| 2019-03-13 11:30:01 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | JOSEAN A. DUPREY E.I., BN, PX |
| | BUILDING PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6716 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | ADDRESS PLUMBING COMMENTS: |
| | |
| | 1) THE REMOVAL OF THE EXISTING TUB AND CONVERTING IT TO |
| | A SHOWER IS NOT PERMITTED UNDER F.A.C WITH OUT A |
| | COMPLETE PLAN BEING PROVIDE SHOWING ALL USABLE BATHROOM |
| | AND KNOWING WHAT DESIGN SPEC WAS USED. FOR SHOWERS |
| | UNDER F.A.C YOU MUST SHOW AND HAVE A 48" X 30" PARALLEI |
| | APPROACH TO THE SHOWER WHICH THE TOILET IS NOT |
| | PERMITTED TO ENCROACH INTO. THE TOILET MUST KEEP THE |
| | 18" CLEARANCE FROM THE TUB/SHOWER. I WOULD ADVISED |
| | CONSULTING A DESIGN PROFESSIONAL WITH FAIR HOUSING |
| | KNOWLEDGE. |
| | |
| | 2) PLANS ARE NOT PERMITTED TO BE DRAWN IN PENCIL. PLANS |
| | MUST BE ON SUITABLE MATERIAL. FBC 107.2.1 |
| | |
| | 3) PROVIDE A PLAN SHOWING THE REQUIRED F.A.C CLEAR |
| | FLOOR SPACES WILL REMAIN. FBC 107.3.5 |
| | |
| | ALSO: |
| | |
| | 1) PROVIDE A PLAN SHOWING COMPLIANCE WITH FBC1210.2.3 |
| | SHOWERS. AND FBC 1210.2.2 GRAB BARS |
| | |
| | SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH |
| | INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, |
| | NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 |
| | INCHES (1829 MM) ABOVE THE DRAIN INLET. |
| | |
| | ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER |
| | DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN |
| | WALLS, SHALL BE INSTALLED AND SEALED TO PROTECT |
| | STRUCTURAL ELEMENTS FROM MOISTURE. |
| | |
| | |
| | |
| | |