Plan Review Details - Permit 19030071
Plan Review Stops For Permit 19030071
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-18 Cont ID  
Sent By rmcdouga Date 2019-03-18 Time 09:27 Rev Time 0.00
Received By rmcdouga Date 2019-03-18 Time 08:29 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-05 Cont ID  
Sent By rmcdouga Date 2019-03-05 Time 10:00 Rev Time 0.00
Received By rmcdouga Date 2019-03-05 Time 06:44 Sent To I
Notes
2019-03-05 10:10:26 
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE SYSTEM TYPE AND FASTENING OPTION THAT
 WILL BE USED TO ATTACH THE TPO ON THE FLAT ROOF. FBC
 107.2.1
  
 2) IF THE MAXIMUM DESIGN PRESSURE FOR THE FASTENING
 OPTION IS LESS THAN -63.6 PSF AT THE PERIMETER (ROOF
 ZONE 2) AND -95.7 PSF AT THE CORNERS (ROOF ZONE 3),
 THEN SUBMIT SIGNED AND SEALED RAS 117 CALCULATIONS PER
 GENERAL LIMITATION #7 ON PAGE 24. FBC 107.2.1.1 &
 107.2.1.2

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-18 Cont ID  
Sent By rmcdouga Date 2019-03-18 Time 09:27 Rev Time 0.00
Received By rmcdouga Date 2019-03-14 Time 13:33 Sent To  
Notes
2019-03-15 13:34:08RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-05 Cont ID  
Sent By rmcdouga Date 2019-03-05 Time 10:10 Rev Time 0.00
Received By rmcdouga Date 2019-03-04 Time 10:10 Sent To  
Notes
***NONE***