Plan Review Details - Permit 19030441
| Plan Review Stops For Permit 19030441 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-05-14 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-05-14 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2019-05-14 15:42:08 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 3RD PLAN REVIEW DENIED: | | | PLEASE READ THE NOTES LISTED BELOW AND ADDRESS AS | | | REQUIRED. IT IS HELPFUL TO RESPOND IN AN ITEM BY ITEM | | | FORMAT. | | | | | | FBC B 107. THE SUBMITTED PLANS ARE MISSING NECESSARY | | | INFORMATION, SUCH AS: | | | 1.SITE BUILT REQUIREMENTS: | | | A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B. PROVIDE BUILDING PLANS: | | | 1. FLOOR: LIVE LOADS, CONNECTION DETAILS, FOUNDATION | | | DETAILS, & COMPACTION REQUIREMENTS. | | | 2. WALLS: WIND LOADS, BRACING, AND CONNECTION DETAILS. | | | PLEASE CLARIFY: THE PROPOSED BATHROOM APPEARS TO BE | | | COVERING UP AN EXISTING WINDOW AND THE EXISTING REAR | | | WALL APPEARD TO SHOW A NEW SLIDING GLASS DOOR. | | | 3. ROOF FRAMING: DEAD LOADS, WIND LOADS, UPLIFT | | | CAPACITIES; RAFTER SPACING IS QUESTIONABLE CONSIDERING | | | SPAN AND TYPICAL GRADES, ROOF FRAMING TO WALL | | | CONNECTIONS, | | | C. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. | | | E. PROVIDE SITE PLAN WITH SETBACKS FROM PROPERTY LINES. | | | 2. ROOFING: | | | A. ROOFING SUB?PERMIT IS REQUIRED: | | | B. PROVIDE ALL RELATED PRODUCT APPROVALS AND IDENTIFY | | | SYSTEMS TO BE USED. | | | C. PROVIDE DESIGN WIND LOADS FOR ZONE 1, 2, & 3. | | | D. PROVIDE SIGNED AND SEALED CALCULATIONS FOR ZONES 2 & | | | 3 PER RAS 117 OR FM LPDS 1?52. | | | 3. SEPERATE PERMITS REQUIRED: | | | A. ELECTRIC | | | B. PLUMBING | | | 4. VALUATION: | | | THE VALUATION OF THIS PERMIT APPLICATION APPEARS TO BE | | | VERY LOW IN COMPARISON TO SOURCES SUCH AS THE ICC | | | BUILDING VALUATION DATA. PLEASE RE?EVALUATE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-04-04 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-04-04 |
Time |
16:23 |
Sent To |
P |
|
| Notes |
| 2019-04-04 17:33:35 | ***CORRECTIONS*** | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND PLAN REVIEW DENIED: | | | R301.1APPLICATION. | | | BUILDINGS AND STRUCTURES, AND ALL PARTS THEREOF, SHALL | | | BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING | | | DEAD LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS, SNOW | | | LOADS, WIND LOADS AND SEISMIC LOADS AS PRESCRIBED BY | | | THIS CODE. THE CONSTRUCTION OF BUILDINGS AND STRUCTURES | | | IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE SHALL | | | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH | | | THAT MEETS ALL REQUIREMENTS FOR THE TRANSFER OF ALL | | | LOADS FROM THEIR POINT OF ORIGIN THROUGH THE | | | LOAD-RESISTING ELEMENTS TO THE FOUNDATION. BUILDINGS | | | AND STRUCTURES CONSTRUCTED AS PRESCRIBED BY THIS CODE | | | ARE DEEMED TO COMPLY WITH THE REQUIREMENTS OF THIS | | | SECTION. | | | | | | FBC B 107. THE SUBMITTED PLANS ARE MISSING NECESSARY | | | INFORMATION, SUCH AS: | | | | | | 1.SITE BUILT REQUIREMENTS: | | | A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B. PROVIDE BUILDING PLANS: | | | 1. FLOOR: LIVE LOADS, CONNECTION DETAILS, FOUNDATION | | | DETAILS, & COMPACTION REQUIREMENTS. | | | 2. WALLS: WIND LOADS, BRACING, AND CONNECTION DETAILS. | | | PLEASE CLARIFY: THE PROPOSED BATHROOM APPEARS TO BE | | | COVERING UP AN EXISTING WINDOW AND THE EXISTING REAR | | | WALL APPEARD TO SHOW A NEW SLIDING GLASS DOOR. | | | 3. ROOF FRAMING: DEAD LOADS, WIND LOADS, UPLIFT | | | CAPACITIES; RAFTER SPACING IS QUESTIONABLE CONSIDERING | | | SPAN AND TYPICAL GRADES, ROOF FRAMING TO WALL | | | CONNECTIONS, | | | C. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. | | | E. PROVIDE SITE PLAN WITH SETBACKS FROM PROPERTY LINES. | | | | | | 2. ROOFING: | | | A. ROOFING SUB-PERMIT IS REQUIRED: | | | B. PROVIDE ALL RELATED PRODUCT APPROVALS AND IDENTIFY | | | SYSTEMS TO BE USED. | | | C. PROVIDE DESIGN WIND LOADS FOR ZONE 1, 2, & 3. | | | D. PROVIDE SIGNED AND SEALED CALCULATIONS FOR ZONES 2 & | | | 3 PER RAS 117 OR FM LPDS 1-52. | | | | | | 3. SEPERATE PERMITS REQUIRED: | | | A. ELECTRIC | | | B. PLUMBING | | | | | | 4. VALUATION: | | | THE VALUATION OF THIS PERMIT APPLICATION APPEARS TO BE | | | VERY LOW IN COMPARISON TO SOURCES SUCH AS THE ICC | | | BUILDING VALUATION DATA. PLEASE RE-EVALUATE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-13 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-13 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2019-03-13 09:22:40 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC B 107. PLEASE PROVIDE MORE DETAILED INFORMATION ON | | | THE WORK THAT WILL BE COVERED UNDER THIS PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-14 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-14 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2019-05-14 09:01:11 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED TO SHOW WHERE LIGHTS, SWITCHES, AND OUTLETS WILL | | | GO IN THE ADDITION ON A FLOOR PLAN. | | | | | | ANY OTHER WORK TO BE ALSO SHOWN ON FLOOR PLAN |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-04-05 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-04-05 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2019-04-05 17:15:25 | NO ELECTRIC SHOWN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-10 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2019-05-13 12:58:08 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-04-05 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-04-04 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2019-04-04 13:44:49 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-13 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-11 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2019-03-12 11:36:58 | BLDG - $5000 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2019-05-14 15:55:43 | PLUMBING 2ND REVIEW**DENIED**PLUMBING SUB PERMIT | | | REQUIRED**FL ST 553.80 (B)2B WITH RESPECT TO EVALUATION | | | OF DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL | | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | ****NOT ADDRESSED AT ALL****A PLUMBING REVIEW COULD NOT | | | BE PERFORMED DUE TO LACE OF INFORMATION. PROVIDE A | | | COMPLETE PLAN SHOWING WHERE PLUMBING FIXTURE WILL BE | | | LOCATED, DIMENSION OF ROOMS, SANITARY RISER ISOMETRIC | | | DRAWING, AND LIST THE COMPLETE SCOPE OF WORK FOR THIS | | | PROJECT. FBC 107.3.5 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-05 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-05 |
Time |
11:54 |
Sent To |
E |
|
| Notes |
| 2019-04-05 11:54:43 | PLUMBING 1ST REVIEW**DENIED**PLUMBING SUB PERMIT | | | REQUIRED** | | | | | | A PLUMBING REVIEW COULD NOT BE PERFORMED DUE TO LACE OF | | | INFORMATION. PROVIDE A COMPLETE PLAN SHOWING WHERE | | | PLUMBING FIXTURE WILL BE LOCATED, DIMENSION OF ROOMS, | | | SANITARY RISER ISOMETRIC DRAWING, AND LIST THE COMPLETE | | | SCOPE OF WORK FOR THIS PROJECT. FBC 107.3.5 | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | |
|
|
|