Plan Review Details - Permit 19021170
| Plan Review Stops For Permit 19021170 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-15 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2019-05-15 14:58:11 | 5/15/19 TALKED TO DENNIS TO GO OVER COMMENTS. HE SAID | | | HE WILL INSTALL APPROVED ASSEMBLY SHOWN ON PAGE 22 OF | | | 27 WITH A MAXIMUM DESIGN PRESSURES OF -82.5PSF. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-10 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-10 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2019-05-10 09:04:22 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FLAT ROOF | | | AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: IF THE | | | SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR | | | ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117 | | | CALCULATIONS ARE REQUIRED. | | | FAC 61G20-3.001. | | | | | | RESPONSE: | | | - FLAT ROOF NOA 18-0919.07 SUBMITTED: CLEARLY MARK | | | WHICH APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO | | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | | R301.1 FBC-RESIDENTIAL. NOTE: IF THE SELECTED ASSEMBLY | | | DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, | | | THEN SIGNED AND SEALED RAS 117 CALCULATIONS ARE | | | REQUIRED. SEE GENERAL LIMITATION #7 ON LAST PAGE OF | | | NOA. | | | NOTE: ASSEMBLIES THAT ARE LIMITED BY GENERAL LIMITATION | | | #9 MAY NOT BE USED IF THE MAXIMUM DESIGN PRESSURES | | | DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | GENERAL LIMITATION #9 DOESN'T ALLOW NAIL ENHANCEMENT. | | | SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-02-27 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-02-27 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2019-02-27 18:49:59 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FLAT ROOF | | | AND CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: IF THE | | | SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR | | | ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117 | | | CALCULATIONS ARE REQUIRED. | | | FAC 61G20-3.001. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-15 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-15 |
Time |
14:56 |
Sent To |
I |
|
| Notes |
| 2019-05-15 14:57:51 | 5/15/19 TALKED TO DENNIS TO GO OVER COMMENTS. HE SAID | | | HE WILL INSTALL APPROVED ASSEMBLY SHOWN ON PAGE 22 OF | | | 27 WITH A MAXIMUM DESIGN PRESSURES OF -82.5PSF. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-05-10 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-05-09 |
Time |
13:20 |
Sent To |
I |
|
| Notes |
| 2019-05-09 13:21:06 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-02-27 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-02-25 |
Time |
13:34 |
Sent To |
I |
|
| Notes |
|
|
|