Plan Review Details - Permit 19030254
Plan Review Stops For Permit 19030254
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-04-02 Cont ID  
Sent By jduprey Date 2019-04-02 Time 10:52 Rev Time 0.00
Received By jduprey Date 2019-04-02 Time 10:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-03-21 Cont ID  
Sent By jduprey Date 2019-03-21 Time 13:54 Rev Time 0.00
Received By jduprey Date 2019-03-21 Time 13:54 Sent To  
Notes
2019-03-21 14:11:07BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 THE ENGINEERES DESIGN PRESSURES WERE PROVIDED. +66.7;
 -70.3
  
 1. THE SINGLE HUNG WINDOW NOA #17-1114.07 PROVIDE TWO
 OPTIONS. ONE OPTION WITH STANDARD FRAME SILL FOR A WIND
 LOAD OF +60; -80 PSF AND OTHER OPTION WITH HI-RISE
 FRAME SILL FOR A WIND LOAD OF +/-80. THE BUYERS ORDER
 INDICATES THE WINDOW WITH +60; -80 PSF THAT IS NOT
 MEETING THE ENGINEERED WIND LOADS. PLEASE VERIFY. FBC
 107
  
 2. PROVIDE DOORS PRODUCT APPROVAL. FBC 107
  
 3. PROVIDE MULLION PRODUCT APPROVAL. FBC 107

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-08 Cont ID  
Sent By jduprey Date 2019-03-08 Time 15:14 Rev Time 0.00
Received By jduprey Date 2019-03-08 Time 15:13 Sent To  
Notes
2019-03-08 15:36:57BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE THE DESIGN PRESSURE CALCULATIONS APPROVED BY
 AN ENGINEER. FBC 107.3.5.1.1; 1603.1.4

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-04-02 Cont ID  
Sent By jduprey Date 2019-04-02 Time 10:52 Rev Time 0.00
Received By jduprey Date 2019-04-02 Time 10:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-21 Cont ID  
Sent By jduprey Date 2019-03-21 Time 14:15 Rev Time 0.00
Received By jduprey Date 2019-03-15 Time 14:42 Sent To  
Notes
2019-03-18 14:42:19RESUB ROUTED TO JDUPREY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-08 Cont ID  
Sent By jduprey Date 2019-03-08 Time 15:37 Rev Time 0.00
Received By jduprey Date 2019-03-07 Time 09:34 Sent To  
Notes
***NONE***