 |
Plan Review Details - Permit 19021335
| Plan Review Stops For Permit 19021335 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-26 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-26 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-17 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-17 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2019-04-17 08:54:38 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | | | | APPLICANT IS CHALLENGING THE VALUE OF THE PROPOSED | | | SCOPE OF WORK | | | | | | VALUE WAS BASED ON THE ICC BUILDING VALUATION DATA | | | PUBLISHED FEB. 2019. THE CALCULATION WAS AS FOLLOWS: | | | 996 SQ. FT. NEW UNDER AIR @ $122.46/SQ.FT. = | | | $121,970.00 | | | 274 SQ. FT. NEW COVERED PORCH @ $48.73 = $ 13,352.00 | | | | | | TOTAL VALUE OF ADDITION - $135,322.00 | | | | | | YOU MAY WRITE A LETTER TO ROBERT BROWN, BUILDING | | | OFFICIAL, CITY OF WPB TO PETITION FOR A REDUCTION IN | | | VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-21 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2019-03-21 14:10:07 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. OWNER DOES NOT QUALIFY FOR OWNER/BUILDER STATUS. | | | OWNER RECIEVES A HOMESTEAD TAX EXEMTION ON A RESIDENCE | | | LOCATED AT 11441 MANATEE BAY LANE, WELLINGTON, FL. | | | CONTRACTOR REQUIRED. | | | | | | 2. VALUE HAS BEEN ADJUSTED FROM $80,000.00 TO | | | $135,322.00 BASED ON THE ICC BUILDING VALUATION DATA | | | PUBLISHED FEB. 2019. | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 3. PROVIDE ENERGY SUBMITTAL. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | | NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | | FOUND IN APPENDIX C. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-15 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-15 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-20 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-20 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2019-03-20 09:47:05 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THE WATER HEATER IS NOT INCLUDED | | | IN PANEL SCHEDULE/LOAD CALC. THE RANGE SHOULD BE | | | CALCULATED AT A MINIMUM OF 8 KW. FOR THE AC/AHU LOAD, | | | IT SHOULD BE 100% OF AC, OR 65% OF AHU. LOAD CALC | | | PROVIDED SHOWS 60%. PROVIDE CORRECTIONS. NEC 215.2, | | | 220, TABLE 220.55, 408.30; FBC RE E3602.2 | | | 2. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | 3. CONDUIT FROM 200 AMP SERVICE DISCONNECT TO INTERIOR | | | PANEL IS REQUIRED TO HAVE AN EQUIPMENT GROUNDING | | | CONDUCTOR. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1. | | | 4. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A | | | TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST | | | ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND | | | NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE | | | INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE E3901.7 | | | 5. THERE IS A CONFLICT ON THE PLAN IN REFERENCE TO AFCI | | | PROTECTION. A BIG BLOCK NOTE CORRECTLY STATES THE CODE. | | | HOWEVER, A SMALLER NOTE ON LEFT OF PLAN UNDER THE TITLE | | | "FOR NEW ELECTRIC ONLY" INCORRECTLY STATES THE CODE | | | REQUIREMENT, STATING THAT KITCHENS DO NOT REQUIRE AFCI. | | | PROVIDE CORRECTION. WPB FBC 107.2.1; NEC 210.12; FBC RE | | | E3902 | | | 6. A NOTE ON LEFT OF PLAN UNDER THE TITLE "FOR NEW | | | ELECTRIC ONLY" STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | | 7. RISER DIAGRAM STATES THAT THE METER AND SERVICE | | | DISCONNECT ARE EXISTING, BUT THE PLAN SHOW THESE AS | | | NEW. PROVIDE CLARIFICATION AND/OR CORRECTION. IF NEW OR | | | BEING REPLACED, PROVIDE AVAILABLE SHORT CIRCUIT | | | CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE | | | POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | | RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, | | | 110.10; FBC RE E3606.3; WPB FBC 107.2.1 | | | 8. PROVIDE LOCATION OF CONDENSING UNITS ON PLAN. | | | PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR SERVICING | | | OF A/C EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER | | | CODE. NEC 210.63; FBC RE E3901.12; WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-17 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-09 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2019-04-10 16:16:53 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-03-26 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-02-27 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-21 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2019-03-21 13:16:53 | MU-2019-005221-000. CT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-17 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-17 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-21 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2019-03-21 14:16:10 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE ENERGY SUBMITTAL. INCLUDE A COMPLETED MANUAL | | | J. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 2. PROVIDE EQUIPMENT SPECIFICATIONS. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-19 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-19 |
Time |
06:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-21 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-03-26 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2019-03-26 |
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |