| Plan Review Stops For Permit 19021315 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-05-08 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-05-08 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-20 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2019-03-21 08:52:32 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. CORRECT CODE INFO ON PAGE G-101 TO STATE FBC 6TH ED. | | | 2017. | | | | | | 2. PROPOSED SQ. FT'G. ON PAGE G-101 STATES 250 SQ. FT. | | | PLAN PAGE A101 STATES 298 SQ. FT. PLEASE CLARIFY. | | | | | | 3. PROVIDE DETAIL FOR NEW CMU WALL ATTACHMENT TO | | | EXISTING COLUMNS. | | | | | | 4. PROVIDE DETAIL OF NEW WINDOW OPENINGS. INCLUDE ROUGH | | | OPENINGS - R.O. | | | | | | 5. DESIGNATE USE OF NEW ROOM. IF A BEDROOM, IDENTIFY | | | EMERGENCY EGRESS. | | | | | | 6. PROVIDE FRAMING DETAIL FOR NEW SHOWER PANS. | | | | | | 7. PROVIDE LOCATION AND SIZE OF ATTIC SCUTTLE. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-05-10 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-05-10 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-05-03 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-05-03 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2019-05-03 10:14:28 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | (S) | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-20 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-20 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2019-03-20 08:00:40 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | (S) | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2019-04-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-24 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-24 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2019-04-24 18:10:48 | SUB GAS PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-19 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-19 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2019-03-19 07:05:18 | GAS 1ST REVIEW**DENIED**NOTE - A COMPREHENSIVE REVIEW | | | COULD NOT BE DONE AT THIS TIME AND ADDITIONAL PLAN | | | REVIEW COMMENTS MAY BE GENERATED UPON THE RE-REVIEW OF | | | SUBMITTED CORRECTIONS. | | | | | | 1) YOU SHOW A NEW GAS TANKLESS WATER HEATER BUT DID NOT | | | SUBMIT ANY PLANS OR SUPPORTING DOCUMENTS FOR A GAS | | | REVIEW. I HAVE INCLUDED A CHECK LIST OF WHAT IS | | | REQUIRED TO SUBMIT FOR A GAS REVIEW. FBC 107.3.5 | | | | | | | | | | | | TIM HUNT | | | PLUMBING INSPECTOR/PLUMBING PLAN EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-05-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-05-02 |
Time |
09:59 |
Sent To |
PC |
|
| Notes |
| 2019-05-02 09:59:49 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION(S): | | | | | | 1. ALL WINDOWS SHALL HAVE CLEAR GLASS OR LOW-E GLASS. | | | 2. ALL DOORS SHALL HAVE CLEAR GLASS OR LOW-E GLASS. | | | | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected] | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-03-07 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-03-07 |
Time |
13:49 |
Sent To |
PC |
|
| Notes |
| 2019-03-07 14:07:28 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. A CERTIFICATE OF APPROPRIATENESS APPLICATION IS | | | REQUIRED TO BE SUBMITTED. THE CASE SHALL BE HEARD BY | | | THE HISTORIC PRESERVATION BOARD. | | | | | | A CERTIFICATE OF APPROPRIATENESS IS A SEPARATE PROCESS | | | FROM THE BUILDING PERMIT PROCESS. PLEASE VISIT - HTTP:/ | | | /WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/PLANNING/FORM | | | S TO OBTAIN A COPY OF THE CERTIFICATE OF | | | APPROPRIATENESS APPLICATION. PLEASE INCLUDE ALL | | | INFORMATION REQUIRED UNDER ?ALL OTHER ADDITIONS? ON | | | PAGE 2. A $100.00 APPLICATION FEE WILL ALSO BE | | | REQUIRED. THE DEADLINES FOR THE HISTORIC PRESERVATION | | | BOARD MEETING CAN BE FOUND ON PAGE 3. THE PROPERTY | | | OWNER MAY BE INTERESTED IN APPLYING FOR AN AD VALOREM | | | TAX EXEMPTION (APPLICATION AVAILABLE AT THE URL ABOVE). | | | THE AD VALOREM TAX EXEMPTION PROGRAM ALLOWS THE | | | EXEMPTION OF UP TO 100 PERCENT OF THE ASSESSED VALUE OF | | | ALL IMPROVEMENTS (INTERIOR AND EXTERIOR) TO HISTORIC | | | PROPERTIES RESULTING FROM RENOVATION, RESTORATION, OR | | | REHABILITATION OF SUCH PROPERTIES. THE EXEMPTION | | | APPLIES ONLY TO CITY AND COUNTY PROPERTY TAXES. ALL | | | OTHER TAXING AUTHORITIES LINE ITEMS WILL GO UP. | | | | | | PLEASE CONTACT STAFF TO DISCUSS PROPOSED ALTERATIONS | | | AND ADDITIONS. | | | | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | | | AARON BORNGRABER | | | HISTORIC PRESERVATION PLANNER | | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | | T: 561-822-1428 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-09 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-16 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-27 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-10 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-10 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2019-05-10 15:46:40 | MU-2019-014557-000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-20 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2019-03-21 08:32:46 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-05-09 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-05-09 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-03-21 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-20 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2019-03-21 09:07:49 | MECHANICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE EQUIPTMENT MAKE AND MODEL ON PLANS. | | | 2. PROVIDE EQUIPMENT MAKE, MODEL AND SPECIFICATIONS ON | | | MANUAL J ENERGY CALCULATIONS. | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 2. IDENTIFY ACCESS TO ATTIC EQUIPMENT. | | | | | | M1305.1.3 APPLIANCES IN ATTICS. | | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 20 FEET (6096 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE NOT LESS THAN 30 INCHES (762 MM) DEEP AND 30 | | | INCHES (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES | | | OF THE APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR | | | ACCESS OPENING DIMENSIONS SHALL BE NOT LESS THAN OF 20 | | | INCHES BY 30 INCHES (508 MM BY 762 MM), AND LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-04-24 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-24 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-24 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2019-04-24 18:11:19 | SUB PLUMBING PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-03-19 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-03-19 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-05-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-05-02 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-03-07 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-03-07 |
Time |
13:49 |
Sent To |
PC |
|
| Notes |
| 2019-03-07 13:49:50 | PLEASE SEE HISTORIC COMMENTS. |
|
|