCE FROM THE POOL WALL. NEW CROSS
 BRACED LADDER(S) SHALL BE INSTALLED IN PLACE OF NON
 CROSS-BRACED LADDER(S) IN CONFORMANCE WITH SECTION
 454.1.2.5.1 DURING A POOL RESURFACING.
  
 454.1.10.1.6 SHOULD RESURFACING WORKS AFFECT THE STEP
 RISER HEIGHTS, NO RISER SHALL EXCEED 10 INCHES (254 MM)
 FOR POOLS AND 12 INCHES (305 MM) FOR SPAS, AND THE
 INTERMEDIATE RISERS SHALL BE MADE UNIFORM.
  
 454.1.10.1.7 STEP TREADS THAT PROTRUDE FROM THE POOL
 WALL SHALL BE REMOVED AND REPLACED WITH A CROSS-BRACED
 LADDER OR RECONSTRUCTED TO MEET THE REQUIREMENTS OF
 SECTIONS 454.1.2.5.1 OR 454.1.2.5.2.
  
 2) PROVIDE PLUMBING ISO METRIC DRAWING SHOWING THE MAIN
 DRAIN IS ALEAST 5" PER INSTALLATION MANUAL PROVIDE FOR
 THE MAIN DRAIN. FBC 107.2.1
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-03-22 Cont ID  
Sent By tklarge Date 2019-03-22 Time 05:25 Rev Time 0.00
Received By tklarge Date 2019-03-22 Time 04:36 Sent To  
Notes
2019-03-22 05:25:181) SUBMIT TWO COPIES OF A LEGIBLE SITE PLAN. WPB AMEND.
 TO FBC SEC. 107.2.1.
 2) SUBMIT TWO COPIES OF A NARRATIVE THAT CLEARLY
 OUTLINES THE ENTIRE SCOPE OF WORK TO BE DONE. WPB
 AMEND. TO FBC SEC. 107.2.1.
 3) THE NARRATIVE SHALL CLEARLY STATE IF ANY WORK IS
 BEING DONE TO THE MAIN DRAIN OR POOL PIPING SYSTEM. WPB
 AMEND. TO FBC SEC. 107.2.1.
 4) RESURFACING SHALL ADDRESS THE ITEMS LISTED IN 2017
 FBC-BUILDING SEC. 454.1.10.1.1 THROUGH SEC.
 454.1.10.1.7.
 5) SUBMIT A COPY OF THE PALM BEACH COUNTY HEALTH
 DEPARTMENT POOL RESURFACING NOTIFICATION FORM APPROVED
 BY THE DEPARTMEENT.
 6) SUBMIT A COPY OF THE PBC HEALTH DEPT. FORM DH4159
 (OPERATING PERRMIT) SIGNED AND STAMPED BY PBC HEALTH
 DEPT.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By mcruz Date 2019-04-19 Time 11:55 Rev Time 0.00
Received By mcruz Date 2019-04-19 Time 11:53 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-03-20 Cont ID  
Sent By mcruz Date 2019-03-20 Time 13:19 Rev Time 0.00
Received By mcruz Date 2019-03-20 Time 13:16 Sent To  
Notes
***NONE***