Plan Review Details - Permit 19030026
Plan Review Stops For Permit 19030026
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-08 Cont ID  
Sent By jgomez Date 2019-03-08 Time 17:28 Rev Time 0.00
Received By jgomez Date 2019-03-08 Time 17:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-04 Cont ID  
Sent By jgomez Date 2019-03-04 Time 17:30 Rev Time 0.00
Received By jgomez Date 2019-03-04 Time 17:10 Sent To  
Notes
2019-03-04 17:30:16RESIDENTIAL (R3) RE-ROOF REVISION, BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (TWO
 COPIES) FOR NAIL ENHANCEMENT AT PERIMETER AND CORNER
 AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE
 OF NOA 18-0919.12 SUBMITTED. NEED THE CALCULATIONS TO
 MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301.1
 FBC-RESIDENTIAL.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-08 Cont ID  
Sent By jgomez Date 2019-03-08 Time 17:28 Rev Time 0.00
Received By jgomez Date 2019-03-08 Time 14:08 Sent To I
Notes
2019-03-08 14:08:19RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-04 Cont ID  
Sent By jgomez Date 2019-03-04 Time 17:30 Rev Time 0.00
Received By jgomez Date 2019-03-01 Time 11:36 Sent To I
Notes
***NONE***