Plan Review Details - Permit 19030470
Plan Review Stops For Permit 19030470
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-13 Cont ID  
Sent By shill Date 2019-05-13 Time 06:59 Rev Time 0.00
Received By shill Date 2019-05-09 Time 14:53 Sent To  
Notes
2021-01-12 12:00:47FIXTURES DID NOT MOVE ELECTRICAL PERMIT NOT REQUIRED
 JLEAHY

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-26 Cont ID  
Sent By jwitmer Date 2019-03-26 Time 12:05 Rev Time 0.00
Received By jwitmer Date 2019-03-26 Time 09:17 Sent To  
Notes
2019-03-26 12:05:022017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19030470
 ADD: 901 45TH ST.
 CONT: WESTBROOKE CORP.
 TEL: 561-395-4126
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MARCH 26TH/ 2019
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION INDICATES THE REMOVAL OF
 SUSPENDED CEILINGS & INSTALL NEW DRYWALL CEILINGS IN 18
 PATENT ROOMS AND ACTIVITY ROOM AT THE IMH BUILDING. THE
 PLANS INCLUDE A LIFE SAFETY SHEET, TEMPORARY ZIP WALL
 CONTAINMENT BARRIER, PHASING SHEETS FOR ROOMS TO BE
 ALTERED, AND SHEET A13.1 A SPECIFICATION SHEET.
 MISSING FROM THE PLANS ARE THE DESIGN CRITERIA FOR
 CEILING SPANS:
  
 2017 FBC-B TABLE 2508.1 STEEL FRAMING FOR GYPSUM BOARD.
  
 1A) SUSPENDED CEILING, SPACING OF HANGER WIRE, DIAMETER
 OF HANGER WIRE, ANCHORAGE TO DECK ABOVE, TYPE OF
 HORIZONTAL CHANNEL, BLACK IRON OR GAL.-STEEL, SIZE AND
 GAUGE OF STEEL, IF HI-HAT CHANNEL (RIGID FURRING
 CHANNEL) IS TO BE USED, SIZE GAUGE, AND SPACING,
 SCREWED OR SADDLE TIED SIMPLE SPAN OR MULTIPLE SPANS,
 AND THE TOTAL UNIFORM LOAD.
  
 1B) SSMA ICBO ER-4943P CEILING SPAN TABLES, FOR STEEL
 STUDS, SECTION (SIZE), THICKNESS (MIL), SPACING, LIVE
 LOADS, DEFLECTION, UNSUPPORTED SPAN, SUPPORTED
 MID-SPAN, SCREW SIZE AND SPACING FOR FRAMING MEMBERS
 AND TO GYPSUM.
  
 1C) 2017 FBC-B TABLE 1604.3 DEFLECTION LIMITATION.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2021-01-12 Cont ID  
Sent By jleahy Date 2021-01-12 Time 11:59 Rev Time 0.00
Received By jleahy Date 2021-01-12 Time 11:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-01 Cont ID  
Sent By jleahy Date 2019-05-01 Time 16:49 Rev Time 0.00
Received By jleahy Date 2019-05-01 Time 16:49 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-03-28 Cont ID  
Sent By jleahy Date 2019-03-28 Time 16:41 Rev Time 0.00
Received By jleahy Date 2019-03-28 Time 16:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-26 Cont ID  
Sent By scaldero Date 2019-04-26 Time 10:14 Rev Time 0.00
Received By scaldero Date 2019-04-26 Time 10:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-03-18 Cont ID  
Sent By scaldero Date 2019-03-18 Time 12:12 Rev Time 0.00
Received By scaldero Date 2019-03-18 Time 12:10 Sent To  
Notes
2019-03-18 12:12:44PERMIT # 19030470
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 APPROVED PROVISO:
  
 1) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) OR IN WRITING (FAX:
 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE
 MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.?
  
 2) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-13 Cont ID  
Sent By shill Date 2019-05-13 Time 06:59 Rev Time 0.00
Received By shill Date 2019-04-22 Time 10:57 Sent To  
Notes
2019-04-23 10:57:53B15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-01 Cont ID  
Sent By hmoser Date 2019-04-01 Time 15:41 Rev Time 0.00
Received By hmoser Date 2019-03-11 Time 10:56 Sent To  
Notes
2019-03-13 10:57:03B06

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2019-05-01 Cont ID  
Sent By hmoser Date 2019-05-01 Time 14:34 Rev Time 0.00
Received By hmoser Date 2019-05-01 Time 14:34 Sent To  
Notes
2021-01-12 10:46:40NO WORK STARTED FOR MECHANICAL. ALL AIR CONDITIONING
 DROPS STAYED THE SAME HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-04-01 Cont ID  
Sent By hmoser Date 2019-04-01 Time 15:41 Rev Time 0.00
Received By hmoser Date 2019-04-01 Time 15:32 Sent To  
Notes
***NONE***