Plan Review Details - Permit 19030221
Plan Review Stops For Permit 19030221
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-06 Cont ID  
Sent By shill Date 2019-05-06 Time 07:57 Rev Time 0.00
Received By shill Date 2019-05-06 Time 07:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-03-26 Cont ID  
Sent By jwitmer Date 2019-03-26 Time 13:17 Rev Time 0.00
Received By jwitmer Date 2019-03-26 Time 12:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-04-30 Cont ID  
Sent By jpearson Date 2019-04-30 Time 13:49 Rev Time 0.00
Received By jpearson Date 2019-04-30 Time 10:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-04-02 Cont ID  
Sent By ppetty Date 2019-04-02 Time 13:36 Rev Time 0.00
Received By ppetty Date 2019-04-02 Time 13:20 Sent To  
Notes
2019-04-02 13:36:011. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 2. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND
 SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE
 ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS
 471.003(2)(H); 471.025; WPB FBC 107.1
 3. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
 4. THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER
 SPACE STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED
 SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1); FBC RE E3901.4
 5.A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN.
 PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE
 E3703.4, E3901.6
 6. 110.26 PROVIDE WORKING CLEARANCE IN FRONT OF PANEL.
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 PHIL PETTY
 ELECTRICAL PLANS EXAMINER / CHIEF ELECTRICAL INSPECTOR
 561-805-6742
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-16 Cont ID  
Sent By scaldero Date 2019-04-16 Time 10:15 Rev Time 0.00
Received By scaldero Date 2019-04-16 Time 10:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-03-11 Cont ID  
Sent By scaldero Date 2019-03-11 Time 10:15 Rev Time 0.00
Received By scaldero Date 2019-03-11 Time 10:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-06 Cont ID  
Sent By shill Date 2019-05-06 Time 07:58 Rev Time 0.00
Received By shill Date 2019-04-12 Time 14:56 Sent To  
Notes
2019-04-15 14:56:17B27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-02 Cont ID  
Sent By ppetty Date 2019-04-02 Time 13:36 Rev Time 0.00
Received By ppetty Date 2019-03-06 Time 15:06 Sent To  
Notes
2019-03-07 15:06:20B01

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-04-22 Cont ID  
Sent By gjohnson Date 2019-04-22 Time 12:30 Rev Time 0.00
Received By gjohnson Date 2019-04-22 Time 11:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-03-26 Cont ID  
Sent By thunt Date 2019-03-26 Time 09:23 Rev Time 0.00
Received By thunt Date 2019-03-26 Time 09:23 Sent To  
Notes
***NONE***