Plan Review Details - Permit 19030060
Plan Review Stops For Permit 19030060
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-06-24 Cont ID  
Sent By dbattles Date 2019-06-24 Time 09:30 Rev Time 0.00
Received By dbattles Date 2019-06-24 Time 09:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-08 Cont ID  
Sent By dbattles Date 2019-05-08 Time 13:47 Rev Time 0.00
Received By dbattles Date 2019-05-07 Time 11:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-21 Cont ID  
Sent By dbattles Date 2019-03-21 Time 08:31 Rev Time 0.00
Received By dbattles Date 2019-03-15 Time 09:21 Sent To  
Notes
2019-03-21 08:32:26****CORRECTIONS****
 W.P.B. PERMIT: 19030060
 REVIEWED: MARCH 18, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
  
 1) 301.1 FBC[EXISTING] GENERAL. THE REPAIR, ALTERATION,
 CHANGE OF OCCUPANCY, ADDITION OR RELOCATION OF ALL
 EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE METHODS
 LISTED IN SECTIONS 301.1.1 THROUGH 301.1.3 AS SELECTED
 BY THE APPLICANT. SECTIONS 301.1.1 THROUGH 301.1.3
 SHALL NOT BE APPLIED IN COMBINATION WITH EACH OTHER.
  -WHICH METHOD IS BEING USED FOR COMPLIANCE?
 (PRESCRIPTIVE,WORK AREA OR PERFORMANCE)
  
 2) 501 FBC[EXISTING] STATE THE LEVEL OF ALTERATION FOR
 WORK BEING PERFORMED.
  -PLEASE ADD LEVEL OF ALTERATION TO DESIGN DATA.
  
 3) 1017.3 FBC[B] MEASUREMENT. EXIT ACCESS TRAVEL
 DISTANCE SHALL BE MEASURED FROM THE MOST REMOTE POINT
 WITHIN A STORY ALONG THE NATURAL AND UNOBSTRUCTED PATH
 OF HORIZONTAL AND VERTICAL EGRESS TRAVEL TO THE
 ENTRANCE TO AN EXIT. (EXIT COMPONENTS INCLUDE EXTERIOR
 EXIT DOORS AT THE LEVEL OF EXIT DISCHARGE, INTERIOR
 EXIT STAIRWAYS AND RAMPS, EXIT PASSAGEWAYS, EXTERIOR
 EXIT STAIRWAYS AND RAMPS AND HORIZONTAL EXITS)
  
 1006.2.1 FBC TABLE[B] MAXIMUM COMMON PATH OF EGRESS
 TRAVEL DISTANCE.
  
 1029.7 FBC[B] TRAVEL DISTANCE. EXITS AND AISLES SHALL
 BE SO LOCATED THAT THE TRAVEL DISTANCE TO AN EXIT DOOR
 SHALL BE NOT GREATER THAN 200 FEET (60 960 MM) MEASURED
 ALONG THE LINE OF TRAVEL IN NONSPRINKLERED BUILDINGS.
 TRAVEL DISTANCE SHALL BE NOT MORE THAN 250 FEET (76 200
 MM) IN SPRINKLERED BUILDINGS. WHERE AISLES ARE PROVIDED
 FOR SEATING, THE DISTANCE SHALL BE MEASURED ALONG THE
 AISLES AND AISLE ACCESSWAYS WITHOUT TRAVEL OVER OR ON
 THE SEATS.
  
 1029.8 FBC[B] COMMON PATH OF EGRESS TRAVEL. THE COMMON
 PATH OF EGRESS TRAVEL SHALL NOT EXCEED 30 FEET FROM ANY
 SEAT TO A POINT WHERE AN OCCUPANT HAS A CHOICE OF TWO
 PATHS OF EGRESS TRAVEL TO TWO EXITS. EXCEPTIONS:
 -FOR AREAS SERVING LESS THAN 50 OCCUPANTS, THE COMMON
 PATH OF EGRESS TRAVEL SHALL NOT EXCEED 75 FEET.
 -FOR SMOKE-PROTECTED ASSEMBLY SEATING, THE COMMON PATH
 OF EGRESS TRAVEL SHALL NOT EXCEED 50 FEET.
  
 A. STATE THE MAXIMUM COMMON PATH OF TRAVEL ON ONE OR
 ALL LIFE SAFETY SHEETS.
 B. STATE THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE.
 C. SHOW THE MAXIMUM COMMON PATH OF TRAVEL AND MAXIMUM
 EXIT ACCESS TRAVEL DISTANCE ON THE PLANS FOR EACH
 AUDITORIUM BEING OCCUPIED.
 D. SHEET LEGEND ON ALL EGRESS PLANS SHOWS R=3
 REPRESENTS REQUIRED EGRESS UNITS AND P=3 FOR PROVIDED
 EGRESS UNITS. ARE THESE UNITS SUPPOSED TO BE THE NUMBER
 OF EXITS REQUIRED AND PROVIDED?
 WHERE USED ON THE PLANS THE R AND P BECOME EGRESS
 WIDTH. IT APPEARS THAT THE EGRESS WIDTH SHOULD BE IN
 THE TABLE WHERE THE COLUMN STATES EGRESS WIDTH AND THE
 R= AND P= SHOULD BE THE NUMBER OF EXITS AT EACH
 AUDITORIUM.
  
 4) 1013.1 FBC[B] EXIT SIGNS.
  -MARK EXIT SIGNS ON LIFE SAFETY SHEETS.
  
 5) 1004.3 FBC[B] POSTING OF OCCUPANT LOAD. EVERY ROOM
 OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE
 OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A
 CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS
 DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE
 OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE
 MAINTAINED BY THE OWNER OR THE OWNER?S AUTHORIZED
 AGENT.
  -PLEASE ADD NOTE TO PLANS, OR TELL ME WHERE THE NOTE
 IS LOCATED.
  
 6) 1008.3.1 FBC[B] GENERAL. IN THE EVENT OF POWER
 SUPPLY FAILURE IN ROOMS AND SPACES THAT REQUIRE TWO OR
 MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM
 SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING
 AREAS:
 -AISLES.
 -CORRIDORS.
 -EXIT ACCESS STAIRWAYS AND RAMPS.
  
 1008.3.2 FBC[B] BUILDINGS. IN THE EVENT OF POWER SUPPLY
 FAILURE IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF
 EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL
 AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS:
 -INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS.
 -INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS.
 -EXIT PASSAGEWAYS.
 -VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED
 FOR EXIT DISCHARGE IN ACCORDANCE WITH SECTION 1028.1.
 -EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR
 EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE.
  
 1008.3.3 FBC[B] ROOMS AND SPACES. IN THE EVENT OF POWER
 SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL
 AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS:
 -ELECTRICAL EQUIPMENT ROOMS.
 -FIRE COMMAND CENTERS.
 -FIRE PUMP ROOMS.
 -GENERATOR ROOMS.
 -PUBLIC RESTROOMS WITH AN AREA GREATER THAN 300 SQUARE
 FEET
  
 A) I SEE GENERATOR FEEDING PANELS, BUT NOT SURE WHAT
 THOSE PANELS COVER. CAN YOU PLEASE PROVIDE PANEL
 SCHEDULES AND EMERGENCY LIGHTING PLAN TO SHOW
 COMPLIANCE WITH 1008.3.1 ? 1008.3.3.?
 B) WHAT HAPPENS TO MOTORIZED CHAIRS IN POWER FAILURE?
  
 5) THE FOLLOWING ITEMS WILL BE DEFERRED SUBMITTALS (NO
 RESPONSE REQD)
 A. GUARDS/RAILS
 B. INTERIOR FINISH FOR DRAPES/CURTAINS
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-06-22 Cont ID  
Sent By jpearson Date 2019-06-22 Time 17:30 Rev Time 0.00
Received By jpearson Date 2019-06-22 Time 17:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-21 Cont ID  
Sent By jpearson Date 2019-05-21 Time 10:50 Rev Time 0.00
Received By jpearson Date 2019-05-21 Time 10:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-03-08 Cont ID  
Sent By jpearson Date 2019-03-08 Time 15:39 Rev Time 0.00
Received By jpearson Date 2019-03-07 Time 15:08 Sent To  
Notes
2019-03-08 15:39:25CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SHEET E102, ROOM 144 (MOTHERS ROOM) SHOWS A
 RECEPTACLE OUTLET WITHIN 6 FEET OF SINK THAT IS NOT
 GFCI PROTECTED. PROVIDE CORRECTION. NEC 210.8
 2. PROVIDE LOAD CALCULATION FOR PANEL DP2, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30
 3. SHEET E602 AND E603 PANEL SCHEDULES SHOW ONLY THE
 LOADS BEING ADDED. PROVIDE TOTAL LOAD CALCULATION FOR
 EACH PANEL TO CONFIRM THE CAPACITY OF THE PANELS IS
 SUFFICIENT. NEC 220, 408.30
 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC
 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-06-20 Cont ID  
Sent By pleduc Date 2019-06-20 Time   Rev Time 0.00
Received By pleduc Date 2019-06-20 Time 13:08 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-05-10 Cont ID  
Sent By pleduc Date 2019-05-10 Time   Rev Time 0.00
Received By pleduc Date 2019-05-10 Time 11:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-03-13 Cont ID  
Sent By pleduc Date 2019-03-13 Time   Rev Time 0.00
Received By pleduc Date 2019-03-13 Time 09:57 Sent To  
Notes
2019-03-13 10:14:35THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET S 504 & N 001 AND DOTHER LIFE SAFETY SHEETS -
 THERE ARE NO DIMENSIONS OF WIDTH BETWEEN THE SEAT BACK
 AND EXTENDED FOOT REST OF THE RECLINERS.
  
 PER NFPA 101, CH 12
  
 12.2.5.5* AISLE ACCESSWAYS SERVING SEATING NOT AT
 TABLES.
 12.2.5.5.1* THE REQUIRED CLEAR WIDTH OF AISLE
 ACCESSWAYS BETWEEN
 ROWS OF SEATING SHALL BE DETERMINED AS FOLLOWS:
 (1) HORIZONTAL MEASUREMENTS SHALL BE MADE, BETWEEN
 VERTICAL
 PLANES, FROM THE BACK OF ONE SEAT TO THE FRONT OF THE
 MOST
 FORWARD PROJECTION OF THE SEAT IMMEDIATELY BEHIND IT.
 (2) WHERE THE ENTIRE ROW CONSISTS OF AUTOMATIC- OR
 SELF-RISING
 SEATS THAT COMPLY WITH ASTM F 851, STANDARD TEST METHOD
 FOR SELF-RISING SEAT MECHANISMS, THE MEASUREMENT SHALL
 BE
 PERMITTED TO BE MADE WITH THE SEATS IN THE UP POSITION.
 12.2.5.5.2 THE AISLE ACCESSWAY BETWEEN ROWS OF SEATING
 SHALL HAVE
 A CLEAR WIDTH OF NOT LESS THAN 12 IN. (305 MM), AND
 THIS MINIMUM
 SHALL BE INCREASED AS A FUNCTION OF ROW LENGTH IN
 ACCORDANCE WITH
 12.2.5.5.4, 12.2.5.5.5, AND 12.2.5.5.6.
  
 12.2.5.5.5.1 THE 12 IN. (305 MM) MINIMUM CLEAR WIDTH OF
 AISLE
 ACCESSWAY SPECIFIED IN 12.2.5.5.2 SHALL BE INCREASED BY
 0.3 IN. (7.6
 MM) FOR EVERY SEAT OVER A TOTAL OF 14 BUT SHALL NOT BE
 REQUIRED TO
 EXCEED 22 IN. (560 MM).
  
 PLEASE REVIEW AND CORRECT AND PROVIDE THE DIMENSIONS IN
 COMPLIANCE.
  
  
  
 2) SHEET N001 - THERE ARE NO INDICATIONS IF THIS
 PROJECT SCOPE INCLUDES CONTINUED OCCUPANCY OF THE
 REMAINDER OF THE THEATER.
  
 PLEASE REVIEW AND PROVIDE A DETAIL REVIEW OR PLAN
 SHEETS THAT INDICATE IF THE THEATER WILKL REMIAN OPEN
 AND OCCUPIED DURING CONSTRUCTION.
  
 ADDITIOANLLY, PLEASE PROVIDE HOW ALL CURRENT EXITS WILL
 BE MAINTAINED AND PROTECTED DURING ANY PHASING.
  
  
  
 3) SHEET DE108 - COMMENT # 8 INDICATES "RELOCATE FIRE
 ALARM DEVICES".
  
 ALL FIRE ALARM WORK SHALL BE DONE UNDER SEPARATE PERMIT
 AND SHOP DRAWINGS BY CERTIFIED FIRE ALARM CONTRACTORS.
  
 THE FIRE ALARM SHALL BE MAINTAINED AND REMAIN
 FUNCTIONAL DURING ENTIRE CONSTRUCTION PERIOD.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGMENT.
  
  
  
 4) SHEET E 103 - THERE IS INDICATION OF FIRE ALARM WORK
 BUT NO INDICATION OF SHOP DRAWINGS.
 ALL FIRE ALARM WORK SHALL BE DONE UNDER SEPARATE PERMIT
 AND SHOP DRAWINGS BY CERTIFIED FIRE ALARM CONTRACTORS.
  
 THE FIRE ALARM SHALL BE MAINTAINED AND REMAIN
 FUNCTIONAL DURING ENTIRE CONSTRUCTION PERIOD.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGMENT.
  
  
  
  
 5) SHEET A 101 - THERE APPEARS TO BE A SHADED/NEW WALL
 IN THE CONCESSION AREA THAT IS NOT CALLED OUT UNDER KEY
 NOTES, COMMENTS, NOR LEGEND.
  
 PLEASE REVIEW AND CORRECT OR CLARIFY.
  
  
  
  
 6) SHEET A 102 - THERE IS A SHADED/ NEW WALL INDICATED
 IN THE FRONT OF AUDITORIUM 3 THAT IS NOT CALLED OUT
 UNDER KEY NOTES, COMMENTS, NOR LEGEND.
  
 PLEASE REVIEW AND CORRECT OR CLARIFY.
  
  
  
  
 7) ALL APPLICABLE SHEETS - ANY NEW WALL REQUIRES AN
 ELVALUATION FO THE FIRE SPRINKLER SYSTEM FOR CODE
 COMPLIANT COVERAGE.
  
 ANY MODICATION/ADDITION OF THE FIRE SPRINKLER SYSTEM
 SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED
 FIRE SPRINKLER CONTRACTORS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT ON THE SHEET.
  
  
  
 8) SHEET A 104 - THERE ARE SHADED/ NEW WALLS INDICATED
 IN THE FRONT OF AUDITORIUM 7 & 8, AND OTHER AREAS THAT
 ARE NOT CALLED OUT UNDER KEY NOTES, COMMENTS, NOR
 LEGEND.
  
 PLEASE REVIEW AND CORRECT OR CLARIFY.
  
  
  
  
 9) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 10) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-07-02 Cont ID  
Sent By lmarchan Date 2019-07-02 Time 11:01 Rev Time 0.00
Received By lmarchan Date 2019-06-18 Time 16:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-05-21 Time   Rev Time 0.00
Received By cpuell Date 2019-05-03 Time 15:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-21 Cont ID  
Sent By dbattles Date 2019-03-21 Time 08:32 Rev Time 0.00
Received By dbattles Date 2019-03-06 Time 10:24 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-03-21 Cont ID  
Sent By dbattles Date 2019-03-21 Time 08:20 Rev Time 0.00
Received By dbattles Date 2019-03-15 Time 09:21 Sent To  
Notes
2019-03-21 08:20:58NO CHANGE IN OCCUPANCY AND NO CHANGE IN AREA.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-07-02 Cont ID  
Sent By ccole Date 2019-07-02 Time 08:13 Rev Time 0.00
Received By ccole Date 2019-07-02 Time 08:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-05-09 Cont ID  
Sent By ccole Date 2019-05-09 Time 13:06 Rev Time 0.00
Received By ccole Date 2019-05-09 Time 11:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-03-18 Cont ID  
Sent By ccole Date 2019-03-18 Time 11:38 Rev Time 0.00
Received By ccole Date 2019-03-15 Time 17:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-06-28 Cont ID  
Sent By gjohnson Date 2019-06-28 Time 17:20 Rev Time 0.00
Received By gjohnson Date 2019-06-26 Time 12:13 Sent To  
Notes
2019-06-26 12:13:39GPJ TO DO REVIEW.

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-07 Cont ID  
Sent By thunt Date 2019-05-07 Time 14:15 Rev Time 0.00
Received By thunt Date 2019-05-06 Time 16:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-03-18 Cont ID  
Sent By thunt Date 2019-03-18 Time 13:52 Rev Time 0.00
Received By thunt Date 2019-03-15 Time 15:20 Sent To  
Notes
2019-03-18 13:53:03PLUMBING 1ST REVIEW PERMIT # 19030060**DENIED**
  
 1) SHT A106 CALLS OUT GRAB BARS TO BE MOUNTED 33"-36"
 TO THE CENTER LINE OF THE BAR.GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION, 33 INCHES (840 MM)
 MINIMUM AND 36 INCHES (915 MM) MAXIMUM ABOVE THE FINISH
 FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE
 FBC-ACC 609.4\
  
 2) SHT A106 CALLS OUT FOR PAPER DISPENSER 7"-9" TO THE
 CENTER OF A MUILT ROLL HOLDER. THE INTENT OF THE CODE
 IS TO BE CENTERED ON THE 1ST ROLL IN MUILT HOLDER
 UNITS. FBC-ACC 604.9.6
  
 3) BOTH UNISEX TOILET ROOMS ARE MISSING BOTH THE 60"
 CLEAR FLOOR SPACE FOR THE TOILET AND THE 60" TURNING
 SPACE. FBC-ACC 604.3.1**603.2.1. THE URINAL SHALL NOT
 ENCROACH IN THE CLEAR FLOOR SPACE OF THE TOILET.
 FBC-ACC 604.3.2
  
 TIM HUNT
 PLUMBING INSPECTOR/PLUMBING PLAN EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2019-07-03 Cont ID  
Sent By shill Date 2019-07-03 Time 09:33 Rev Time 0.00
Received By shill Date 2019-07-03 Time 09:33 Sent To  
Notes
2019-07-03 09:37:28EMAILED [email protected] REGARDING 3RD PARTY
 SIGNATURE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2019-07-02 Cont ID  
Sent By ccole Date 2019-07-02 Time 11:00 Rev Time 0.00
Received By ccole Date 2019-07-02 Time 11:00 Sent To  
Notes
2019-07-02 08:48:493RD SIGNATURE REVIEW BY CHRISTOPHER L. COLE
 PERMIT #19030060
 7/2/19
  
 1) THE FOLLOWING LIST OF MECHANICAL PLANS DO NOT HAVE
 VALID ELECTRONIC SIGNATURES AND SEALS: M101, M102,
 M103, M104, M701, DM101, DM102, DM103, DM104.
 THE DIGITALLY SIGNED PLANS SHALL ALSO BEAR THIS
 STATEMENT IN ACCORDANCE WITH SECTION 61G15-23.005-
 "THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY
 _________ON DATE________USING A SHA-1 AUTHENTICATION
 CODE." THE CURRENT MECHANICAL PLANS INDICATE THEY ARE
 SIGNED ONLY. IN ADDITION ENGINEERS MAY NOT SELF-CERTIFY
 ELECTRONIC SIGNATURES AND SEALS. CERTIFICATION SHALL BE
 BY A THIRD-PARTY AGENCY.
  
 2) FOR ELECTRICAL SHEETS: PER THE WPB AMENDMENTS TO THE
 FBC, EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND
 SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. THE
 DIGITAL SIGNATURE MUST INCLUDE THE STATEMENT "SIGNED
 AND SEALED" AS PER FAC 61G15-23.004. PROVIDE
 CORRECTION. WPB FBC 107.1; FS 471/481
  
 3) PLEASE REVIEW SIGNATURE REVIEW COMMENTS BELOW BY
 SAMANTHA HILL DATED 5/21/19 AND DYLAN BATTLES DATED
 3/21/19
  
 5/21/19
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE FIRE SPRINKLER PLANS ARE NOT SIGNED AND SEALED,
 FS471.
  
 NOTE THAT THE TITLE BLOCK FOR THE FIRE PROTECTION PAGES
 LACK THE PRINTED NAME, LICENSE NUMBER FOR THE ENGINEER
 AND LACK CERTIFICATE OF AUTHORIZATION FOR ENVIRONETICS
 INC.
  
 OTHER PAGES ARE OK.
  
 2. PLEASE ADVISE WHERE THE CITY PLACE STAMP CAN BE
 LOCATED. BUILDING OFFICIAL'S SUGGESTION IS, IF CITY
 PLACE IS UNABLE TO APPLY A REVIEW STAMP DIGITALLY TO A
 PDF, HAVE CITY PLACE STAMP A REDUCED SIZE PLAN AND
 PERMIT COORDINATOR CAN SCAN AND UPLOAD THE APPROVAL
 INTO "SUPPORTING DOCUMENTS".
  
 PLEASE CONTACT ME IF YOU WISH TO DISCUSS.
  
 3/21/19
 FIRE SPRINKLER (FS) SHEETS NOT DIGITALLY SIGNED.
 WAY FINDING (WF) SHEETS NOT DIGITALLY SIGNED.
 ALL OTHER STRUCTURAL SHEET OK FROM 1ST REVIEW.
 ANY ADDITIONAL SHEETS WIL NEED TO BE
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
2019-06-22 16:34:25FOR ELECTRICAL SHEETS: PER THE WPB AMENDMENTS TO THE
 FBC, EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND
 SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. THE
 DIGITAL SIGNATURE MUST INCLUDE THE STATEMENT "SIGNED
 AND SEALED" AS PER FAC 61G15-23.004. PROVIDE
 CORRECTION. WPB FBC 107.1; FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-05-21 Cont ID  
Sent By shill Date 2019-05-21 Time 06:39 Rev Time 0.00
Received By shill Date 2019-05-21 Time 06:39 Sent To  
Notes
2019-05-21 06:41:16****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE FIRE SPRINKLER PLANS ARE NOT SIGNED AND SEALED,
 FS471.
  
 NOTE THAT THE TITLE BLOCK FOR THE FIRE PROTECTION PAGES
 LACK THE PRINTED NAME, LICENSE NUMBER FOR THE ENGINEER
 AND LACK CERTIFICATE OF AUTHORIZATION FOR ENVIRONETICS
 INC.
  
 OTHER PAGES ARE OK.
  
 2. PLEASE ADVISE WHERE THE CITY PLACE STAMP CAN BE
 LOCATED. BUILDING OFFICIAL'S SUGGESTION IS, IF CITY
 PLACE IS UNABLE TO APPLY A REVIEW STAMP DIGITALLY TO A
 PDF, HAVE CITY PLACE STAMP A REDUCED SIZE PLAN AND
 PERMIT COORDINATOR CAN SCAN AND UPLOAD THE APPROVAL
 INTO "SUPPORTING DOCUMENTS".
  
 PLEASE CONTACT ME IF YOU WISH TO DISCUSS.
  
  
2019-05-07 11:53:14A-SHEETS-OK
 S-SHEETS-OK

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-03-21 Cont ID  
Sent By dbattles Date 2019-03-21 Time 08:21 Rev Time 0.00
Received By dbattles Date 2019-03-15 Time 09:21 Sent To  
Notes
2019-03-21 08:22:42FIRE SPRINKLER (FS) SHEETS NOT DIGITALLY SIGNED.
 WAY FINDING (WF) SHEETS NOT DIGITALLY SIGNED.
 ALL OTHER STRUCTURAL SHEET OK FROM 1ST REVIEW.
 ANY ADDITIONAL SHEETS WIL NEED TO BE
2019-03-18 14:59:05MECHANICAL SHEETS DIGITALLY SIGNED AND SEALED.
2019-03-07 15:08:371ST REVIEW ELECTRICAL SHEETS OK.

Review Stop Z ZONING
Rev No 3 Status P Date 2019-06-24 Cont ID  
Sent By eschneid Date 2019-06-24 Time 16:00 Rev Time 0.75
Received By eschneid Date 2019-06-24 Time 14:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2019-05-16 Cont ID  
Sent By eschneid Date 2019-05-16 Time 16:39 Rev Time 2.50
Received By eschneid Date 2019-05-08 Time 13:47 Sent To  
Notes
2019-05-16 16:39:34FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) ADDITIONAL INFORMATION REQUIRED: SHEET A120 ROOF
 PLAN AND PLFM-1 SHOW NEW EQUIPMENT BEING INSTALLED ON
 THE ROOF. IN ACCORDANCE WITH THE CITYPLACE DRI, PLEASE
 PROVIDE VERIFICATION THAT ALL ROOFTOP MECHANICAL
 EQUIPMENT, INCLUDING BUT NOT LIMITED TO SUCH ITEMS AS
 PUBLIC AND PRIVATE UTILITY SERVICE CONNECTIONS;
 HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS;
 COMMUNICATIONS DEVICES; AND RELATED EQUIPMENT, SHALL BE
 SCREENED FROM PUBLIC VIEW THROUGH ANY COMBINATION OF
 LANDSCAPING, WALLS AND EQUIPMENT LOCATION. PLEASE
 PROVIDE PLANS OR OTHER EVIDENCE THAT THE NEW ROOFTOP
 MECHANICAL EQUIPMENT WILL BE SCREENED FROM PUBLIC VIEW.
 ? STAFF IN CONTACT WITH KATIE NIGHTINGALE OF BRR
 ARCHITECTURE TO GET THIS COMMENT SUFFICIENTLY
 ADDRESSED.
  
 2) SUBJECT TO THE ITEMS LISTED ABOVE, THE PROPOSED
 RENOVATION OF THE AMC CITYPLACE 12 MEETS ZONING
 REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-03-20 Cont ID  
Sent By eschneid Date 2019-03-20 Time 12:07 Rev Time 4.00
Received By eschneid Date 2019-03-20 Time 12:07 Sent To  
Notes
2019-03-20 12:07:37FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 1) PROVIDE EITHER THE CITYPLACE LANDLORD APPROVAL STAMP
 ON THE PLANS OR A SEPARATE LETTER FROM CITYPLACE
 APPROVING THE SPECIFIC PLANS SUBMITTED WITH THIS
 PERMIT.
  
 2) THE CITYPLACE DRI REQUIRES THE TRACKING OF THE
 NUMBER OF CINEMA AND IMAX THEATER SEATS. THE SEATING
 SUMMARY TABLE ON SHEET C001 SHOWS THAT THERE WILL BE A
 REDUCTION IN THE NUMBER OF CINEMA SEATS IN AUDITORIUMS
 1, 2, 3, 5, 6, 7, 8, 9, 10, 11 AND 12, AN ELIMINATION
 OF THE SEATS IN AUDITORIUMS A, B, C, D, E, F, G AND H,
 AND A REDUCTION IN THE NUMBER OF IMAX SEATS IN
 AUDITORIUM 4. PLEASE VERIFY THAT THIS IS CORRECT AS
 STAFF WILL NEED TO UPDATE THE CITYPLACE TRACKING CHART.
  
 3) BASED ON THE SEATING SUMMARY SHOWING ZERO SEATS IN
 AUDITORIUMS A, B, C, D, E, F, G AND H, WHAT WILL BE THE
 NEW USE OF THIS SPACE? IS THERE A PHASE 2 PLAN TO
 INSTALL SEATS AT A LATER DATE?
  
 4) SHEET A120 ROOF PLAN INDICATES THAT THERE IS NEW
 EQUIPMENT BEING INSTALLED ON THE ROOF. IN ACCORDANCE
 WITH THE CITYPLACE DRI, PLEASE PROVIDE VERIFICATION
 THAT ALL ROOFTOP MECHANICAL EQUIPMENT, INCLUDING BUT
 NOT LIMITED TO SUCH ITEMS AS PUBLIC AND PRIVATE UTILITY
 SERVICE CONNECTIONS; HEATING, VENTILATING, AND AIR
 CONDITIONING SYSTEMS; COMMUNICATIONS DEVICES; AND
 RELATED EQUIPMENT, SHALL BE SCREENED FROM PUBLIC VIEW
 THROUGH ANY COMBINATION OF LANDSCAPING, WALLS AND
 EQUIPMENT LOCATION. PLEASE PROVIDE PLANS OR OTHER
 EVIDENCE THAT THE NEW ROOFTOP MECHANICAL EQUIPMENT WILL
 BE SCREENED FROM PUBLIC VIEW.
  
 5) THE EXTERIOR SIGNAGE REQUIRES SEPARATE PERMITS WITH
 PLANS AND MUST COMPLY WITH THE CITYPLACE MASTER SIGN
 PLAN.
  
 6) SUBJECT TO THE ITEMS LISTED ABOVE, THE PROPOSED
 RENOVATION OF THE AMC CITYPLACE 12 MEETS ZONING
 REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  