Plan Review Details - Permit 19030260
| Plan Review Stops For Permit 19030260 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-06 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2019-05-06 10:46:14 | PROVISO: | | | | | | ROOF SUB-PERMIT IS REQUIRED | | | | | | PROVIDE TRUSS SHOP DRAWINGS TO THE FIELD INSPECTOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-04 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2019-04-04 10:19:01 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE HAS BEEN CHANGED FROM $30,000.00 TO $59,148.00 | | | BASED ON THE LATEST EDITION OF THE ICC BUILDING | | | VALUATION DATA TABLES. | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. CHANGE CODE REFERENCE ON COVER PAGE TO FBC 6TH | | | EDITION. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 3. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF. | | | | | | 4. ROOFING PERMIT REQUIRED. | | | | | | 5. PROVIDE PRODUCT APPROVALS FOR NEW EXTERIOR DOOR. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-03 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-03 |
Time |
08:24 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-28 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-28 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2019-03-28 16:09:27 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | R314.3, FBC 107.2.1 | | | | | | 2) PROVIDE AN OUTLET ON THE REAR OF THE BUILDING | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE | | | INSTALLED OUTDOORS AT THE FRONT AND | | | BACK OF EACH DWELLING UNIT HAVING DIRECT ACCESS TO | | | GRADE LEVEL. BALCONIES, DECKS, AND PORCHES THAT ARE | | | ACCESSIBLE FROM INSIDE OF THE DWELLING UNIT SHALL HAVE | | | AT LEAST ONE RECEPTACLE OUTLET | | | INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK, OR | | | PORCH. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE THE BALCONY, DECK, OR | | | PORCH SURFACE. [210.52(E)] | | | | | | 3) OUTLETS IN LAUNDRY TO BE GFCI PROTECTRD | | | E3902.9 LAUNDRY AREAS. | | | 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES | | | INSTALLED IN LAUNDRY AREAS SHALL HAVE GROUND-FAULT | | | CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. | | | [210.8(A)(9)] | | | | | | 4) OUTLETS IN THE LAUNDRY TO BE AFCI PROTECTED. | | | E3902.16 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE | | | FOLLOWING: [210.12(A)] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-09 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-08 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2019-05-09 08:04:57 | IMPACT FEES ROUTED TO JDUPREY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-06 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-25 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2019-04-26 15:52:25 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-04 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-07 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-09 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-09 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2019-05-09 10:43:15 | MU-2019-014147-0000 | | | $9,585.84 PAID |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-06 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-06 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2019-05-06 10:44:03 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-04 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2019-04-04 10:17:03 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-04-02 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-04-02 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-26 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-26 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2019-03-26 08:09:08 | PLUMBING APPROVED WITH PROVISO: | | | | | | 1) PROVIDE A CODE COMPLANIT SANITRARY ISOMETRIC DRAWING | | | REVISION BY 1ST INSPECTION. | | | | | | 2) WATER HEATER WILL REQUIRED A PAN AND PAN DRAIN THAT | | | DISCHARGES TO THE OUTSIDE |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-06 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-06 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-04 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2019-04-04 10:16:20 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | | SYSTEM COMPONENTS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-03-15 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-03-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
|