| Plan Review Stops For Permit 19021148 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-02 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-02 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-21 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-27 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-27 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2019-02-27 16:51:33 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 19021148 | | | REVIEWED: FEBRUARY 27, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | | | | 1. 61G1-16.004 FLORIDA ADMINISTRATIVE CODE. TITLE | | | BLOCK. A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL | | | OR INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS THAT ARE REQUIRED TO BE SIGNED | | | AND SEALED. THE TITLE BLOCK MUST, AT A MINIMUM, CONTAIN | | | THE FOLLOWING INFORMATION: | | | PLEASE RE-PRINT THE COVER PAGE TO INCLUDE THE TITLE | | | BLOCK. | | | | | | 2. 501 FBC[EXISTING] STATE THE LEVEL OF ALTERATION FOR | | | WORK BEING PERFORMED. | | | | | | 3. 501 FBC[EXISTING] PROVIDE EXISTING OCCUPANCY. | | | IF NO CHANGE IN OCCUPANCY, PLEASE STATE OCCUPANCY AS NO | | | CHANGE FROM PREVIOUS. THIS WILL SATISFY THE IMPACT STOP | | | THAT WAS INCLUDED WITH THIS PERMIT REVIEW. | | | | | | 4. 107.5.3 FBC[AMENDED] SHEET A-1 IN CODE INFORMATION | | | THAT IT IS USING 2017 FBC 5TH EDITION. PLEASE CHANGE TO | | | 6TH EDITION. PLEASE ADD LEVEL OF ALTERATION TO DESIGN | | | DATA. | | | | | | 5. 107.5.3 FBC[AMENDED] IS THE BUILDING SPRINKLERED OR | | | NON SPRINKLERED? | | | | | | 6. 107.3.5 FBC[B] REMOVE NOTE #4 IN SCOPE OF ON SHEET | | | A-1 THAT STATES NO CHANGE IN A/C CONFIGURATION. | | | | | | 7. 1005.1 FBC[B] GENERAL. ALL PORTIONS OF THE MEANS OF | | | EGRESS SYSTEM SHALL BE SIZED IN ACCORDANCE WITH THIS | | | SECTION. | | | | | | 8. 1004.1 FBC[B] SHEET A-1 SHOWS 2248 SF @ 1/80 = 74.8 | | | PERSONS. PLEASE REVIEW THIS AS THE OCCUPANT LOAD | | | DOESN'T MATCH WHAT IS PROVIDED IN TABLE 1004.1.2 OR IN | | | NFPA 101. | | | | | | 9. 1004.1 FBC[B] SHEET A-1 IN AREA STATES 1050 SQ. FT | | | AND OCCUPANT LOAD STATES 2248 SQ. FT. PLEASE CLARIFY | | | THE SQ. FOOTAGE AND IF 1050 IS THE AREA OF WORK STATE | | | AS SUCH WITH THE LEVEL OF ALTERATION. | | | | | | 10. 1004.1 FBC[B] PROVIDE LIFE SAFETY TO SHOW NUMBER OF | | | EXITS AND COMMON PATH OF TRAVEL. | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. | | | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE | | | REQUIRED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-02 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-02 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-16 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-16 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2019-03-16 08:51:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. SCOPE OF WPRK NOT CLEAR ON PLAN. MARK WHAT IS | | | EXISTING AND WHAT IS NEW. IF ANY LOAD IS BEING ADDED, | | | PROVIDE LOAD CALCULATION TO CONFIRM SERVICE IS | | | ADEQUATE. IF NO LOAD IS BEING ADDED, STATE THAT ON | | | PLAN. NOTE 5 STATES ALL LIGHTS EXCEPT BATHROOMS TO BE | | | SWITCHED FROM PANEL. IF THERE ARE LIGHTING CHANGES, | | | AUTOMATIC CONTROL OF LIGHT FIXTURES IS REQUIRED PER | | | ENERGY CODE. PROVIDE CLARIFICATION AND/OR CORRECTIONS | | | AS NEEDED. WPB FBC 107.2.1; NEC 220; FBC EC C405.2 | | | (CONFLICT EXIST BETWEEN LETTER PROVIDED AND PLAN. | | | LETTER STATES THAT THE CHANDELIERS ARE BEING ADDED, BUT | | | THE PLAN SHOWS THEM AS EXISTING. PROVIDE CLARIFICATION | | | AND/OR CORRECTION. SHOW LOCATION OF ALL EXISTING ITEMS | | | AS WELL AS NEW ITEMS.) | | | | | | NEW COMMENTS: | | | | | | 2. LOAD CALCULATION PROVIDED IS NOT ACCURATE. THE LOAD | | | CALCULATION SHOULD INCLUDE EXISTING AND NEW LOADS TO | | | CONFIRM CAPACITY OF SERVICE IS ADEQUATE. PLAN STATES AC | | | IS EXISTING, BUT NO LOAD IS SHOWN FOR THAT. INCLUDE ALL | | | LOADS. NEC 215.2, 220, 408.30 | | | 3. SWITCHIHNG OF LIGHT FIXTURES NOT SHOWN. PROVIDE | | | CORRECTION. WPB FBC 107.2.1 | | | 4. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | | 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2019-02-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-28 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-28 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2019-02-28 07:55:11 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SCOPE OF WPRK NOT CLEAR ON PLAN. MARK WHAT IS | | | EXISTING AND WHAT IS NEW. IF ANY LOAD IS BEING ADDED, | | | PROVIDE LOAD CALCULATION TO CONFIRM SERVICE IS | | | ADEQUATE. IF NO LOAD IS BEING ADDED, STATE THAT ON | | | PLAN. NOTE 5 STATES ALL LIGHTS EXCEPT BATHROOMS TO BE | | | SWITCHED FROM PANEL. IF THERE ARE LIGHTING CHANGES, | | | AUTOMATIC CONTROL OF LIGHT FIXTURES IS REQUIRED PER | | | ENERGY CODE. PROVIDE CLARIFICATION AND/OR CORRECTIONS | | | AS NEEDED. WPB FBC 107.2.1; NEC 220; FBC EC C405.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-04-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-04-02 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-03-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-14 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-02-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-02-27 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2019-02-27 11:32:39 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET 1 OF 4 - THERE IS NO ADDRESS OF THE OCCUPANCY | | | ON THIS SHEET. | | | | | | PLEASE PROVIDE THE OCCUPANCY ADDRESS ON THIS SHEET. | | | | | | | | | | | | 2) SHEET 1 OF 4 - THERE IS AN INDICATION OF THIS SHEET, | | | 1 OF 4; HOWEVER, THERE ARE ONLY THREE SHEETS SUBMITTED | | | AND ARE INDICATED AS 2 OF 3 AND 3 OF 3. | | | | | | PLEASE CORRECT TO THE APPLICABLE PAGE(S) SUBMITTED. | | | | | | | | | | | | 3) THERE IS NO REFERNCE TO A FIRE CODE INDICATED ON ANY | | | SHEET. | | | | | | PROPOSED PROJECTS SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE WHICH | | | INCLUDES THE 2015 EDITION OF NFPA 1 AND NFPA 101. | | | | | | | | | PLEASE REIVE AND ENSURE COMPLIANCE AND PROVIDE AN | | | APPLICABLE NOTE UNDER CODE INFORMATION. | | | | | | | | | | | | 3) SHEET 1 OF 4 - THERE IS AN INDICATION OF THE | | | OCCUPANCY CLASSIFICATION AS "B" (BUSINESS); HOWEVER, | | | UNDER THE OCCUPANCY LOAD THERE IS AN INDICATION 1/80. | | | | | | PER THE FFPC, NFPA 101, CH 7, TABLE 7.3.1.2, A BUSINESS | | | OCCUPANCY SHALL CALCULATE AT 1/100. | | | | | | ADDITIONALLY, A STORAGE/OFFICE IS INDICATED AND BASED | | | ON THE INTENDED USE MAY CLACULATE AT 1/200. | | | | | | PLEASE REVIEW AMD CORRECT AS APPLICABLE. | | | | | | | | | | | | 4) SHEET 2 OF 3 - THERE ARE NO EXITS SIGNS INDICATED | | | BUT WILL BE VERIFIED ON INSPECTION IF THEY ARE | | | EXISTING. | | | | | | PER NFPA 101, CH 7 | | | | | | 7.10 MARKING OF MEANS OF EGRESS. | | | 7.10.1 GENERAL. | | | 7.10.1.1 WHERE REQUIRED. MEANS OF EGRESS SHALL BE | | | MARKED IN | | | ACCORDANCE WITH SECTION 7.10 WHERE REQUIRED IN CHAPTERS | | | 11 | | | THROUGH 43. | | | | | | PLEASE ENSURE THAT EXITS ARE PROPERLY MARKED. | | | | | | | | | | | | 5) SHEET 2 OF 3 - A REAR DOOR LEADING INTO A | | | STORAGE/OFFICE SPACE WITH AN EXTERIOR DOOR LEADING OUT | | | OF THE BUILDING IS INDICATED. | | | | | | PER NFPA 101 CH 7 | | | | | | 7.5.2 IMPEDIMENTS TO EGRESS. SEE ALSO 7.1.9 AND | | | 7.2.1.5. | | | 7.5.2.1* ACCESS TO AN EXIT SHALL NOT BE THROUGH | | | KITCHENS, | | | STOREROOMS OTHER THAN AS PROVIDED IN CHAPTERS 36 AND | | | 37, | | | RESTROOMS, CLOSETS, BEDROOMS OR SIMILAR SPACES, OR | | | OTHER ROOMS OR | | | SPACES SUBJECT TO LOCKING, UNLESS PASSAGE THROUGH SUCH | | | ROOMS OR | | | SPACES IS PERMITTED FOR THE OCCUPANCY BY CHAPTER 18, | | | 19, 22, OR 23. | | | | | | AN EXIT SIGN OVER THIS STORAGE/OFFICE DOOR WOULD NOT BE | | | APPLICABLE IF THE ROOM IS USED FOR GENERAL STORAGE. | | | | | | AN EXIT SIGN OVER THE EXTERIOR DOOR WOULD BE | | | APPLICABLE. | | | | | | | | | | | | 6) SHEET 1 OF 4 - THERE IS AN INDICATION LABELD "AREA" | | | 1050 S.F. A/C; HOWEVER, THERE IS A SQ 2248 INDICATED | | | FOR OCCUPANCY. | | | | | | PLEASE REVIEW AND CORRECT OR JUSITFY WHAT THE SQ IS. | | | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-29 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-11 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-03-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-25 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-21 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-21 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-27 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-27 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2019-02-27 16:53:16 | IF NO CHANGE IN OCCUPANCY, THERE WILL BE NO IMPACT | | | FEES. | | | SEE COMMENT IN BUILDING TO SUPPLY EXISTING OCCUPANCY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-02 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-02 |
Time |
16:19 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-15 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-15 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2019-03-15 16:24:41 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #19021148 | | | 3/15/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A3: 2ND REQUEST FOR RETURN AIR FROM THE STUDIOS- | | | SECTION 601.6 FBC M | | | | | | 2) A3: 2ND REQUEST FOR A DUCT SMOKE DETECTOR TO BE | | | INSTALLED IN THE SUPPLY SYSTEM OF THE 5 TON AC SYSTEM. | | | PROVIDE A SYMBOL TO SHOW THE LOCATION- SECTION 606.2.1 | | | FBC M. | | | | | | 3) A3: SHOW THE NEW DRESSING ROOM EXHAUST DUCT RUNS AND | | | TERMINATION LOCATIONS- SECTION 501.3 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-01 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-01 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2019-03-01 10:56:57 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #19021148 | | | 3/1/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A1: REFER TO SECTION 301.1 FBC EX AND INDICATE | | | ON THE PLAN WHICH METHOD OF COMPLIANCE WILL BE USED FOR | | | THE PROPOSED PROJECT. | | | | | | 2) A3: PROVIDE THE TYPES AND SIZES OF NEW DUCTWORK | | | SUPPLYING AIR TO THE STUDIOS AND DRESSING ROOMS- | | | SECTION 603 FBC M. | | | | | | 3) A3: PROVIDE RETURN AIR FROM THE STUDIOS- SECTION | | | 601.6 FBC M | | | | | | 4) A3: PROVIDE EXHAUST FOR THE DRESSING ROOMS AT A RATE | | | OF .25 CFMS PER SF.- SEE TABLE 403.3.1.1 FBC M. | | | | | | 5) A3: A DUCT SMOKE DETECTOR IS REQUIRED IN THE SUPPLY | | | AIR SYSTEM OF THE 5-TON AC SYSTEM PER SECTION 606.2.1. | | | PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED IF THE | | | MANUFACTURER'S SPECIFICATIONS INDICATE SYSTEMS ARE NOT | | | CAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY AIR. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|